ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Series available for loan
    Series available for loan
    Hanover, NH : U.S. Army Cold Regions Research and Engineering Laboratory
    Associated volumes
    Call number: ZSP-201-78/26
    In: CRREL Report, 78-26
    Description / Table of Contents: Ice fog suppression experiments on the Fort Wainwright Power Plant cooling pond were conducted during the winters of 1974-76. Baseline information studies occupied a sizable portion of the available ice fog weather in 1974-75. Then hexadecanol was added to the pond and dramatically improved visibility by reducing fog generated from water vapor released by the pond at -14 C. Although this temperature was not low enough to create ice fog, the cold vapor fog created was equally as devastating to visibility in the vicinity of the pond. During the winter of 1975-76, suppression tests were continued using films of hexadecanol, mixes of hexadecanol and octadecanol, and ethylene glycol monobutyl ether (EGME). Suppression effectiveness at colder temperatures was stuided and limits to the techniques were probed. A reinforcing grid was constructed that prevented breakup of the film by wind and water currents. Lifetime tests indicated that EGME degrades much more slowly than either hexadecanol or the hexadecanol-octadecanol mix. The films were found to be very effective fog reducers at warmer temperatures but still allowed 20% to 40% of normal evaporation to occur. The vapor thus produced was sufficient to create some ice fog at lower temperatures, but this ice fog occurred less frequently and was more quickly dispersed than the thick fog that was present before application of the films.
    Type of Medium: Series available for loan
    Pages: iv, 27 Seiten , Illustrationen
    Series Statement: CRREL Report 78-26
    Language: English
    Note: CONTENTS Abstract Preface Introduction Ice fog from cooling ponds Evaporation Relative humidity and cold air Ice fog suppression Air movement Plastic films Rafts Injection wells Cooling towers Chemical films Reinforced film experiments Meteorological data collection Floating reinforcement grid Application of the hexadecanol film Hexadecanol, octadecanol mixes Ethylene glycol monobutyl ether Laboratory tests of suppression effectiveness Conclusions Literature cited Appendix A. Design for an automatic thin chemical film applicationsystem Appendix B. Meteorological data
    Location: AWI Archive
    Branch Library: AWI Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