ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (180)
  • Chemistry  (148)
  • Polymer and Materials Science  (148)
  • Engineering General  (32)
  • Analytical Chemistry and Spectroscopy
  • Biochemistry and Biotechnology
  • Inorganic Chemistry
  • Physics
  • Wiley-Blackwell  (180)
  • ANU Press
  • Boston, MA : Springer
  • World Scientific
  • 1965-1969  (180)
  • Technology  (180)
Collection
  • Articles  (180)
Keywords
  • Chemistry  (148)
  • Polymer and Materials Science  (148)
  • Engineering General  (32)
  • Analytical Chemistry and Spectroscopy
  • Biochemistry and Biotechnology
  • +
Publisher
  • Wiley-Blackwell  (180)
  • ANU Press
  • Boston, MA : Springer
  • World Scientific
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969) 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 3-28 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: Finite element methods can be formulated from the variational principles in solid mechanics by relaxing the continuity requirements along the interelement boundaries. The combination of different variational principles and different boundary continuity conditions yields numerous types of approximate methods. This paper reviews and reinterprets the existing finite element methods and indicates other alternative schemes. Plate bending problems are used to compare the relative merits of the various methods.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 1-2 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 47-66 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: Three methods for finding natural frequencies and modes of complex structures composed of beam elements are described and compared. The analysis is extended to include hysteretic damping for the determination of response and transmissibility without a modal analysis. Experimental comparison is given for the response of a simple engineering structure.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 101-122 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The derivation of the stiffness matrix for a refined, fully compatible triangular plate bending finite element is presented. The Kirchhoff plate bending theory is assumed. Six parameters or degrees of freedom are introduced at each of the three corner nodes resulting in an 18 degree of freedom element. This refined element is found to give better results for displacements and particularly for internal moments than any plate bending element, regardless of shape, previously reported in the literature.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 67-73 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: Finite difference treatment of two-dimensional problems in elastostatics is usually based on the differential equations for the displacement vector or the Airy stress function, depending on whether boundary conditions are on displacement or stress. In either case, determination of stresses requires numerical differentiation and therefore use of a rather fine grid. Moreover, neither method is suited to the treatment of mixed boundary conditions. The alternative method developed in this paper uses the first derivatives of the displacement components at the grid points as basic variables and hence does not require numerical differentiation in the evaluation of stresses. Appropriate finite difference equations are established, and their use is discussed in connection with a specific example with known explicit solution.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 29-45 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The theory, function generator routine and testing procedures are given for a six-node 18 degree of freedom triangular element. At corner nodes the variables are the displacement and the two slopes. At midside nodes the variables are the displacement, the slope normal to the side, and the rate of change of this along the side - i.e., the rate of torsion. Of two options, one divides the triangle into three and takes different quartic displacements in the three regions, and the other uses displacement functions with singularities at the vertices. According to a test which compares the energies of the two formulations by eigenvalues, the second is the better if the integration is accurate. The same test, together with others based on finite differences and on nodal values, etc. checks the correctness of the routine decisively.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 123-133 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The large deflection problem of a rectangular plate is analysed by using the finite element method and employing the iteration technique. In the present study, the stiffness matrix of a rectangular plate element for bending proposed by Greene is employed, and results of numerical examples duly justifies applicability of the present method.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 75-100 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The paper presents first a general formulation of the elasto-plastic matrix for evaluating stress increments from those of stresses for any yield surface with an associated flow rule. A new ‘initial stress’ computational process is proposed which is shown (1) to yield more rapid convergence than alternative approaches (2) to permit large load increments without violating the yield criteria and thus simply to establish lower bound solutions. Several solutions showing stress distribution, strain development and growth of plastic enclaves are given both for the von Mises and for Coulomb (Drucker) type yield surfaces. Load reversal and thermoplastic behaviour are dealt with.
    Additional Material: 18 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969) 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 151-162 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The direct Finite Element Analysis which was successfully employed in the solution of dynamic flexural traveling wave problems is extended herein to provide the transient behaviour of finite beams and plates in which shear deformation and rotatory inertia are considered. The particle and angular velocities are exponentially damped so that the static solutions for these problems are obtained with the same analysis which provided the dynamic and transient cases. Three special cases are chosen as examples. In the first, a sinusoidally varying shear force is applied at the tip of a cantilever beam. The resonant characteristics of this beam for both the undamped and damped cases are studied. In the second, a step shear loading is applied to a cantilever beam and its damped dynamic history is studied. Finally, a circular plate whose outer edge is simply supported is impacted at its inner edge by a step moment and its damped transient behaviour is determined. The idea of the methods is potentially applicable to dynamic problems in general.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 135-149 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The assumed stress distribution approach is used to derive the stiffness matrix of a plate-bending element of general polygonal shape having any number of nodes. The effect of assuming various numbers of unknown coefficients in the stress distributions is examined and the convergence properties of the resulting elements compared with others derived form assumed displacements.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 169-175 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: A numerical method for obtaining the Green's functions for Laplace's, Poisson's, and the transient heat diffusion equations is presented. The Green's functions thus obtained are then employed to rapidly obtain numerical solutions of the above equations by matrix multiplication, with subsequent considerable savings in machine time.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 177-180 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The solution of the large numbers of non-linear algebraic equations occurring in analyses of non-linear structural systems using finite differences or finite elements is time consuming even for the fastest computers. This paper presents a method of solution based on a Taylor's expansion technique which is an aid in the solution of such systems of equations.Examples presented show that in the finite element analysis of moderately non-linear structural systems the technique provides sufficiently accurate solutions. For more non-linear systems the technique provides excellent starting values for the Newton-Raphson method.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 163-167 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: Deformation functions which, in addition to satisfying the continuity conditions at nodes. Also satisfy. Approximately, the governing differential equation within the element allow system eigenvalues to be found more accurately, with a given number of elements, than is possible with previously published deformation functions. This is illustrated for the case of beams.