ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 04. Solid Earth::04.06. Seismology::04.06.06. Surveys, measurements, and monitoring  (30)
  • INGV  (30)
  • American Chemical Society
  • American Institute of Physics (AIP)
  • Molecular Diversity Preservation International
Collection
Years
  • 1
    Publication Date: 2021-05-12
    Description: In questo lavoro si presentano i risultati di uno studio sulle caratteristiche del rumore sismico in prossimità del rilevatore di onde gravitazionali VIRGO (Cascina, Pisa), con particolare riferimento alle vibrazioni associate all’azione di un vicino parco eolico. La valutazione delle componenti spettrali del rumore verosimilmente indotte dagli aerogeneratori è stata effettuata mediante (i) Misure dirette alla base di una turbina, (ii) Correlazione fra le ampiezze spettrali del rumore e la velocità del vento; (iii) Determinazione delle proprietà direzionali da misure multicanale, (iv) Misura dell’attenuazione del segnale con la distanza dal parco eolico. Il disturbo provocato dagli aerogeneratori è particolarmente energetico alla frequenza di 1.7 Hz e, in particolari condizioni, è stato osservato fino a distanze di 11 km dal Parco Eolico. Il decadimento spaziale delle ampiezze ha un andamento complesso, che può essere interpretato in termini di una combinazione fra onde superficiali e onde di volume rifratte ad un’interfaccia profonda (~800 m) fra i sedimenti plio-pleistocenici ed i calcari Miocenici. La risposta locale nei dintorni dell’interferometro è stata investigata utilizzando la tecnica dei rapporti spettrali H/V. Si sono così evidenziate due bande di amplificazione imputabili ad effetti di risonanza legati alla geologia a scala locale: il primo intorno alla frequenza di 0.35 Hz, il secondo fra 0.7 e 2.0 Hz. Entrambi i picchi risultano essere essenzialmente omogenei in tutta l’area di studio, a conferma della sostanziale uniformità della struttura geologica.
    Description: Published
    Description: 1-30
    Description: 1.1. TTC - Monitoraggio sismico del territorio nazionale
    Description: N/A or not JCR
    Description: open
    Keywords: Seismic Noise ; Array Seismology ; Gravity Waves ; 04. Solid Earth::04.06. Seismology::04.06.06. Surveys, measurements, and monitoring ; 04. Solid Earth::04.06. Seismology::04.06.09. Waves and wave analysis
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2021-03-01
    Description: Questo lavoro presenta una utility per il GIS MapInfo™ sviluppata per l'archiviazione ed elaborazione dei dati macrosismici dalla fase di georeferenziazione fino al plottaggio finale su mappa. L'identificazione della località associata con un'osservazione macrosismica è un'operazione che talvolta può causare errori ed in seguito problemi nell'analisi ed interpretazione dei dati. La routine MacroMap fornisce uno strumento che in modo semplice e veloce aiuti nell'identificazione della corretta località a cui attribuire l'informazione macrosismica durante lo studio di un terremoto. L'utility è strutturata per utilizzare il formato della directory geografica DIR04 e le procedure adottate nella compilazione del DataBase Macrosismico Italiano DBMI04. MacroMap è stata sperimentata "sul campo" durante alcune indagini macrosismiche e tiene conto dell'esperienza e dei suggerimenti degli operatori del Gruppo QUEST (QUick Earthquake Survey Team). I campi di utilizzo di MacroMap vanno dalla realizzazione speditiva di mappe e tabelle per la produzione di report macrosismici per la Protezione Civile, alla revisione di terremoti storici, grazie all'avanzato sistema di query disponibile per la selezione dei toponimi del database geografico.
