Description:
The performances of a wedge-type gas-sampling probe and pitot probes are compared in applications to flowfield profile studies. The flow structure data obtained by these techniques are found to agree well in flow regions with and without significant gradients. The wedge-type probe showed a good service life and allowed a substantial reduction of the sampling time. The wedge probe design is discussed.