ISSN:
0935-6304
Keywords:
Capillary electrochromatography
;
packed columns
;
fritless columns
;
stationary phases
;
Chemistry
;
Analytical Chemistry and Spectroscopy
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Chemistry and Pharmacology
Notes:
---Fritless packed silica gel columns were prepared using sol-gel technology. A part of a 75 μm i.d. fused silica capillary was filled with a mixture of tetramethoxysilane and poly(ethylene glycol). After gelling at 40°C and heating at 300°C, the resultant silica gel was derivatized with dimethyloctadecylchlorosilane. A scanning electron micrograph of a cross-section of the capillary column showed that the gel took the form of a spherical particle aggregate and adhered to the column inner wall. The column performance was evaluated for electrochromatography using acetonitrile-50 mM HEPES buffer (pH 6.6) (60/40 or 40/60, v/v) as the mobile phase. An electroosmotic flow of 1.0 mm/s was generated with (60/40, v/v) acetonitrile/HEPES buffer at a field strength of 546 V/cm. Using a sol-gel-derived packed column at an electroosmotic flow of 0.5 mm/s, efficiencies of up to 1.1×105 plates/m were obtained for retained solutes.
Additional Material:
4 Ill.
Type of Medium:
Electronic Resource