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 201-203 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 205-221 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: This paper presents a general theory of finite elements. The concept of finite elements is cast in a general topological framework valid for spaces of finite dimension. It is shown that the idea of finite element models can be developed in higher-dimensional spaces, independent of specific co-ordinate systems, for any type of continuous abstract function defined on the space. Generalizations of the familiar Lagrange and Hermite interpolation functions are presented as well as a general statement of the notion of generalized variables and conjugate fields. It is also shown that admissible finite elements can be developed for non-Euclidean spaces of finite dimension. Topological properties of finite element models are examined in Part I of the paper. Part II is devoted to certain applications.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 224-224 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969) 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 225-245 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: A method is presented based on matrix algebra for the dynamic analysis of a mixed rotating and non-rotating vibration system. Such systems occur in practice when turbo-alternator sets are mounted on flexible steel foundations.The mathematical model considered consists of a rotating non-uniform, bi-symmetric shaft connected via three or more flexible-film bearings to a flexible structure throughout which mass is distributed. The shaft, which is assumed to rotate at constant speed, is heavy, flexible and carries several rigid axi-symmetric discs. Viscous damping is assumed to act in all parts of the system and gravitational effects are ignored.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 181-200 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: Surface displacements at the end of a semi-infinite, circular cylinder due to an axisymmetric ring of forces on the end are examined. The solution which has been found may then be used to find surface displacements for general axisymmetric loadings by convolution. The solution, in tabular form, is given as corrections to the counter-part half-space solution.The method of solution involves a three step superposition process. First, the displacement due to a ring of forces on a half-space is found by using the Boussinesq solution. Then, the excess tractions on the half-space, over that of the cylinder, are removed. This is done in two parts. The problem of an infinite cylinder with linearly varying pressure and shear over a short length of the lateral surface is solved by using Fourier integrals. This is used for the removal of the pressure and shear on the lateral surface of the cylinder by convolution. Next, the stresses at the mid-section of the infinite cylinder are removed. This is done by finding a set of boundary conditions for the end which yields zero tractions on the lateral surface. Then a series of these boundary conditions is used to approximate the tractions which must be removed.With the solution thus obtained, two sample problems are shown: 1. an elastic cylinder in contact with a half-space; 2. a rigid punch in contact with an elastic cylinder.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 247-259 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: In Part I of the this paper, topological properties of finite element models of functions defined on spaces of finite dimension were examined. In this part, a number of applications of the general theory are presented. These include the generation of finite element models in the time domain and certain problems in wave propagation, kinetic theory of gases, non-linear partial differential equations, non-linear continuum mechanics, and fluid dynamics.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 275-277 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 261-274 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: A presentation is made of a rectangular plate bending element, the use of which corresponds to the finite difference method. The element stiffness matrix is arrived at by approximation of the strain energy of the element by suitably selected finite difference expressions which contain not only values in respect of the deflection, but also values of its first derivatives. On the basis of the connection found between the two methods, some changes are suggested in the finite difference method, which involve a more realistic way of considering the detailed distribution of the loading. The effect of these modifications is illustrated in two applications.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 279-299 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: When calculating complex interconnected systems (electrical, power, water supply, gas systems, etc.) by digital computer, a number of common problems arise, connected both with the mathematically correct formulation of the problem under investigation, and with the algorithms of the solution, the programming of which makes it possible to reduce the computing time, the store capacity and the volume of input data required. The present article is devoted to the solution of these problems. The procedure is illustrated by formulating and manipulating the equations relating to complex interconnected mine ventilation networks.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969) 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 301-310 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: Solution of plane elastic problems by piecewise linear approximation is outlined. This method is based upon Galerkin error distribution technique, which leads to simultaneous algebraic equations identical to those associated with the Finite Element Method. In addition, this method permits definition of the discretization error, which can be computed once the displacement components are known. Properties of the interpolation functions are discussed, and a sequence of internally compatible plane elastic elements is defined.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 311-331 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: A review is given of some mathematical programming methods suitable for optimization of structures needing matrix methods for analysis. An application is presented for elastic flat grillages made of straight orthogonal beams normally loaded. Empirical relationships are used to relate beam section properties so that each beam element has only one design variable. Optimization results are obtained by methods of stress-ratio, linear programming-cutting plane and usable-feasible gradient directions. A comparison of the efficiency of these methods is given for the grillage designs which are shown to have non-convex stress constraints and numerous relative optima. Instances are given of non-fully stressed global optima and fully stressed designs which are not local optima for cases with only stress constraints. Discussions include locating the global optima for grillage designs and extensions of the methods presented to other structural design problems.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 333-349 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The paper presents a method for reducing the size of a vibration analysis by generating an inertia matrix referred to a limited set of ‘master’ vibrational freedoms. In designing a computer program to perform this mass condensation process, the emphasis has been on providing a two way interface between structural analysis and vibration analysis programs. The transformation from the full set of degrees of freedom to the master set makes extensive vibration calculations economically feasible giving solutions in terms of the amplitudes of the master freedoms. However, by reversing the transformation after completion of a vibration analysis, it is possible to restore the full set of freedoms, allowing automatic plotting of mode shapes in full detail, and re-entry to the structural analysis program for the purpose of computing dynamic stresses.A worked example is given. This is a realistic machine tool structure rather than the simple plates or beams which are usually used for illustration purposes. Natural frequencies and mode shapes, calculated with various degrees of condensation, are compared with those obtained by using all possible freedoms. A comparison is also made with an intuitive selection of ‘lumped masses’.