ISSN:
0930-7516
Keywords:
Chemistry
;
Industrial Chemistry
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Chemistry and Pharmacology
,
Process Engineering, Biotechnology, Nutrition Technology
Notes:
The energy consumption of ammonia plants based on steam reforming of naphtha or natural gas can be reduced by shifting the reforming load from the primary to the secondary reformer. It is shown that lowering of the primary reformer operating temperature 20 °C results in 2% increase of unconverted methane content in the outlet stream. The increased methane content can be processed in the secondary reformer if the process air inlet temperature is increased to 400 °C. The lower operating temperature reduces the energy consumption of the primary reformer by about 6% (and the overall consumption by about 2%) and also prolongs the service life of reformer tubes.
Additional Material:
7 Ill.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1002/ceat.270120151