ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Acta crystallographica 55 (1999), S. 243-246 
    ISSN: 1399-0047
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Chemistry and Pharmacology , Geosciences , Physics
    Notes: Solving the phase problem is the crucial and quite often the most difficult and time-consuming step in crystallographic structure determination. The traditional methods of isomorphous replacement (MIR or SIR) and molecular replacement require the availability of an isomorphous heavy-atom derivative or the structure of a homologous protein, respectively. Here, a method is presented which utilizes the low-resolution molecular shape determined from solution X-ray scattering data for the molecular search. The molecular shape of a protein is an important structural property and can be determined directly by the small-angle scattering technique. The idea of locating this molecular shape in the crystallographic unit cell has been tested with experimental diffraction data from nitrite reductase (NiR). The conventional Patterson search proved to be unsuccessful, as the intra-envelope vectors are uniformly distributed and do not match those of intra-molecular (atom-to-atom) vectors. A direct real-space search for orientation and translation was then performed. A self-rotation function using 2.8 Å crystallographic data yielded the polar angles of the non-crystallographic threefold axis. Knowledge of the orientation of this axis reduces the potential six-dimensional search to four (Eulerian angle γ and three translational parameters). The direct four-dimensional search within the unit cell produced a clear solution. The electron-density map based on this solution agrees well with the known structure, and the phase error calculated from the map was 61° within 20 Å resolution. It is anticipated that the low-resolution envelope can be used as a starting model for phase extension by the maximum-entropy and density-modification method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...