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 351-378 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: The application of non-linear programming methods for the optimum design of statically indeterminate structures is discussed, with special emphasis on the design of elastic grillages loaded laterally and in plane. Some features of SUMT (sequential unconstrained minimization technique) are demonstrated by means of numerous examples of varying complexity. The Variable Metric method of search is discussed and compared to Powell's Direct Method. It is shown that non-convex sets of design variables are often encountered in structural problems of the grillage type. SUMT may still be used, but the choice of starting value and initial response factor decisively influences the chance of finding the global optimum.It is demonstrated that a fully stressed design may not necessarily correspond to the minimum weight design. Optimum design of grillages which are simultaneously subjected to lateral and in-plane loads may be performed efficiently by means of non-linear programming.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 379-394 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: A completely numerical method for steady state linear viscoelastic stress analysis is presented by means of the finite element approach. Numerical representations of the measured viscoelastic constitutive relations are used. This method is developed to obtain steady state solutions to mixed boundary value problems in which the character of the boundary conditions at a point changes with time. Such problems cannot be handled by direct application of the correspondence theorem. A numerical example of viscoelastic sheet rolling is presented along with an experimental verification of the solution by photo-viscoelastic observations.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 1 (1969), S. 395-395 
    ISSN: 0029-5981
    Keywords: Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 1-2 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 11-16 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Methyl α-cyanoacrylate, when implanted subcutaneously in rats and dogs, has been shown to lead to an increase in thiocyanate output in the urine, presumably through the formation of cyanide anions which are subsequently converted to thiocyanate. It is postulated that this reaction may be one of the reactions contributing to tissue necrosis when methyl α-cyanoacrylate is used as a tissue adhesive.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 3-9 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: In an effort to obtain tissue adhesive monomers which would wet and spread on tissue substrates and be rapidly biodegradable, the branched esters of alkyl α-cyanoacrylates, as well as a 95-5 wt.-% mixture of n-heptyl and methyl α-cyanoacrylate, were studied. The data indicate that alkyl α-cyanoacrylates having branched alkoxy groups appear to be promising in this regard.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 27-31 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A theory for the behavior of anodes as stimulus electrodes, particularly as pacemaker electrodes, is presented. Expressions are obtained for the minimum duration and energy of the stimulus. These expressions are applied to that for the dissolution of the anode and transport of the resulting ions in the tissue in order to obtain an estimate of the extent of penetration. Comparison with experimental data indicates good agreement.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: New dialysis membranes, prepared from linear block copolymers, have shown unique separation properties which appear to be based on definite solute-membrane interaction. The synthesis and characterization of block copolyetherurethanes based on poly (oxyethylene glycol) is described.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 33-54 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Currently available materials for mechanical heart systems are surveyed, particularly with respect to long-term implantation, from the viewpoints of availability and workability, mechanical and biological durability, and compatibility with blood and tissue. Some materials have one or more desirable physical properties, but none offers perfect blood and tissue compatibility. Medical grade Silastic, considered best for blood handling parts, has produced promising results in auxiliary ventricle patency experiments. The insufficient tensile strength of Silastic should be increased, and it may be possible to accomplish this while maintaining the present resilience, elongation, and inertness. No long-term data on thrombus formation are available, but clot-retarding quality is essential and may perhaps be obtained by incorporating heparin. Developments in polymer chemistry may also lead to other surfaces with the requisite mechanical properties with blood.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Seven surgical adhesives were prepared; n-butyl, 2-ethylhexyl, and isopropyl cyanoacrylate monomers and several combinations of ethyl cyanoacrylate and a plasticizer (either di-2-ethylhexyl phthalate or tricresyl phosphate). These were implanted as a thin film over the entire circumference of the adventitia of 48 canine carotid arteries. Vicissitude of cyanoacrylate polymers in vivo and tissue reaction to the polymers were traced for 6 months and investigated histologically. All adhesives tested in this study were insoluble in vivo and more resistant to biodegradation than methyl cyanoacrylate polymer. Tissue reaction against n-butyl, 2-ethylhexyl, or isopropyl cyanoacrylate was essentially the same as against ethyl cyanoacrylate in quality and was not less in degree than ethyl cyanoacrylate in spite of having longer side chains than ethyl radical.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Evidence is presented for the view that intravascular thrombosis proceeds via an electrochemical mechanism. It is strongly substantiated by some recent work on electrical wire thrombosis. These experiments show that thrombosis occurs on noble metal electrodes at potentials more positive than 0.3 v (NHE) but tends not to occur on electrodes more negative than this interfacial potential. Further, the same factors which prevent intravascular thrombosis are shown to prevent thrombosis on electrodes maintained at all potentials up to + 1.0v. Thus occurrence or prevention of thrombosis appears related to electrical and electrochemical properties of both blood and blood vessel wall. Methods for the determination of these properties are described and experimental results briefly presented. The studies have proved useful in establishing criteria for the selection of metal and plastic vascular substitutes. A combination of several electrochemical and biophysical criteria have been discovered which aid in the selection of nonthrombogenic vascular substitutes. Unfortunately not all metals which satisfy anti-thrombotic electrochemical criteria are suitable. Many, including magnesium, have cellular and proteolytic destructive characteristics. Certain metals and electrically treated Teflon tubes do not suffer from this defect and have proven useful in preliminary testing.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A major part of current effort in improving artificial hemodialysis techniques concerns the development of improved membrane structures. Although blood compatibility of membranes is a part of the Battelle program, this discussion is confined to membrane composition, structure, and transport. On the basis of a need for improved hemodialysis techniques, membranes for use in the artificial kidney were prepared and evaluated for urea, creatinine, and uric acid permeability. Water-soluble polymers were crosslinked to form insoluble, but swellable, membranes. Faster metabolic waste transfer than with the conventional cellulosic membranes was obtained with diisocyanate-crosslinked poly (vinyl pyrrolidone) and poly (vinyl pyrrolidone)-dextran membranes and with membranes obtained by crosslinking poly (vinyl alcohol) with polyfunctional aldehydes. Membranes prepared from emulsions of vinyl pyrrolidone-ethyl acrylate and vinyl pyrrolidone-styrene copolymers had exceptionally high urea and creatinine dialysis rates, but were deficient in uric acid transfer. This shortcoming was corrected by incorporating solutes such as sucrose into the membranes followed by leaching. Another important approach concerned the development of a relatively high-strength membrane based on an impermeable nylon resin. Permeability of these membranes which have dialysis characteristics superior to those currently used was obtained through the addition of DMSO and one of several other additives to the coating solution.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The tissue reaction to metallic and nonmetallic implants in the back muscles of New Zealand White Rabbits is presented. These reactions are graded and correlated with the trace metal contained around such implanes. Correlations are drawn as to the acceptability of various materials for the manufacture of surgical implants.
