ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 58 (1998), S. 416-427 
    ISSN: 0006-3592
    Keywords: protein separation ; isolation and purification ; aqueous two-phase extraction ; hydrogels ; gels ; polymer solution thermodynamics ; partition coefficients ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Use of the thermodynamic principles of aqueous two-phase extraction (ATPE) to drive protein into a crosslinked gel is developed as a protein isolation and separation technique, and as a protein loading technique for drug delivery applications. A PEG/dextran gel system was chosen as a model system because PEG/dextran systems are widely used in aqueous two-phase extraction and dextran gels (Sephadex®) are common chromatographic media.The effects of polymer concentrations and molecular weights, salts, and pH on the partitioning of ovalbumin matched ATPE heuristics and data trends. Gel partition coefficients (Cgel/Csolution) increased with increasing PEG molecular weight and concentration and decreasing dextran concentration (increased gel swelling). The addition of PEG to the buffer solution yielded partition coefficients more than an order of magnitude greater than those obtained in systems with buffer alone, or added salt. A combined salt/PEG system yielded an additional order of magnitude increase. For example, when ovalbumin solution (2.3 mg/mL) was equilibrated with Sephadex® G-50 at pH 6.75, the partition coefficients were 0.13 in buffer, 0.11 in buffer with 0.22M KI, 2.3 in 12 wt% PEG-10,000 and 32.0 in 12 wt% PEG-10,000 with 0.22M KI. The effect of anions and cations as well as ionic strength and pH on the partitioning of ovalbumin also matched ATPE heuristics.Using the heuristics established above, partition coefficients as high as 80 for bovine serum albumin and protein recoveries over 90% were achieved. In addition, the wide range of partition coefficients that were obtained for different proteins suggests the potential of the technique for separating proteins. Also, ovalbumin sorption capacities in dextran were as high as 450 mg/g dry polymer, and the sorption isotherms were linear over a broad protein concentration range. © 1998 John Wiley & Sons, Inc. Biotechnol Bioeng 58:416-427, 1998.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...