ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 60 (1998), S. 97-104 
    ISSN: 0006-3592
    Keywords: fixed-bed bioreactor ; pressure drop ; biofilm growth monitoring ; Biofor ; friction factor ; Reynolds number ; wastewater treatment ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The possibility of following the biomass growth by pressure drop measurement was investigated in an aerated cocurrent upflow fixed-bed bioreactor continuously fed with wastewater containing industrial organic pollutants. The experiments were carried out in a biological filtration oxygenated reactor (Biofor) pilot plant packed with expanded clay balls (Biolite) of 2.7-mm diameter, which served as biomass carriers. The column was equipped for on-line pressure drop measurements. Correlation between pressure drop measurements and Reynolds numbers of air and water were determined in experiments carried out without biomass. Under operating conditions with biomass, it was demonstrated that column clogging and the operating time between washing cycles can be predicted depending on the volumetric organic load for a given total organic carbon inlet concentration. The biological activity of the fixed biomass was estimated from the oxygen consumption rate per unit time and carrier area. The oxygen consumption rate measurements demonstrated that the biological activity depends on the inlet substrate concentration, and that the Biofor column was most efficient between 75 and 100 g m-3 of total organic carbon inlet concentration. In the course of the wastewater treatment, using pressure drop measurements, the equivalent diameter of the Biolite particles, the reduced column macroporosity, and the biofilm thickness were calculated. An expression correlating biofilm density and biofilm thickness, as determined from the pressure drop measurements, was proposed. Good agreement was found between the fixed biomass in the reactor, determined as volatile suspended solids, and the biologically active biomass, estimated by respirometry. © 1998 John Wiley & Sons, Inc. Biotechnol Bioeng 60: 97-104, 1998.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...