    Additional Material: 18 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 103-112 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The pressure losses in the currently available prostheses are too high. We believe an excellent way to focus designers' attention upon this fact is to rank the various designs according to their hydraulic efficiency. The proposal of this paper is for pressure drop vs. velocity data (pulsatile flow) to be taken similar to that of Figure 2, so that a pressure loss coefficient, Kv, based upon the valve lumen area can be found for each valve design; further, that this Kv be used to compare and rank the various valve designs. The fact that Kv is a dynamic loss coefficient guides designers toward its improvement, for this compares the prosthesis problem to many “solved” problems (propeller blade profiles, hydrofoil profiles, etc.) which are similar hydraulically. The confusion of the surgeon when confronted with conflicting claims regarding various prostheses would be largely eliminated by acceptance of Kv as a figure of hydraulic merit by those concerned with this aspect of biomedical engineering.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 171-174 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The problems with the experimental and clinical assessment of arterial prosthetic materals vary from species-transfer of data to vested interests once an implantale device has been perfected for human trail. In spite of all the problems which arise, there has been a steady increase in our knowledge of the basic healing pattern of implanted arterial prostheses and the elaboration of specific paths for improvement of prosthetic design. Further development will be linked closely to the active participation of the biomedical researcher in areas of biophysical and bioengineering investigations.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 113-134 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Semicrystalline polymers used as restorative prostheses in the cardiovascular system require more detailed consideration of flexural fatiguing with simple physical characterization and mechanical measurements as one basic means for developing test standards and specification levels for biomedical research materials. Such initial means are considered with polytetrafluoroethylene as a reference polymer nominally inert chemically used to illustrate one approach to assessing morphological and structural changes with a flex tester. Density measurements and void content have been carried out to provide one means of assessment whereby the corresponding crystallinity and permeation can be considered for more detailed correlation to cytological interactions as the polymers are used as replacement components in the cardiovascular system. Progressive flexural cycling up to 106 cycles at a 3 cps rate indicate significant decreases in crystallinity simultaneously with increasing void content. As an accelerated test, the implications for extrapolation to 25-year fatiguing in normal physiological cycling rate are conjectured to provide a starting point for more realistic, cyclic ex vivo screening of biomaterials.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 175-175 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 175-175 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 176-176 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The clotting problem inside the artificial heart device is one of the major obstacles standing in the way of a successful long-term implantation of the artificial heart. To date, there have been two artificial heart devices used clinically. One is the auxiliary ventricle and the other is the left heart bypass pump. The former is for permanent implantation and the other is implanted only temporarily. Several experimental results which had contributed to the successful implantation of the auxiliary ventricle are described, especially from the standpoint of avoiding the clotting inside the device. Basic experiments with the left heart bypass pump are also described. The valves are the foremost problem and the next is the junction of the two materials. It is ideal to have a smooth, seamless surface made entirely of one material. It is also necessary to have a flow pattern analysis inside the artificial heart device as well as a clotting pattern analysis. Since the pump oxygenator and heparinization are involved in the procedure, the clotting problems in the total heart experiment are usually less than in the left heart bypass experiments. Our most urgent requirement is the development of new antithrombogenic material. However, even with our present material a large part of the clotting could be avoided if the heart is carefully constructed.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 179-196 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Warp-knitted velour fabrics of Dacron, nylon, polypropylene, and Rayon have been backed with Silastic to form a laminate. Prior to heat curing, the composite can be molded into many shapes and has been successfully used to line the luminal side of blood pumps and vascular grafts. Prosthetic heart valves are being covered with velour in an attempt to promote a more compatible surface. Velour suture rings are being evaluated as a more efficient anchor for prosthetic heart valves. Silastic tubes with velour bonded to the outer wall have been used to inhibit infection and sinus tract formation where percutaneous lead wires and conduits are necessary. As a flat sheet, the Silastic-velour laminate has been used experimentally as an artificial skin, but the most noteworthy experimental results have been obtained in rats using a double layer of nylon velour, separated by an impermeable layer of poly(vinyl fluoride). Future application will include attempts to anchor artificial limbs via a velour interface and made functional by tendinous attachment.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Inhibition of cultured mammalian cell growth was used to examine the biological activity of triethyl citrate, a common plasticizer for poly(vinyl chloride). Cell populations were determined by a sample extraction procedure and measurement of nucleic acid content (total purines and pyrimidines) by its absorbance at 268 mm̈. Triethyl citrate demonstrated strikingly different dose-effect characteristics from its theoretical hydrolysis products (ethanol and citric acid). The inhibitory effects of sodium citrate were reversed by calcium chloride while the action of triethyl citrate underwent little or no change under similar conditions. Triethyl citrate did not appear to produce resistant cell strains in culture but did seem to be degraded with time. Inhibitory action of triethyl citrate was shown to be independent of inoculum size within the ranges utilized in the study. The procedures described appear to have a number of advantages for the biological or toxicological evaluation of ingredients which might be added to a plastic formulation or to contaminates which might enter the plastic during manufacture of the item or device.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A series of studies were performed using S35-labeled heparin to determine the amount and the permanancy of heparin grafted onto nonthrombogenic surfaces. The calculated thicknesses of the heparin layers (based on geometrical areas) ranged from 100 to 1500 A. It was shown that the surface having a 100-A layer of attached heparin was nonthrombogenic. The stability of the heparin attached to polypropylene, silicone rubber, hydrin rubber, and graphite-benzalkonium-heparin (GBH) surfaces in distilled water, isotonic saline, and human plasma was measured. The results showed that after exposure to water and saline, the first three surfaces retained most of the attached heparin (〉90%) in contrast to the GBH surface which retained only 31%. After contact with human plasma for 3 hr at 37°C, polypropylene retained 32% and GBH surfaces 19% of the heparin which was initially present. In another series of experiments, the adsorption of P32-labeled proteins onto unheparinized, quaternary ammonium, and heparinized surfaces was measured. The results indicated that the amounts of albumin, Hageman factor, thrombin, and γ-globulin adsorbed onto heparinized surfaces were equal to or greater than the amounts adsorbed onto unheparinized surfaces. The implications of this in terms of the nonthrombogenicity of the heparinized surfaces are discussed.
