  • 1
    Publication Date: 2004-12-03
    Description: This paper reports a new balance for the measurement of three components of force - lift, drag and pitching moment - in impulsively starting flows which have a duration of about one millisecond. The basics of the design of the balance are presented and results of tests on a 15 deg semi-angle cone set at incidence in the T4 shock tunnel are compared with predictions. These results indicate that the prototype balance performs well for a 1.9 kg, 220 mm long model. Also presented are results from initial bench tests of another application of the deconvolution force balance to the measurement of thrust produced by a 2D scramjet nozzle.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Shock Tunnel Studies of Scramjet Phenomena 1993; p 107-112
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-24
    Description: The concept of the well-known Langley plot technique, used for the calibration of ground-based instruments, has been generalized for application to satellite instruments. In polar regions, near summer solstice, the solar backscattered ultraviolet (SBUV) instrument on the Nimbus 7 satellite samples the same ozone field at widely different solar zenith angles. These measurements are compared to assess the long-term drift in the instrument calibration. Although the technique provides only a relative wavelength-to-wavelength calibration, it can be combined with existing techniques to determine the drift of the instrument at any wavelength. Using this technique, we have generated a 12-year data set of ozone vertical profiles from SBUV with an estimated accuracy of +/- 5% at 1 mbar and +/- 2% at 10 mbar (95% confidence) over 12 years. Since the method is insensitive to true changes in the atmospheric ozone profile, it can also be used to compare the calibrations of similar SBUV instruments launched without temporal overlap.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Geophysical Research (ISSN 0148-0227); 100; D2; p. 2997-3004
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2004-12-04
    Description: An improved 4 to 18 micron array camera system was developed at NASA Goddard SFC for astronomical photometry, using an Aerojet Electro Systems Corp. 16 x 16 Si:Bi accumulation mode charge injection device (AMCID) which could be suitable for eventual low-background spaceflight applications. An astronomical observing program using this device was carried out as a collaboration between NASA Goddard (Infrared and Radio Astronomy Branch and Micro Electronics Branch), the Harvard/Smithsonian Center for Astrophysics, and Steward Observatory of the University of Arizona. In 1983 the camera system was revised, and a new Aeroject Si:Bi array with 16 x 16 active pixels was obtained from NASA/Ames Research Center as part of a new scientific collaboration between the Ames and Goddard infrared array research groups. The 16 x 16 device had sufficiently good sensitivity, uniformity and noise characteristics to be used for successful observations at the Mt. Lemmon 60 and 61 inch telescopes in May 1983. Complete laboratory characterization of the 16 x 16 array was carried out in summer of 1983. Initial results indicate that this detector has sensitivity and noise characteristics comparable to other devices from the same generation of Aerojet arrays.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Ames Research Center, Infrared Detector Technology Workshop; 12 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2006-06-26
    Description: Results of an assessment of the public risk associated with the release of carbon fibers from crash-fire accidents of civil aircraft having carbon composite structures are presented. The overall national impact is shown to be extremely low in 1993. Personal injury is found to be extremely unlikely. Based on these findings, the risk of electrical failure from carbon fibers should not prevent the exploitation of composites in aircraft, and additional protection of aircraft avionics to guard aginst carbon fibers is unnecessary.
    Keywords: COMPOSITE MATERIALS
    Type: Selected NASA Res. in Composite Mater. and Struct.; p 183-234
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2006-06-26
    Description: A fatigue analysis technique developed to predict damage growth in notched laminates is described. Features of the analysis include: criteria to relate matrix failure to cyclic stresses in and between plies; correlation of delamination growth with strain-release rate; and in-plane shear modulus change is related to cyclic shear stresses. A simplified finite element model is used to determine stresses in laminates that contain matrix damage. Failure criteria are integrated with the finite element model to form the fatigue analysis.
    Keywords: COMPOSITE MATERIALS
    Type: Selected NASA Res. in Composite Mater. and Struct.; p 79-106
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2006-06-26
    Description: The damage tolerance of composites was investigated. Results show that severe degradation in material strength may occur due to impact damage and that reduced strain allowables should be considered to compensate for possible impact damage. The mechanisms of failure involved in impact so that local damage will be reduced and arrest of propagating fracture initiated at impact locations are examined. Compression strength reductions for damage due to impact by a 1.27 cm diameter spherical projectile in thick laminates representative of wing skin panels are presented. Also discussed are the results of concepts recently evaluated to improve damage tolerance. These concepts range from improvements at the materials level to advanced structural configurations designed to arrest or limit the growth of propagating fractures. The results indicate that substantial improvements in the damage tolerance of graphite-epoxy composite structures can be achieved through the proper combination of materials and structural design.