    Description: Published
    Description: 1-21
    Description: 5.1. TTC - Banche dati e metodi macrosismici
    Description: N/A or not JCR
    Description: open
    Keywords: Osservazioni macrosismiche ; 04. Solid Earth::04.06. Seismology::04.06.05. Historical seismology ; 04. Solid Earth::04.06. Seismology::04.06.06. Surveys, measurements, and monitoring ; 05. General::05.02. Data dissemination::05.02.02. Seismological data
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2013-04-18
    Description: Twenty-five lava fountains occurred on Mt. Etna from January 2011 to April 2012. In summer 2012 volcanic activity resumed in a milder form within the Bocca Nuova crater, before it came to an essential halt in August 2012. All these unrests offer rich material for testing automatic procedures of data processing and alert systems, running 24/7, in the context of volcano surveillance. We focus on the seismic background radiation – volcanic tremor – which plays a key role in the monitoring of Mt. Etna. Since 2006 a multistation alert system has been established in the INGV operative centre of Catania exploiting STA/LTA ratios. Besides, also the spectral characteristics of the signal, which change correspondingly to the type of volcanic activity, can be exploited for warning purposes. Here we apply Self Organizing Maps and Fuzzy Clustering which offer an efficient way to visualize signal characteristics and its development with time. All these techniques allow to identify early stages of eruptive events, and automatically flag a critical status before this becomes evident in conventional monitoring techniques. Changes of tremor characteristics are related to the position of the source of the signal. The location of the sources exploits the distribution of the amplitudes across the seismic network. The locations were extremely useful for warning, throughout both the flank eruption in 2008 as well as the 2011 lava fountains, during which a clear migration of tremor sources towards the eruptive centres could be noticed in advance. The location of the sources completes the picture of an imminent volcanic unrest, and corroborates early warnings flagged by the changes of signal characteristics. Real time data processing requires computational efficiency, robustness of the methods and stability of data acquisition. The amplitude based multi-station approach is not sensitive to the failure of single stations and therefore offers a good stability. The single station approach, exploiting unsupervised classification techniques, limits logistic efforts, as only one or few key stations are necessary. Both strategies have proven to be insensitive to disturbances (undesired transients like earthquakes, noise, short gaps in the continuous data flow). False alarms were not encountered so far. Stable data acquisition and processing come with a properly designed data storage solution. The reliability of data storage and its access is a critical issue. A cluster architecture has been realized for failover protection, including a Storage Area Network system, which allow easy data access following predefined user policies. We present concepts of the software architectures deployed at INGV Osservatorio Etneo in order to implement this tremor-based multi approach system. We envisage the integration of seismic data and those originating from other scientific fields (e. g., volcano imagery, geochemistry, deformation, gravity, magneto-telluric). This will facilitate cross-checking of evidences encountered from the single data streams, in particular allow their immediate verification with respect to ground truth.
    Description: Published
    Description: Nicolosi (Catania, Italy)
    Description: 1.4. TTC - Sorveglianza sismologica delle aree vulcaniche attive
    Description: 5.6. TTC - Attività di Sala Operativa
    Description: open
    Keywords: Etna, Volcanic tremor ; Volcano monitoring, Pattern recognition ; Self Organizing Map, Fuzzy clustering ; Data acquisition ; 04. Solid Earth::04.06. Seismology::04.06.06. Surveys, measurements, and monitoring ; 04. Solid Earth::04.06. Seismology::04.06.08. Volcano seismology ; 04. Solid Earth::04.08. Volcanology::04.08.06. Volcano monitoring ; 05. General::05.01. Computational geophysics::05.01.01. Data processing ; 05. General::05.01. Computational geophysics::05.01.04. Statistical analysis
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: Oral presentation
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2017-04-04
    Description: The modern digital seismic stations are provided with 24 bit A/D converters, high capacity recording systems and broad-band seismometers. Nevertheless, few tens year old seismic stations can be still able to give an useful contribution to seismic monitoring. Some out-of-date seismic stations, such as the Lennartz PCM 5800, are characterized by the data acquisition in trigger mode on magnetic tape, allowing a continuous recording time of about 90 minutes. We have checked the possibility to substitute the Uher tape recorder of the Lennartz PCM 5800 stations with modern digital recorder, in order to give a new life to these stations. Several type of digital recorders have been tried. According to the results of our trials, the Hi-MiniDisc (Hi-MD) recorder is resulted the most useful one. This apparatus records on 1GB magneto-optical disks with a continuous recording time up to about 8 hours. This time allows to record about 500 trigger windows of about 50-60 seconds on one disk, about 5 time the old magnetic tape. According with these results, the Lennartz PCM 5800 digital seismic stations can be useful during seismic experiments or as a support of the Permanent Seismic Networks at local and regional scale.