    Additional Material: 7 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 213-238 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: 1. With the help of ionotropic gels it is possible to duplicate native structures consisting of two materials, one of them the matrix. 2. Counter-ions combined with the ionic groups on the ordered polyelectrolytes can be exchanged. With certain counter-ions an insoluble, crystalline precipitate is formed immediately after the ion-exchange process as an ordered reaction product, i.e., nucleation. 3. Ionotropic gels were crosslinked through the secondary hydroxyl groups (uronic acid residuals) in such a way that the rate of ion exchange was only slightly lower, that no great shrinkage resulted, and that the pores remained free of extraneous polymers. 4. The microscopic structure of ionotropic gels can be divided into (a) a part with secondary structure with micellar particles and hollow pores and (b) a part with tertiary structure with lamellae and isopores. 5. On crystallization in shrunken gels the crystals enter into the tertiary structure - both intracapillary as well as interlamellar - due to spatial reasons. 6. Through control of the shrinkage of the gels, one can regulate the way in which the ordered crystals enter into the two structures. 7. One can change the size of the crystallites by variation of the degree of crosslinking. The higher the degree of crosslinking, the smaller the crystallite. 8. By treatment with waves of ions one can increase the solid content of the gel to values from 50 to 70%. One obtains gels with a mechanical strength like that of bones, teeth, shells, or pearls. The phenomenon of intramicellar crystallization is reversible. Monovalent counter-ions, as well as H-ions, dissolve and extract the included secondary substance. One then obtains the original crosslinked gel. 10. The gel has always to be formed first. Without the ordered base structure (matrix) one obtains unordered crystallites such as occur in the chalklike fields of the pearl shells.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 253-261 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Porous laminates prepared by incorporating a volatile solvent into an epoxy resin system used to impregnate a fabric filler satisfactorily alleviated the problems caused by perspiration in upper extremity prostheses, but did not have sufficient strength for use in artificial legs. A new technique is described which results in a 100% increase in both porosity and strength of porous epoxy laminates. The method consists of impregnation of the fabric with resin and solvent and evaporation of the solvent prior to laying up the laminate. The improvement in properties is ascribed to better control and homogeneity of impregnation.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 275-284 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A design theory is developed for a compact artificial kidney utilizing microcapsules containing urease, ion exchange resin, and adsorbents for uric acid and creatinine. It is shown that the critical factor is the permeability property of the microcapsule wall and that an artificial kidney 10 cm in length and 2 cm in diameter is feasible.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 285-297 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Samples of (Ag + Hg) amalgam and of dental amalgam have been prepared and stored at temperatures of 23, 37.5, and 60°C for various lengths of time up to 10 years. X-ray diffraction and optical microscopy have been employed to determine the approximate increase in the β(Ag—Hg) phase as a result of the γ → β transition in the Ag—Hg system. Data are presented to show that the transition occurs in both systems but much less rapidly in dental amalgam. Increases in storage temperature increase the rate of the transition in both systems.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Strains were determined in a typical mandibular partial denture metal framework of the free-end saddle type. The overall strain patterns were determined using a brittle lacquer coating technique and loads were applied vertically to positions on the saddles. The results from the coating study indicated the area of high strain were just anterior and posterior to the finishing lines. Strain gages were attached to positions anterior and posterior to the finishing lines and the strain was measured at these positions when the saddles were loaded either at a posterior or anterior position at intervals of 2 lb up to 20 lb. When a static load of 20 lb was applied to the posterior of the left saddle a strain of 750 μ in./in. was obtained, which for the alloy used was equivalent to a stress of 22,200 lb/in.2. The amount of strain observed was a function of the length of the saddle, the bulk of the framework, the relation of the site of the gage to the position of loading, the presence of an indirect retainer, and the position of the fulcrum for the loading conditions used.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 299-299 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 301-312 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The present paper describes a new technique for preparing the surface of polyethylene and polypropylene plastics for the adsorption of heparin. The procedure consists of exposing the plastic surface to a solution of cationic surfactants at a temperature close to the softening temperature of the plastic. The mechanism of adsorption of the anticoagulant of the surfaces is discussed.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 325-336 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: In 14 canines the ureter was substituted with a new type of ureteral gel-fabric prosthesis. The prosthesis is a tube of knitted fabric of polyester fiber case in a layer of hydrophilous glycol methacrylate gel. Anastomoses were carried out by inserting the prosthesis ends into the ureter lumen and by suturing the stump of the ureter to a special fixing ring on the prosthesis. Preliminary results of short-term obsevations (4 months) are quite promising. The prosthesis is non-irritating and conducts the urine satisfactorily.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 313-323 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The biologic properties of the sponge-like polymers of ethylene glycol methacrylate gels and their host compatibility have been verified in subcutaneous and intraperitoneal application in rats. All three sample types tested, with different porosities, have been tolerated very well with the receptor and have caused no pathologic reaction. Subcutaneous implants are directly integrated in teh organism, cellular immigration taking place with vascularization of the surface layer of the implantate to a depth of some 500 μ during the second week after implantation, causing the sponge to become an integral component of the surrounding tissues. More substantial differences in the reaction to the presence of implantates of different porosity ahve not been observed. These properties directly predetermine the sponge-like polymers for wider application in plastic and reconstructive surgery. In addition, there is the possibility of utilizing them as an auxiliary surgical material, e.g., for drying and cleaning the operative field, or as operation towels. Good results have been achieved also in mechanically stopping bleeding from parenchymatose organs by application of the sponge foil.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 337-354 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Features controlling the initiation of matrix calcification have been investigated in a model system. Two major influences which dominate nucleation are the matrix integrity and the location of certain chemical binding sites. It has been shown that chemical chelating groups can, and do, promote calcification under simulated physiological conditions. Organically bound phosphate does not appear to promote nucleation, suggesting that it is chelation of calcium or other cations which is the initial step in tissue calcification. In the sequence of compounds investigated for nucleation catalysis, those possessing at least three chelating groups and a stereopsecific configuration were effective. The mineral phase forming first in association with the organic matrix is a soft non-apatitic calcium phosphate of Ca/P ratio approximately 1.5. This is the same phase that forms in the absence of organic matrices at physiological pH and is probably the precursor to hydroxyapatite in biological calcification. It is suggested that nucleation catalysts exist both within and outside the collagen fibrillar framework. A possible location of the internal site has been proposed, based on the availability of a capillary channel and chelating ligands, and this postulate is supported by electron microscopic evidence which shows that bone crystals lie within the fibrils, occupying space which terminates in the polar 640 A staining area.