    Keywords: COMPOSITE MATERIALS
    Type: Selected NASA Res. in Composite Mater. and Struct.; p 107-142
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2006-06-26
    Description: Progress in the development of verified design technology for generic advanced-composite structural components loaded in compression is reported. Generic structural configurations material systems and load ranges of interest for a given application were investigated using structural procedures, structural analysis procedures, and laboratory testing of structural specimens. Both flat and curved composite compression panels that are designed either to be buckling resistant or to have postbuckling strength depending on the expected application of the panels were considered.
    Keywords: COMPOSITE MATERIALS
    Type: Selected NASA Res. in Composite Mater. and Struct.; p 35-78
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2006-06-26
    Description: The degree of notch sensitivity of composites in compression and whether their failures can be predicted over a wide range of plate and hole sizes. The notch sensitivity of composites is investigated by comparing actual failure loads of laminates with circular holes, with the extreme failure that would be expected from an ideal notch insensitive material and from an ideal notch sensitive material. The predictability question is addressed by applying the point stress failure criterion to a wide range of plate widths and hole sizes and comparing with available experimental data. The severity of impact is explored by comparing strength reductions resulting from impact with those resulting from comparable size circular holes. Finally, comparison is made of the differences to be expected from the effects of cracks and circular holes on failure strength.
    Keywords: COMPOSITE MATERIALS
    Type: Selected NASA Res. in Composite Mater. and Struct.; p 1-33
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2006-02-14
    Description: The use of laser holography for measuring the distortion of antennas under space simulation conditions is described. The subject is the so-called double exposure procedure which allows to measure the distortion in the order of 1 to 30/micrometers + or - 0.5 per hologramme of an area of 4 m diameter max. The method of holography takes into account the constraints of the space simulation facility. The test method, the test set up and the constraints by the space simulation facility are described. The results of the performed tests are presented and compared with the theoretical predictions. The test on the K-Band Antenna e.g., showed a distortion of approximately 140/micrometers + or - 5/micrometers measured during the cool down from -10 C to -120 C.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center 13th Space Simulation Conf.; p 309-319
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2006-02-14
    Description: Conventional schemes for digitizing large volumes of photographic data are far too costly and time consuming to encourage the undertaking of the ambitious projects using traditional technology. There is a distinct need for fast digitizing systems such as could be derived from development of large format, optically multiplexed CCD systems designed to address these problems. The use of CCD chips for data handling and the capability of using polaroids in the optical path for reduced light scattering are discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 419-427
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: Parameters of the UK 1.2 meter Schmidt telescope are described. Plates taken with this instrument are in two categories, those for systematic sky surveys and those taken at the request of research users. A collaborative project with the European Southern Observatory was undertaken to obtain a two-color survey of the sky south of -20 deg declination to complement the Palomar survey. A near infrared survey of the Galactic Plane and the Megallanic Clouds is being done. The area south of -20 deg and the zone between 0 deg and -15 deg are also being surveyed. Pending a decision on survey parameters, all available A quality prism plates are being retained to form a basis for systematic survey. Nearly half the plates taken on a service basis for the UK astronomical community are to fulfill nonsurvey requests. Plates taken for surveys which are not of A grade quality are also made available for research purposes.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 379-385
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Publication Date: 2006-02-14
    Description: Some software facilities used mainly for information retrieval and analysis at the Padova-Asiago Observatory are discussed. These facilities help guest and resident astronomers to make easier the preparation of plate measurements. The problems connected with the creation, use and management of a data base in a scientific (astronomical) environment are reviewed on the basis of the experience gathered during the last three years. The development plan of the user session environment and its possible applications in a computer network are briefly sketched.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 361-369
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: A 256 diode-array will be installed as detector on the ESO OPTRONICS S-3000 measuring machine in order to increase the acquisition rate. A high intensity LED will be used as light source in a pulse mode. The data will be stored on a random access mass storage device as density values for later education. The scanning time for a 30 cm x 30 cm plate with a step size of 10 micron will be less than 10 hours while the dynamic range of the data is expected to be 2.5 density units with an offset of at least 1 unit.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 317-328
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Publication Date: 2006-02-14
