The radiation from the 5 cm period undulator at the Advanced Light Source (ALS) has been characterized using a transmission grating spectrometer. Spectral and angular distributions of radiation were measured for deflection parameter K values between 0.45 and 2.12 at low storage ring current (0.1–0.5 mA). From the calibration of the spectrometer, the absolute flux density of the undulator harmonics has been determined together with the spectral linewidth. The electron-beam emittance was determined by analyzing the angular distribution of the redshifted fundamental. Comparison has been made with radiation calculations based upon the measured magnetic-field data of the undulator. Including field errors, electron-beam emittance, and energy spread, good agreement is found between theoretically and experimentally determined harmonic widths and peak brightness. © 1995 American Institute of Physics.