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 369-369 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Knowledge of the characteristics of the blood-intima interface is important because it leads to information concerning (a) the normal antithrombotic mechanism (b) nature of interreactions between blood and intima (c) testing and selection of vascular wall substitutes which are antithrombotic and inhibit clotting. A technique for obtaining the electrical interfacial characteristics of blood vessel walls is by measuring streaming potentials. Experiments described in the present work are extensions of original in vivo streaming potential measurements. In vitro streaming potentials were measured across fresh canine aortae and carotid arteries using Krebs saline serum substitute, logarithmically varying both internal and external electrolyte concentrations. Positive streaming potentials were measured indicating that the blood vessel wall is negatively charged. Streaming potentials increased linearly with increasing flow rate, decreased with increasing internal electrolyte concentration, decreased with increasing external electrolyte concentration, and reversed, becoming positive, with aging of exteriorized artery. Thus the electrical characteristics of the blood vessel wall are dependent on an ionic balance between the blood vessel wall, flowing blood stream, and external environment. The information demonstrates the importance of electrochemical and physicochemical phenomena in the structure and function of the vascular interface and helps explain in vivo conditions conducive to or inhibitory of intravascular thrombosis.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 387-394 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The authors followed the tissue response of a new plastic tube composed of neutral hydrophilic gel, after implantation in the subcutis of rats. They further studied tissue reaction when gel rods were connected by polymerization in situ. After implantation, the gel tubes developed a fine encapsulation but no inflammatory response. The gel rods were connected “end to end” by means of a drop of the polymerizing mixture. The healing proceeded in the same manner with the exception that minute granules of macrocellular elements were formed in the ligament surrounding the polymerization mixture remnats. According to these results, the neutral hydrophilic gel has proved to be a suitable material for implantation.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 371-386 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A new intraoral adhesive bandage composed of gelatin, sodium carboxymethylcellulose, and polyisobutylene backed by a layer of polyethylene film was used by 148 investigators in 1468 patients. The bandage adhered well to the fixed mucosa of the palate, gingiva, and teeth. It adhered less satisfactorily to the loose mucosa of the cheek and floor of the mouth. It did not adhere very well to the tongue. The duration of adhesion of the bandage was at least 5 hr in approximately 87% of all treated cases, and it remained in place for 9-51 hr for more than 50% of all treated patients. Tolerance of the application was good or excellent in 75% of all cases. There was no irritation attributable to the bandage in any patient. The bandage provided an effective means of protecting the vital repair mechanism of a wound during the early hours after extraction. The results of these trials indicate that the new adhesive bandage is safe and that it provides effective cover and protection of wounds and lesions of the mucous surface up to 24 hr.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 395-404 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Sutured, stapled, and methyl- or thickened n-pentyl-2-cyanoacrylate-adhered end-to-end arterial anastomoses were compared in two series of 10 dogs, employing the three 4-mm diameter terminal branches of the aorta for these comparisons. Patency rate, speed of construction, and gross and microscopic appearances were employed as criteria for evaluation. In a series of adult white rabbits the same criteria were applied to compare sutured and thickened n-pentyl-2-cyanoacrylateadhered end-to-end anastomoses of the 2-mm diameter abdominal aorta. Anastomoses adhered with methyl-2-cyanoacrylate were significantly more often thrombosed than any other variety; a marked inflammatory response followed application of this material. Thickened n-pentyl-2-cyanoacrylate adhesive was well tolerated, and the results obtained with this material were equivalent to those obtained by suturing or stapling in the dog, or by suturing in the rabbit.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 405-414 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Corrosion resistance is particularly important in medical treatments requiring implantation of metallic objects in the human body. Unfortunately, weight loss measurements and other conventional corrosion testing techniques are insufficiently sensitive and difficult to adapt to in vivo environments. The linear polarization technique can be used to remotely meaure the corrosion rates of metals implanted in tissue using needle probes. The principles of this technique are reviewed and the results of tests performed on steel, cobalt, and molybdenum implanted in experimental animals are discussed.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 415-425 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The presence of the β1 phase in dental amalgam after 60°C heating has been confirmed by x-ray diffraction, metallography, microhardness tests, and electron beam analysis. It appeared that the γ1 → β1 transformation began at preferred sites, believed to be possibly areas deficient in Hg, and grew outward from these sites. Even after heating for nearly a year, however, some γ1 still remained in the sample.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 427-432 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: In vivo and in vitro experiments described herein have demonstrated that the GBH coating is antithrombogenic when placed on PVC, as tested in the blood system of rabbits for periods up to 2 weeks. In vitro clotting times cannot be correlated with the in vivo thrombogenicity of the same implants. For example, dog and man have very similar in vitro clotting times, but very dissimilar in vivo prosthetic thrombosis problems. In vivo and in vitro tests are for the most part not comparable in that they do not measure the same things. However, both in vivo and in vitro tests proved the GBH-treated vinyl to be antithrombogenic. It may be concluded from the available data that a flexible plastic can be treated with GBH and become antithrombogenic for a practicable period of time.
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 1 (1967), S. 433-449 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Man-made polymeric materials are being utilized in a number of devices which will be implanted into animals and humans for various periods of time. The diversity of materials and the introduction of new materials into the medical and paramedical professions appear to be increasing at an accelerated rate each year. Even though great advancements have been made by the biomedical engineer and the surgeon in designing and implanting a prosthetic device in the body, less emphasis apparently has been given to the possible or potential hazardous aspects of the material. An implantable material may initiate a body response in two general ways: (1) release of an ingredient from the material to the biological environment and (2) alteration of the material by the biological environment, leading to degradation of the material with its various consequences. If serious future hazards are to be kept to a minimum, greater emphasis must be placed on well-designed toxicity studies of materials which, in turn, could lead to standardized materials for implants.
    Additional Material: 4 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 1-22 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Several metallic orthopedic implants which failed in service and for which the medical histories are known are comprehensively examined using metallographic techniques and electron microprobe analyses to determine the causes of failure. The results indicate that fatigue is a major cause of failure and that, in all probability, the fatigue is initiated by poor design or poor material.
    Additional Material: 20 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 43-49 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Tubing made of a polar plastic, polychlorotrifluoroethylene, was electrically polarized while heated. The zeta potential of tubes polarized negatively inside was consistently higher than that of unpolarized tubes. Tubes polarized positively had a much smaller and variable change in zeta potential. The change is apparently not related to the formation of electrets, but may be due to the orientation of pre-existing dipoles.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 23-42 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The effect of phenol and certain phenyl compounds on the different stages of the blood coagulation and fibrinolytic mechanism is investigated. Phenol has a complex action on blood coagulation. In an optimal concentration of 0.3% it produced a definite, though suboptimal platelet factor 3 activity, evolved factor XII, accelerated thrombin-fibrinogen interaction, retarded clot retraction, enhanced the action of streptokinase on plasminogen, and inhibited plasmin. In addition, in the absence of factor XIII and calcium, it increased the solubility of fibrin in urea. Phenyl acetaldehyde, benzyl benzoate, and styrene (phenyl ethylene) accelerated stypven clotting time and thrombin-fibrinogen reaction. Unpolymerized styrene and phenyl ethanol specifically inhibited the action of plasma thromboplastin, formed in a system lacking in factor VIII or IX. A study is also reported on the changes responsible for the stabilization with phenol of brain thromboplastic activity. The action is not purely bactericidal, but is dependent on the presence of brain tissue particles in suspension. The contribution of platelets to plasma thromboplastin formation is examined in the light of these investigations, showing the ability of phosphorus-free compounds to supply a platelet-like activity.