    Description: Published
    Description: 1-17
    Description: 1.4. TTC - Sorveglianza sismologica delle aree vulcaniche attive
    Description: N/A or not JCR
    Description: open
    Keywords: seismic station ; temporary network ; 04. Solid Earth::04.06. Seismology::04.06.06. Surveys, measurements, and monitoring
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2017-04-04
    Description: Questa nota presenta una sintesi delle attività svolte durante il rilievomacrosismico del terremoto avvenuto tra le province di Parma e Reggio Emilia il 23 dicembre 2008. La scossa di Ml 5.2 è stata localizzata a sud di Parma ed è stata avvertita in tutta l’Italia settentrionale e in gran parte della Liguria e della Toscana. Il presente rapporto illustra lemodalità di intervento del teamQUEST, relative al rilievo degli effetti e alla valutazione in intensità MCS in particolare per le località della zona epicentrale. L’ampia documentazione fotografica illustra alcuni dettagli delle tipologie di danneggiamento rilevate e consente di comprendere meglio le valutazioni dell’intensità macrosismica. This paper presents an overview of the activities performed during the macroseismic field survey of the earthquake that occurred in the Parma and Reggio Emilia region on December 23, 2008. The mainshock (Ml=5.2), was located south of the city of Parma and was resolutely felt through Northern Italy. The report here presented shows the procedures carried out by QUEST (Quick Earthquake Survey Team), concerning the survey. QUEST has been engaged in gathering the damage information and in assessing the macroseismic intensity, in particular about the epicentral area. A copious photo collection shows details of the observed damage nature and allows to better illustrate the intensity
    Description: Published
    Description: 1-41
    Description: 5.1. TTC - Banche dati e metodi macrosismici
    Description: N/A or not JCR
    Description: open
    Keywords: rilievo macrosismico ; 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous ; 04. Solid Earth::04.06. Seismology::04.06.06. Surveys, measurements, and monitoring
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2017-04-04
    Description: Seismic networks are worldwide diffuse to monitor both volcanic and tectonic seismogenetic areas. Some differences, such the basement on which the seismometer is located and the environmental conditions, characterize the installation of seismic stations in volcanic and tectonic areas. Nevertheless, some basic principles are common. To obtain good quality seismic data is very important to realize a high grade installation of all the instruments equipping a seismic station. Several procedure must be taken into account to optimize the instrument setting up. Electronic noise may be minimize using proper connecting line and adequate grounding. Effective lightning protections are essential to save instruments from both surges and strikes. Good seismometer ground coupling improves the signal quality and the signal-to-noise ratio. These procedures have been carried out at the Osservatorio Vesuviano to improve the existing seismic network as well as the installation of the new stations. As a result of this action an improvement of both the signal-to-noise ratio and the network reliability has been obtained.
    Description: Published
    Description: 1-20
    Description: 1.4. TTC - Sorveglianza sismologica delle aree vulcaniche attive
    Description: open
    Keywords: seismic network ; siting ; 04. Solid Earth::04.06. Seismology::04.06.06. Surveys, measurements, and monitoring
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2017-04-04
    Description: In questo lavoro viene descritto il complesso sistema di acquisizione dati della RSM [vedi D’Alema et al., 2011 - in questo volume], costituita da 58 stazioni collegate in tempo reale e 13 stazioni dial-up. I dati delle stazioni in tempo reale sono acquisiti con il programma Seiscomp31; la detezione degli eventi sismici viene eseguita con il programma Earthworm ed infine l’analisi e l’interpretazione degli eventi viene effettuata attraverso il programma SacPicker di Daniele Spallarossa [vedi Spallarossa, 2011 - in questo volume]. La parte di rete dial-up è basata sul sistema Lennartz Mars882 ed è configurata in modo autonomo dalla rete in tempo reale. I dati delle due reti vengono successivamente uniti in un unico dataset ai fini di una interpretazione interattiva congiunta.
    Description: Published
    Description: 124-127
    Description: 1.1. TTC - Monitoraggio sismico del territorio nazionale
    Description: N/A or not JCR
    Description: open
    Keywords: rete sismica ; ancona ; acquisizione dati ; 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous ; 04. Solid Earth::04.06. Seismology::04.06.06. Surveys, measurements, and monitoring ; 04. Solid Earth::04.06. Seismology::04.06.10. Instruments and techniques
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2017-04-04
    Description: Da alcuni anni l’INGV e la Regione Marche collaborano nell’azione di monitoraggio sismico del territorio regionale. Nella sede di Ancona del CNT sono acquisiti in tempo reale i segnali sismici di circa 80 stazioni dell’Italia centro-orientale. Si è reso pertanto necessario sviluppare applicativi utili al controllo degli apparati che compongono il sistema di monitoraggio. In particolare, vengono controllati: 1) lo stato di funzionamento delle trasmissioni radio ed ethernet; 2) lo stato dell’alimentazione delle stazioni e il numero di satelliti ricevuti dagli apparati GPS; 3) la quantità di segnale sismico archiviato e i gaps del segnale continuo; 4) i livelli di rumore di fondo e la qualità del segnale sismico.
