ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Artikel  (6)
  • fire tests  (4)
  • quantitative analysis  (2)
  • 1980-1984  (6)
  • 1925-1929
  • Architektur, Bauingenieurwesen, Vermessung  (6)
Sammlung
  • Artikel  (6)
Verlag/Herausgeber
Erscheinungszeitraum
Jahr
Thema
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Fire technology 20 (1984), S. 48-58 
    ISSN: 1572-8099
    Schlagwort(e): Residential sprinkler systems ; fire control ; survivability criteria ; obscuration ; carbon monoxide ; fire tests
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Architektur, Bauingenieurwesen, Vermessung
    Notizen: Abstract A series of National Fire Protection Association full-scale tests involving sprinkler installations was conducted in a two-story residence in Los Angeles, CA, and in a mobile home in Charlotte, NC. Previous laboratory tests, including full-scale room fire tests, had indicated that a prototype “quick-response” sprinkler was effective in controlling residential home fires. More full-scale fire tests under less controlled and more operational conditions were considered necessary to confirm or deny this conclusion. Part I of this three-part series (November 1983) explained the objectives of the tests and the test procedures that were to be followed. This second part describes the criteria used to evaluate the effectiveness of sprinkler systems using the “quick response” sprinkler in the series of seventy-six tests and the results of those tests. Part III will cover that phase of the test program that focused on a comparison of sprinkler and smoke detector activation times in the mobile home test structure.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1572-8099
    Schlagwort(e): Hazard analysis ; risk assessment ; risk management ; explosion ; fire ; risk avoidance ; hazard indices ; HAZOP ; quantitative analysis
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Architektur, Bauingenieurwesen, Vermessung
    Notizen: Abstract The report briefly describes the consecutive steps in the identification, assessment and comparison of hazards and associated risk. These techniques can be helpful in setting the priorities for the decision on measures to reduce risk. When quantifying risk for the comparison of alternative cases, the use of a consistent data base is stressed. It is pointed out that the risk assessment techniques described in the report, although potentially valuable tools for improving overall safety performance, have shortcomings particularly in dealing with human factors. A glossary is appended to define terms as they are used in this report and a list of recommended further reading is included. Part II will appear inFire Technology, November 1984.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    Fire technology 20 (1984), S. 41-46 
    ISSN: 1572-8099
    Schlagwort(e): Mobile home ; sprinklers ; smoke detector ; fire tests
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Architektur, Bauingenieurwesen, Vermessung
    Notizen: Abstract A series of full-scale fire tests utilizing prototype “quick-response” sprinklers was conducted in a two-story residence in Los Angeles, CA, and a mobile home in Charlotte, NC. A prime objective of the program was to test the performance of alternative sprinkler designs to “control” the development of fire in single-family dwellings and mobile homes. Part of the mobile home test series focused on a study of the comparative activation times of sprinklers and smoke detectors installed in the same areas under a variety of test conditions. The results of that phase of the test program are given here.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 1572-8099
    Schlagwort(e): Hazard analysis ; risk assessment ; risk management ; explosion ; fire ; risk avoidance ; hazard indices ; HAZOP ; quantitative analysis
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Architektur, Bauingenieurwesen, Vermessung
    Notizen: Abstract The report briefly describes the consecutive steps in the identification, assessment and comparison of hazards and associated risk. These techniques can be helpful in setting the priorities for the decision on measures to reduce risk. When quantifying risk for the comparison of alternative cases, the use of a consistent data base is stressed. It is pointed out that the risk assessment techniques described in the report, although potentially valuable tools for improving overall safety performance, have short-comings particularly in dealing with human factors. A glossary is appended to define terms as they are used in this report and a list of recommended further reading is included. Part I appeared inFire Technology, August 1984.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    ISSN: 0308-0501
    Schlagwort(e): Combustion of plastics ; combustion properties ; fire tests ; heat of combustion ; ignitability ; oxygen consumption ; rate of heat release ; Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Architektur, Bauingenieurwesen, Vermessung , Maschinenbau
    Notizen: A new bench-scale rate of heat release calorimeter utilizing the oxygen consumption principle has been developed for use in fire testing and research. Specimens may be of uniform or composite construction and may be tested in a horizontal, face-up orientation, or, for those which do not melt, in a vertical orientation. An external irradiance of zero to over 100 kW m-2 may be imposed by means of a temperature-controlled radiant heater. The rate of heat release is determined by measuring combustion product gas flow and oxygen depletion, while the mass loss is also recorded simultaneously. The instrument has been designed to be capable of higher accuracy than existing instruments and yet to be simple to operate and moderate in construction cost. The instrument is thermed a ‘cone calorimeter’ because of the geometric arrangement of the electric heater.
    Zusätzliches Material: 11 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Fire and Materials 8 (1984), S. 206-216 
    ISSN: 0308-0501
    Schlagwort(e): building materials ; fire tests ; heat release rate ; oxygen consumption ; spectral energy distribution ; weight measurement ; Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Architektur, Bauingenieurwesen, Vermessung , Maschinenbau
    Notizen: Equipment has been developed for measuring the rate of heat release from building materials in an open test arrangement. The method is based on an oxygen consumption technique. A vertical sample is placed under an open hood in which the combustion gases and a certain amount of air are collected. The decrease in oxygen concentration and the mass flow of the gases are measured in the exhaust duct. The rate of heat release is then calculated. The equipment has been calibrated with good agreement between input and measured effects. The total response time for the system is 10s. The method has been used for testing building materials at radiation intensities up to 5W Cm-2. It is able to distinguish between different board materials, and the repeatability is good, The paper describes the equipment, including the weighing of a burning sample and the selection of test condition. Smoke and gas analysis can be added when desirable. Some test results with building materials are also presented.
    Zusätzliches Material: 16 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...