    Description: The design and performance of the automated photographic measuring facility at Cambridge is described. It consists of a precision laser scanning microdensitometer connected to a series of computers that process the data on-line. Plates up to 350 mm square can be measured. The microdensitometer samples the plate to 12 bit accuracy at a speed of 230,000 samples/second. The positional accuracy is better than a micron. Other features include platen rotation and automatic focus.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 277-288
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The expected performance of the Minnesota automated dual-plate scanner (APS) is discussed with regard to photometry, position measurement accuracy, and ability to classify images. In addition, a fast algorithm for calculating image parameters is described.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 267-276
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Publication Date: 2006-02-14
    Description: Various aspects of the performance of the PDS 1010A microdensitometer are described. The primary points in an upgrade propsal for the unit are outlined. Photometric instabilities in the PDS are mentioned.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 129-134
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: Minor modifications of electronic components in the PDS 1010A microdensitometer are discussed. The operational requirements and performance limitations of the PDS are noted. Replacement of the photomultiplier and front-end analog circuitry significantly improved the photometric performance of the PDS. The improvement in density repeatability is marked, and the permissible density slew speed is greatly increased.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 121-128
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Publication Date: 2006-02-14
    Description: High Altitude Observatory HAO microdensitometer undergoes monthly testing to assure its consistent performance. These tests check positional and photometric stability at the 10 micron aperture level. The HAO test procedure is designed to run without operator intervention following initial configuration of the microdensitometer for each subprocedure. Specialized test software is resident in the PDP 8. The operator selects the proper subprocedure by entering commands. Once computer control is established, it is not relinquished until the test is complete.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Astron. Microdensitometry Conf.; p 19-34
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Publication Date: 2006-02-14
    Description: A number of diagnostic tests are developed for the Photometric Data System PDS 2020G microdensitometer to monitor its performance and to isolate various electromechanical problems. A number of tests which help to diagnose problems with the photometer, positional accuracy and data collection are described. The tests include: (1) scanning a razor blade edge to study the response of the photometer and zero point losses in the coordinate system, (2) scanning a long straight line to evaluate the drunkness of the stage motions, (3) scanning photometric step wedge calibrations to study the response of the photometer, and (4) measurement of a series of high signal to noise plates of the same region of the sky to evaluate the overall performance of the microdensitometer. A variety of electronic tests to isolate electromechanical problems are also performed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 3-18
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The behavior of ruled and holographic gratings with various coatings after extended exposure to the space environments was examined. The coatings and differentiating between the influences of vacuum and solar illumination were examined. In the past, several ruled and holographic gratings with various coatings were successfully flown on rocket experiments. Future utilizations of such gratings are considered for the Space Telescope and for various Spacelab projects under development. The techniques which is used to replicate gratings can also be used to obtain a wide range of lightweight optical components, including sophisticated aspherical, highly polished mirrors.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Langley Research Center Long Duration Exposure Facility (LDEF); p 163-164
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Publication Date: 2006-02-14
    Description: Electro-optic holographic recording systems were developed. The spaceworthiness of electro-optic crystals for use in ultrahigh capacity space data storage and retrieval systems are examined. The crystals for this experiment are included with the various electro-optical components of LDEF experiment. The effects of long-duration exposure on active optical system components is investigated. The concept of data storage in an optical-phase holographic memory is illustrated.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Langley Research Center Long Duration Exposure Facility (LDEF); p 152-153
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Publication Date: 2006-02-14
    Description: The specific scientific objectives of this experiment are to measure the spatial distribution, size, velocity, radiance, and composition of microparticles in near-Earth space. The technological objectives are to measure erosion rates resulting from microparticle impacts and to evaluate thin-foil meteor 'bumpers'. The combinations of sensitivity and reliability in this experiment will provide up to 1000 impacts per month for laboratory analysis and will extend current sensitivity limits by 5 orders of magnitude in mass.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Langley Research Center Long Duration Exposure Facility (LDEF); p 117-120
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Publication Date: 2006-04-12
    Description: Research on three classes of materials that show potential for allowing significant increases in operating temperatures in gas turbine engines is discussed. Monolithic ceramics, ceramic matrix composites, and carbon-carbon composites are discussed. Sintering, hot pressing, and densification are discussed.