    Description: Published
    Description: 104-107
    Description: 1.1. TTC - Monitoraggio sismico del territorio nazionale
    Description: N/A or not JCR
    Description: open
    Keywords: rete sismica ; ancona ; centro acquisizione ; telecomunicazioni ; qualità segnali ; 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous ; 04. Solid Earth::04.06. Seismology::04.06.06. Surveys, measurements, and monitoring ; 04. Solid Earth::04.06. Seismology::04.06.10. Instruments and techniques
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2017-04-04
    Description: A Pilot Project for CO2 injection and storage was proposed for a gas storage area located at Cortemaggiore (Piacenza), in northern Italy. This project is conducted both to verify the injection techniques and to analyze the potentiality of CO2 as a cushion gas. Starting from 2004, a series of analysis has been conducted to verify suitability and feasibility of this operation. The injection phase will be preceded by a passive seismic monitoring in order to measure the background seismicity of the area. Seismic monitoring will be carried out during the 3 years of the injection phase and will continue also for a control period of 2 years, following the working phase. The Milano - Pavia Department of the Istituto Nazionale di Geofisica e Vulcanologia is in charge of the surface seismic monitoring. To study the background seismicity a microseismic network composed by 7 seismic stations has been realized. On February 2010, a first test phase has been conducted for 3 sites. The network was completed with 4 more stations on May 2010. All stations are composed by a 24-bit digital recorder (Lennartz M24/NET) with GPS time signal. The study area is characterized by a very high anthropic and industrial noise. In order to improve the quality of the seismic signals, 4 stations have been installed in a 100 m deep borehole. The seismic sensors (Lennartz LE-3D/BH for the borehole and LE-3Dlite MKI for the installation at the surface) have similar technical characteristics with 1 Hz free period, cutoff frequency at 80 Hz and dynamic range of 136 dB. In this first stage we analyzed the microseismic noise level and evaluated the detection capability of the network. Using the RMS measurements the borehole stations indicate a reduction on the noise by a factor of 2.5. A more detailed analysis, performed using the density function distribution of the power spectra, evidences a 10 dB gain for the borehole stations in the frequency band 1 - 10 Hz. Noise measurements have been used also to determine the minimum magnitude for the events detection. Using a point source model to simulate seismic events, we verified the expected detection levels by comparing the estimates obtained with the simulation and the local events recorded by the seismic network.
    Description: Published
    Description: 12
    Description: 1.1. TTC - Monitoraggio sismico del territorio nazionale
    Description: N/A or not JCR
    Description: open
    Keywords: seismic monitoring ; gas storage ; micro-seismicity ; 04. Solid Earth::04.02. Exploration geophysics::04.02.99. General or miscellaneous ; 04. Solid Earth::04.02. Exploration geophysics::04.02.06. Seismic methods ; 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous ; 04. Solid Earth::04.06. Seismology::04.06.06. Surveys, measurements, and monitoring ; 04. Solid Earth::04.06. Seismology::04.06.10. Instruments and techniques
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2017-04-04
    Description: Nell’ambito del progetto FIRB-Airplane [“Piattaforma di ricerca multidisciplinare su terremoti e vulcani”, fondi MIUR 2007-2011 responsabili: Cocco, Amato e Stucchi1] dalla seconda metà del 2009 è stata installata una rete densa di stazioni sismiche nell’area dell’Alta Val Tiberina (AVT, Figura 1), i cui dati in continuo vengono trasmessi alla sede di Ancona del CNT attraverso una dorsale Wi-Fi HYPERLAN [Monachesi e Cattaneo, 2010]. La rete è stata progettata cercando di rispettare alcuni criteri, tra cui: controllo continuo della funzionalità delle singole stazioni, flessibilità nella scelta dei siti, riduzione del rischio di fulminazioni, possibilità di abbinare stazioni sismiche e stazioni geodetiche. A tal fine sono stati adottati strumenti a basso consumo per quel che riguarda acquisitori e sistemi di trasmissione, accompagnati dall’utilizzo di sistemi di alimentazione autonomi e sistemi di telecontrollo
    Description: Published
    Description: 91-93
    Description: 1.1. TTC - Monitoraggio sismico del territorio nazionale
    Description: N/A or not JCR
    Description: open
    Keywords: rete sismica ; alta val tiberina ; sistemi alimentazione ; 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous ; 04. Solid Earth::04.06. Seismology::04.06.06. Surveys, measurements, and monitoring ; 04. Solid Earth::04.06. Seismology::04.06.10. Instruments and techniques
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...