    Heat and mass transfer 13 (1980), S. 287-292 
    ISSN: 1432-1181
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Description / Table of Contents: Zusammenfassung Zur Messung schnell veränderlicher Fluidtemperaturen mit Hilfe von Berührungsthermometern sind im allgemeinen hohe Anströmgeschwindigkeiten der Fühler notwendig, um gute Wärmeübergangsverhältnisse sicherzustellen. Dadurch erhält der Recovery-Faktor dieser Fühler besondere Bedeutung. Haupteinflußparameter sind hier die Reynolds- und die Machzahl. Es wird der Recovery-Faktor eines Mantelthermoelementes von 0,5 mm Durchmesser in Wasserdampfströmung in Abhängigkeit von der Anströmmachzahl und der mit dem Manteldurchmesser gebildeten Reynoldszahl auf experimentellem Weg ermittelt. Untersucht werden die Bereiche 0,4 ⩽ M ⩽ 0,8 und 3000 ⩽ Re ⩽9000. Bei niedrigen Machzahlen und hohen Reynoldszahlen sind die Recovery-Werte klein. Sie steigen bis zu einer Grenz-Machzahl mit wachsender Anströmgeschwindigkeit und bei sinkender Reynoldszahl. Oberhalb dieser Grenze besteht keine Abhängigkeit von der Machzahl. Das Recovery-Verbalten des Fühlers wird entscheidend durch die Ablösezone bestimmt, die an der Fühlerspitze auftritt.
    Notes: Abstract Generally, high flow speeds are required to assure adequate heat transfer conditions in determining rapidly changing fluid temperatures by means of contact thermometers. Consequently, the recovery factor of these temperature gages is of predominant importance with Reynolds- and flow Mach numbers as main influence parameters. In the present study, the recovery factor of an enclosed thermocouple of 0,5 mm diameter is determined in steam as a function of free stream Mach number and Reynolds number based on the tip diameter. The Mach number range 0,4 ⩽ M ⩽ 0,8 and Reynolds numbers 3000 ⩽ Re ⩽ 9000 were considered respectively. It was found that the recovery factor is relatively small with low Mach numbers and high Reynolds numbers. Increasing the Mach number and lowering the Reynolds number yields higher recovery factors. After reaching a limiting value, no effect of the flow speed is observed and the recovery factor remains constant with increasing Mach number. Of major influence is the separation zone at the tip of the thermocouple.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...