    Keywords: COMPOSITE MATERIALS
    Type: NASA. Langley Research Center Advan. Mater. Technol.; p 275-292
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-04-12
    Description: The fabrication of several composite structural articles including DC-10 upper aft rudders, L-1011 vertical fins and composite biomedical appliances are discussed. Innovative composite processing methods are included.
    Keywords: COMPOSITE MATERIALS
    Type: Advan. Mater. Technol.; p 115-140
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Publication Date: 2006-04-12
    Description: Manufacturers are developing composite versions of structural components on existing aircraft. Development involves testing of various material options before selecting one and then extensive testing to develop an adequate data base of material strength and stiffness properties. Design options are narrowed through analysis and a varied spectrum of development tests on small and large subcomponents. In parallel with this, a suitable production process including economical ply preparation and cure at high temperature and pressure is evolved, tools are designed and fabricated, and full scale components are then manufactured for ground qualification tests, flight tests, and airline service. The various tests include many that are required by the FAA for flight certification, which must precede airline service. Inspection and repair methods to insure adequate maintenance in service are also developed.
    Keywords: COMPOSITE MATERIALS
    Type: Advan. Mater. Technol.; p 1-28
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Publication Date: 2006-04-12
    Description: The fatigue, fracture, and impact behavior of composite materials are investigated. Bolted and bonded joints are included. The solutions developed are generic in scope and are useful for a wide variety of structural applications. The analytical tools developed are used to demonstrate the damage tolerance, impact resistance, and useful fatigue life of structural composite components. Standard tests for screening improvements in materials and constituents are developed.
    Keywords: COMPOSITE MATERIALS
    Type: Advan. Mater. Technol.; p 91-114
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-06-04
    Description: The active cavity radiometer (ACR) experiment on the Spacelab 1 mission to measure the total solar irradiance is discussed. Short and long term variations in the total solar output of optical energy are studied. Solar total irradiance observation provides information on the solar cycle and other long term trends in solar output that are of climatological significance as well as short term solar physics phenomena. The interaction of solar radiation with the Earth's atmosphere, oceans, and land masses provides the primary driving forces for the formation of weather systems and the determination of climate. Astrophysical measurements determine the total energy flux. The principal role of the ACR observations support extended solar irradiance experiments on free flying satellites. Solar irradiance measurements are important in the establishment of the radiation scale at the solar total flux level in the international system of units (SI).
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center Spacelab Mission 1 Expt. Descriptions; 4 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-06-04
    Description: The study of galactic and faint extragalactic extended sources and peculiar ultraviolet objects by a very wide field of view camera, operated in the ultraviolet photometric and spectrometric modes is discussed. The photometric mode is direct photography through filters for observation of the following sources: (1) large scale distribution of ultraviolet radiation in the Milky Way; (2) diffusion of the galactic light above the galactic plane and in front of the large absorbing clouds; (3) the optical emission of the interstellar matter; (4) stars, and starlike objects with diameters less than 3 arc minutes. In the spectrometric mode (nebular spectrograph) the light from the center of the photometric field is concentrated on a slit covering 10 degrees by 10 arc minutes on the sky.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center Spacelab Mission 1 Expt. Descriptions; 3 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-06-05
    Description: The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center Spacelab Mission 1 Expt. Descriptions; 2 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-06-04
    Description: A test of the mapping capabilities of high resolution space photography taken at the resolution limit of image motion on large film format is planned. The metric camera system and its planned operation are described.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center Spacelab Mission 1 Expt. Descriptions; 4 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-06-04
    Description: Photography and measurement of cloud-like structures of bright parallel bands observed in near infrared photography of the night sky is planned. The instrument is described and the purpose of the experiment summarized.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center Spacelab Mission 1 Expt. Descriptions; 2 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-06-04
    Description: High resolution infrared spectroscopic observations of the Earth's limb in the wavelength range characteristic of the vibrational-rotational lines of trace atmospheric constituents is planned. The instrument and its operation and the purpose of the experiments are summarized.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center Spacelab Mission 1 Expt. Descriptions; 3 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The counter is a static thermal diffusion chamber which has been modified to include an optical system for the determination of droplet concentration by the measurement of scattered light. The determination of concentration is made by measurement of the peak scattered light signal from the cloud of growing droplets which is a function of both the droplet concentration and chamber supersaturation. Because the formation of the peak is related to the rate of growth of the droplets and sedimentation, both of which are determined by supersaturation, the system calibration can be uniquely determined by comparison with an absolute counter such as a static diffusion chamber with a photographic recording system.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 40-41
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Publication Date: 2006-02-14
    Description: Unlike typical CCN counters, this device counts the numbers of water droplets condensed on aerosol particles sampled on a microcover glass at various different relative humidities. The relative humidities ranged from 75 percent to a calculated value of 110 percent. A schematic of the apparatus is shown. The individual CCN can be identified in an optical micrograph and scanning electron micrograph and may be inspected for their chemical composition later.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 35-36
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Publication Date: 2006-02-14
    Description: In performing the data analysis of the measurements achieved during the Workshop with the device, a global approach was preferred rather than an individual analysis, in order to illustrate some main characteristics in the behavior of the device with respect to a mean behavior resulting from a general survey of all the equipments involved in each experiment. The device tends generally to overestimate the CCN concentrations measured near the high supersaturations and sometimes underestimates the concentrations close to 0.1% or 0.2% of supersaturation. Despite the fact that it belongs to a type of static diffusion chamber, it shows, however, similar spectra to those obtained with other types of chambers (continuous flow diffusion chamber and haze chamber).
