ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Column liquid chromatography  (1,216)
  • Springer  (1,216)
  • Blackwell Publishing Ltd
  • Cell Press
Collection
Keywords
Publisher
Years
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Reversed-phase ; Codeine phosphate drug substance ; Opium alkaloids
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A rapid procedure for the evaluation of codeine phosphate drug substance derived from poppy straw or opium concentrate is described. The gradient HPLC procedure employs a pH 2.5 phosphate buffer, methanol and acetonitrile mobile phase at 40°C and a μBondapak C-18 column. Eight opium alkaloids, including the four major alkaloids, are separated from each other. The paper describes details of the assay procedure and presents data documenting the linearity, specificity, precision, and sensitivity of the method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; External variance determinations ; Column and system compatibility ; Microbore and fast LC
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The demand for faster, more economic and convenient high-efficiency LC analyses has led to the development of microbore and fast columns. However, to utilize their benefits, the low column dispersions produced by these new technologies necessitate low external variances in the total system. This paper describes the determination of the external variance of microbore, fast and conventional LC systems by a column method. Compatibility with the relevant column technologies is evaluated by a method involving the comparison of the external and column dispersions. Direct comparison of chromatograms of an 8-component mixture, on a set of columns of various diameters and lengths, shows the relative speed, economy and sensitivity obtainable in practice. The problem of reduced sample loadability is considered and the practical solution of peak compression illustrated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Retention prediction system ; UV multichannel detector ; Polycyclic aromatic hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The retention prediction system assisted by a micro-computer coupled with an UV multichannel detector has been investigated in the separation of polycyclic aromatic hydrocarbons. The method offered very precise identification of components in NBS-SRM-1647 sample without any standard reference substances. It has been proven that the system makes very precise, non-pollutive and convenient environmental analysis possible.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 20 (1985), S. 313-322 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Tetracyclines antibiotics ; Quantitation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The use of high-performance liquid chromatography (HPLC) for the identification and determination of tetracycline antibiotics is reviewed. HPLC chromatograms provide fast identification by retention time, tR, and precise quantitation by measurement of peak height or peak area. For separation of tetracycline compounds, most HPLC methods use reversed-phase C18 or C8 columns and UV detection. The HPLC solvent system should have a pH of about 6 to prevent steric changes in the tetracycline molecule. For accurate quantitation it is necessary to avoid tailing and this is accomplished by adding a zwitter ion to the solvent system. Methanol and acetonitrile are frequently used as organic modifiers in these solvent systems. In a single analysis, HPLC methods can be used to separate as many as nine or ten commercially used tetracycline compounds and to determine four to five tetracyclines in commercial tetracycline preparations or in biological fluids.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Resolution of optical isomers ; Chiral column ; Pyrethroids ; Fenvalerate
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The separation of the optical isomers of fenvalerate [cyano(3-phenoxyphenyl)methyl 2-(4-chlorophenyl)-3-methylbutyrate] has been carried out by high-performance liquid chromatography (HPLC) on a chiral column with (R)-N-3,5-dinitrobenzoyl-phenyl-glycine (DNBPG) covalently bonded on aminopropyl silica and eluted with mixtures of methanol, 2-propanol, and hexane. The system was applied to the analysis of Pydrin®, an emulsifiable concentrate formulation of fenvalerate, and to the residue analysis of fenvalerate in milk samples. For the analysis of Pydrin® the only requirement was the proper dilution of Pydrin® with hexane. For the analysis of residues in milk, fenvalerate was extracted with hexane after precipitating the milk proteins with acetonitrile and removing the precipitate by filtration; the hexane extract was concentrated to small volume and filtered before being analyzed by HPLC.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 20 (1985), S. 487-494 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Size-exclusion chromatography ; Controlled-porosity glasses ; Boron-enriched glass surface ; Adsorptive properties
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Controlled-porosity glasses (CPG) are sieves for macromoleculars, very widely applied in chromatographic columns for the separation of polymers and biopolymers by means of size-exclusion chromatography (SEC) and affinity chromatography. This paper deals with the influence of the thermal treatment of CPG on the elution of polymers in SEC columns. The problem is examined for a few mobile phases and for glasses having different porosities. Additionally, the SEC results obtained are compared with the adsorption properties of the glases investigated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Electrochemical detection ; Cysteinyldopamine ; Tyrosinase ; Autoxidation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary 5-S-Cysteinyldopamine, a new metabolite of dopamine, was determined in urine by high-performance liquid chromatography with electrochemical detection. The catechol was detected in 14 of 21 melanoma patients and 7 of 21 normal subjects; the highest values were 657 μg/day for melanoma patients and 44 μg/day for normal subjects. These results suggest that the cysteine conjugate may arise from autoxidation of dopamine but tyrosinase may also participate in the oxidation.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 21 (1986), S. 136-142 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Chemical reaction detector ; Carbamate insecticides ; Quantitation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary For the determination of trace amounts of carbamate insecticides in vegetables the combination of liquid chromatography with post column chemical derivatization (chemical reaction detector) is used. In a two step reaction detector the carbamates are firstly saponified in 0.01 M sodium hydroxide at 80°C with a reaction time of 30sec. To this mixture OPA reagent is added to detect the methylamine generated in the saponification. Optimization strategies for this reaction are demonstrated. At a temperature of 80 °C a reaction time of 80 sec is sufficient for quantitative transformation of the methylamine. The peak dispersion can be reduced and hence the detection limit improved by decreasing the diameter of the tubes and by diminishing dilution through the addition of reagent. A 1∶24 ratio of reagent to column (reactor) effluent is possible with cyclone-type mixers. The quantitation of carbamates in different vegetables is demonstrated. The detection limit is 20ppb at a signal to noise ratio of 10∶1.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 21 (1986), S. 205-213 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Chiral phases ; Optimization of separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The preparation and properties of chiral bonded phases with amino acid groups are described. These phases were used in non-polar eluents and in aqueous systems in the presence of Cu2+ ions in the ligand-exchange mode. The optimization of chiral resolution is demonstrated for both cases. With non-polar eluents similarity between bonded groups and solutes is required. The elution could be accelerated by non-protonic moderators. Ligand-exchange separation is influenced by the copper content of the eluent and the stationary phase, the organic moderator concentration, the pH and ionic strength of the buffer and by the temperature. Structural requirements of both the bonded groups and of the solutes for chiral separation are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Reversed-phase capacity factors ; Cavity term ; Molar volumes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Reversed-phase liquid chromatographic capacity factors are well correlated by an equation of the form: $$logk' = (logk')_0 + mV/100 + s\pi ^* + b\beta + a\alpha $$ wheremV/100 measures the cavity term and π*, β, and α are the solvatochromic parameters that measure solute dipolarity/polarizability, hydrogen bond acceptor basicity, and hydrogen bond donor acidity respectively. Liquid molar volume (molecular weight divided by liquid density at 20°C) $$\bar V$$ , and computer-calculated intrinsic (van der Waals) molecular volume, $$\underset{\raise0.3em\hbox{$\smash{\scriptscriptstyle-}$}}{V} _I $$ , are compared as measures of the cavity term in a number of correlations. $$\underset{\raise0.3em\hbox{$\smash{\scriptscriptstyle-}$}}{V} _I $$ leads to more precise correlations as well as to a “cleaner” dissection of the multiple solute/solvent interactions. The opposing exoergic effect of solvent donor/solute acceptor hydrogen bonding, and endoergic cavity term are the main factors influencing HPLC capacity factors.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...