    Additional Material: 16 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 81-88 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Adult albino rabbits were implanted with disks of 316 and 304 stainless steel in the subperiosteum of the anterior calvarium and the left mandible and in the left paravertebral and thigh muscles. The corresponding opposite sites were sham operated. The histopathological slides revealed that there was variation in thickness of the membrane in sections of both the paravertebral and thigh muscles; one side showing greater reaction than the other, which corresponded with the appearance of the implants. Sections of the calvarium revealed minimal bone and soft tissue reaction, although the implants showed corrosion compatible with soft tissue sites. The mandibular sections revealed extensive bone tissue reactions with minimum masseter muscle reactions, but the appearance of the implants due to corrosion was different than those of all other sites. Moderate eosinophilic infiltration was observed in sections containing deposits of corrosion products.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 89-93 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An alternate correlation of blood coagulation time with surface properties of solids is proposed in that the work of adhesion is used rather than the surface free energy. The overall quality of the two correlations is about the same, but the new method does allow the important data point for glass to also be included. Possible useful future work of this type is discussed.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 51-79 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Bioelectric charge transfer at the blood-wall interface may be a crucial factor affecting thrombosis on implant materials. A program of studies was conducted to determine the electrokinetic and other physical properties of a wide spectrum of materials including organic polymers, metals, inorganics, heterogeneous compounds, and animal tissue. From these tests, materials were selected for in-vivo cannulation experiments. In this manner, a search was made to find a correlation between surface charge characteristics and thrombosis on cardiovascular implant materials. It was found that materials exhibiting a substantial positive charge were prone to rapid thrombosis. No clear correlation can be stated, as yet, regarding the thrombogenecity of highly charged negative surfaces or slightly charged surfaces. However, many heterogeneous materials have exhibited prolonged in-vivo patency. It appears necessary to isolate surface effects from volumetric effects to seek the role of bioelectric charge transfer in blood thrombus formation.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 121-130 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A segmented polyurethane elastomer, originally developed for elastic thread, is now being used for molded prostheses. Chemical, mechanical, and biological properties are described. Hydrolytic stability of this polymer is compared to that of a polyester urethan. Experience with the material used in components of an experimental heart-assist pump has shown excellent flex endurance, wear resistance, and intravascular acceptability.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 131-143 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: During the period covered by this investigation, toxicological studies were carried out in hamsters and rabbits. The results of injections, subcutaneously and in the buccal pouch of hamsters, indicated that the silicones used were nontoxic, non-absorbable, and well encapsulated by connective tissue elements with moderate tissue reaction. Further studies of various combinations of roomtemperature vulcanizing silastics indicated similar reactions when injected submucosally in the alveolar ridges and palate of rabbits. The injected materials remained in situ in the injected submucosal area and became well encapsulated by the proliferation of connective tissue and collagenous fibers. There was no evidence of macrophages or foreign body giant-cells in and around the proliferating connective tissue capsule. There were no macroscopic or microscopic signs of tumor formation. The encapsulated masses did not elicit bone resorption when localized adjacent to bone tissue.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 95-119 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The effects of variations in composition and processing on the open-circuit electrode potentials measured as a function of time of amalgams made from silver-tin, silver-tin-copper, silver-tin-zinc, and silver-tin-copper-zinc alloys have been determined at 37°C in distilled water, in saline solution, as well as in acetate and citrate solutions buffered to pH values of 3, 7, and 10. The electrochemical potentials of the alloys measured as a function of time in neutral acetate solutions show anodic polarization from an initial cathodic potential value of approximately 0.1 v with respect to the standard hydrogen electrode to a constant potential level depending upon alloy composition. In neutral acetate solution the potential-time curves of silver-tin amalgams with 7:5 mercury to alloy ratio show a rapid anodic polarization from an initial anodic potential value of 0.28 v to a minimum value of 0.05 v at approximately 1 hr followed by a potential reversal to a plateau value of 0.40 v. For 7:5 amalgams in neutral acetate solutions increases in both the trituration time and in the severity of processing deformation cause a small increase in initial potential, with a decrease in anodic polarization, while an increase in amalgam age lowers both the initial potential value and the longer-time potential plateau. Increasing the mercury content of the amalgam to a 2:1 ratio decreases the rate of potential reversal from the minimum, whereas decreasing the ratio to 4:5 decreases the amount of depolarization from the minimum value. The effects of copper and zinc additions to silver-tin alloys are mixed. In neutral acetate solution the 7:5 ratio amalgams from silver-tin-copper alloys show anodic polarization from the same initial value as the silver-tin amalgams, followed by a region of decreased polarization. Both silver-tin-zinc and silver-tin-copper-zinc alloys exhibit a much higher initial anodic potential (0.78 v), and following the achievement of the potential plateau have a slow anodic polarization to the long-time potential value shown by silver-tin amalgam. Three commercial alloy amalgams were studied in neutral acetate solution. The two amalgams containing zinc have a potential behavior similar to that of the experimental zinc-containing amalgam; the non-zinc amalgam shows a rapid anodic polarization from an initial anodic potential value of 0.24 v, a minimum at 1 hr, and a reversal to the long-time potential values of 0.40 v shown by the zinc-containing amalgam.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 157-163 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Three monomers, β-14C-tagged methyl, n butyl, and n-heptyl α-cyanoacrylate, have been applied to intact skin and split-thickness skin-graft donor sites on rats. The data indicate that the urinary 14C activity is in the order: methyl 〉 n-butyl or n heptyl. Also, the urinary activity, when the monomers are applied to the split thickness skin graft donor sites, is approximately threefold greater than when the monomers are applied to intact skin. The conclusion is that the application of cyanoacrylate monomer to the skin is not only topical in nature, but may involve the internal milieu as well.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 145-155 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Polyelectrolyte complexes are ionic hydrogels formed by the coreaction of two oppositely charged, strongly ionized polyelectrolytes. While insoluble in simple solvents and infusible, these polymers can be fabricated into membranes, fibers, and other shaped articles by casting from ternary solvents. Homogeneous membranes are optically clear, amorphous structures in which the equilibrium gel water content can be controllably varied from ca. 30-90%. The net ion-exchange capacity of the membrane can be varied from zero to ca. 2.0 meq/g, either cationic or anionic. Homogeneous membranes are characterized by unusually high water and gas permeabilities and permeabilities to water and soluble solutes which can be controlled by adjustment of gel water content and ion-exchange capacity. Anisotropic membranes can also be prepared which are high flux molecular ultrafilters for solutes as small as sucrose. The anisotropic membranes have found widespread use in biology for fractionation, concentration, and purification of biopolymers. Homogeneous membranes show promise as analogues for biological membranes. A number of applications are being evaluated in medicine and surgery. These include: vascular grafts, antithrom-bogenic coatings for plastic prostheses, contact lenses, corneal implants, and surgical adhesives. In addition, polyelectrolyte complex membranes are showing considerable promise for artificial kidneys and blood oxygenators.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 165-171 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A quantitative method for determining residual ethylene oxide in plastic and rubber catheters using gas-liquid chromatography has been developed. Tests on ethylene oxide stabilized catheters indicated that the amount of ethylene oxide in the catheters decreased as a function of aeration time up to 48 hr. After this period, a steady concentration of ethylene oxide in the catheters appeared to have been reached up to one week's testing.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 183-184 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 187-199 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A rapid mixing and sampling technique was used to study the permeability characteristics of semipermeable aqueous microcapsules (artificial cells). Urea, creatine, creatinine, uric acid, glucose, sucrose, and salicylic acid equilibrated rapidly across nylon microcapsules of 207 μ diameter (e.g., T 1/2 for urea of 3.4 sec). From these results the permeability constants were calculated (e.g., P for urea of 2 × 10-4 cm/sec). Very much the same permeability constants were found for collodion microcapsules. The equivalent pore radius of the membrane of the nylon microcapsules were estimated to be 18 A.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 209-214 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The critical need for purchase specifications for implantable biomedical materials is the focus of this contribution. The elements in development of such specifications are presented with specific reference to a widely used high polymer, polytetrafluoroethylene. A specification for sheet or film of this plastic, as instituted by a major urban hospital, is presented in detail.
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Previous observations of pseudointimal organization within impermeable cardiovascular prostheses indicated that rapid spontaneous healing was dependent upon proximity of host vascular tissue at the suture line. Autologous connective tissue fragments were prepared from skeletal muscle biopsies by blender-mincing muscle tissue. The fragments were embedded in the fabric used to line the inner wall of arterial prostheses. A tightly fitting piston was drawn through the prosthesis, forcing the suspended tissue fragments to flow around the piston and become entwined in the loops of the velour fabric. The arterial prostheses prepared in this way were inserted as replacements for segments of canine abdominal aorta. This in vivo culture system supported cellular proliferation and pseudointimas healed uniformly. Pseudointimas of paracorporeal pumps in operation for as long as 5 weeks did not show signs of healing. The same principle of filtration of tissue fragments into a lining fabric was applied to diaphragms of left ventricular bypass pumps. This type of paracorporeal pump supported in vivo culture of implanted fragments.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 215-230 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Maximum extraction stress and integrated extraction work were measured for sutures implanted for 3, 7, and 14 day periods. Six common non-absorbable sutures, representative of braided and monofilamentary forms, were implanted subdermally and were used for cutaneous incision closure with purebred pointer dogs. The data show: (1) Braided sutures, polyester/Teflon, silk-type B, and silk-silicone interacted with peripheral tissue to a significantly greater degree than the monofilamentary types, nylon, polypropylene, and polyethylene; (2) polyester-Teflon braided suture interacted to a lesser degree than the other braided sutures; (3) the relatively intense interaction of plain silk and silicone-treated silk appears to reflect the combined effects of mechanical aspects of braiding and of biochemical response; and (4) all braided sutures swelled over the implantation periods with as much as a 70% increase in diameter after 14 days for silk.
    Additional Material: 13 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 237-243 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A hydrophilic plastic material (USA trademark Hydron), developed by Wichterle and Lím, was used as a sponge for augmentation of breasts in the clinic for plastic surgery. The preparation of the prosthesis and the operational procedures are described.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 231-235 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: ATP-diphosphohydrolase, trypsin, and chymotrypsin have been insolubilized by lattice-entrapment using hydrophilic polyacrylamide gel and hydrophobic Silastic matrices. The entrapped enzymes were stable and unaffected by washing or wet storage. Thermal inactivation properties of polyacrylamide-entrapped ATP-diphosphohydrolase were different from those of the same enzyme in solution. Several substrates were used for each of the proteolytic enzymes. Esterase activities of both trypsin and chymotrypsin were unaltered by entrapment within Silastic. The entrapment of enzymes and other active proteins is potentially of consequence in continuous-flow substrate conversion systems. Silastic with a surface proteolytic activity derived from an entrapped enzyme is of possible medical utility for implantation elements.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 279-279 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: A careful solvent-exchange procedure followed by liquid-phase reaction of ethyleneimine with cellulose film in a nonpolar solvent provides an effective method of uniformly aminoethylating cellulose. The protonated aminoethyl groups on the cellulose can then ionically bind heparin, a blood anticoagulant. Heparinized aminoethylated cellulose tubing at low levels of aminoethylation (ca. 0.2-0.3% nitrogen) exhibited excellent antithrombogenic properties as well as excellent mechanical strength properties. The in vitro tests demonstrated indefinitely long whole-blood clotting times with normal thrombin times. In the in vivo experiments, the heparinized aminoethylated cellulose tubing provided extended patency when implanted intravascularly in the regions of low blood flow rate (infra renal inferior vena cava of dogs). A principal use of this film is in the artificial kidney.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 377-387 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Symplexes of proteins were taken for comparison with biological structures like the skin of mammals. Particles of these symplexes were set into regular order by diffusing and fixing polyvalent metal ions of protons, yielding anisotropic membranes with some properties of extracellular strucutres. Determination of the symplex optimum allowed a comparison of the properties with different acid partners. Four fifths of the amino groups of the scleroproteins that could be titrated by monomeric acids could be bounded by the polyacids. In a neutral medium, all symplexes behave like coherent polyamphiions with the behavior of long chain molecules. Swelling and dissolving of mammalian skin desintegrates the scleroproteins, partly down to the primary helix. These proteins with polyuronic acids such as alginic acid in form of a symplex did not give individual or specific reactions when implanted into the living organism but were slowly decomposed by unspecific proteases.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 2 (1968), S. 389-399 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The microprobe analyzer has proved to be a valuable tool in investigation of dental and medical materials problems, and the results of a number of studies are described. Interesting aspects of the amalgam-tooth interface have been examined and dental calculus compostion has been determined. Surgical implant studies have included evaluation of appliance alloys and failure analysis of surgical devices.
    Additional Material: 14 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...