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 17-19
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Publication Date: 2006-02-14
    Description: The group's CCN counter is described. It is a static, horizontal, parallel plate thermal gradient diffusion chamber. Examples of the application of the CCN are presented and include the CCN spectra measured during the winter of 1978-79 near Elk Mountain, Wyoming. Comparisons of droplet concentrations derived from upwind CCN spectra are covered.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 11-13
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Publication Date: 2006-02-14
    Description: A parallel beam of X-rays (approximately monoenergetic) passing through a rectangular slit and scattering from two flat mirrors comprise the X-ray test. The two mirrors are arranged in a periscope geometry so that the final reflected beam is parallel to the incident beam but displaced laterally by given amount. One of the detectors used to intercept the reflected X-rays is a one dimensional gas-filled proportional counter which is sensitive to the position (in 1 dimension) at which the X-rays are incident within its detecting "window". The total length of the anode wire of the proportional counter is 120 mm and this length can be divided electronically into a maximum of 1,024 parts. Hence, the output of an experimental run would be the number of incident X-rays that registered on each of the 1,024 channels. Each channel would represent an X-ray at a different spatial location and, hence, at a different scattering angle. In order to look at a wider range of scattering angles, the detector is placed on an optical table which can be rotated.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Alabama Univ. in Huntsville The 1981 NASA(ASEE Summer Fac. Fellowship Program; 6 p
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Publication Date: 2006-02-14
    Description: The size distribution was measured in the size range between 0.0057 and 0.57 micrometer radius. A description of the instrumentation and data analysis is given, together with the measured size distributions calculated for 23 experiments.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 69-78
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Publication Date: 2006-02-14
    Description: The experiments performed at the Workshop were undertaken to confirm the calculated sample volume, determine the usable range of supersaturation, and minimum detectable size. Comparison of absolute CCN concentrations with other state-of-the-art continuous flow diffusion chambers at supersaturations near 1 percent indicated that the volume used produced CCN concentrations well within the range of CCN concentrations determined at the workshop. This agreement is interpreted to mean the sample volume was correct. Direct measurements of the beam geometry done in the laboratory indicated a factor of 4-5 error. This error is apparently due to the larger apparent visible beam diameter versus the actual usable beam diameter given the droplet illumination, chamber optical geometry, microscope optics and film characteristics.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 44-45
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Publication Date: 2006-01-16
    Description: A multi-channel chopper system designed and built to stringent specifications is providing an excellent performance for a total ozone mapping spectrometer (TOMS). State of the art machining technology, suitable material selection, and a way to hold and position the slit plate resulted in the instrument's better than expected performance. A shutter method used for internal calibration allows compensation for the occurrence of an unlikely wavelength shift during testing, launch, or during the orbiting life of the instrument. The TOMS is part of a payload on Nimbus 7 launched on October 24, 1978.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center The 15th aerospace Mech. Symp.; p 63-75
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Publication Date: 2006-02-14
    Description: A brief comparative description is made of the chambers. Overall, comparisons for the various types of experiments - monodisperse, polydisperse and ambient aerosol - showed agreement among these chambers to within 15% in most cases. A careful analysis of the results indicated that a proper accounting of certain parameters would bring about much closer agreement among four of these instruments.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: The Third Intern. Cloud Condensation Nuclei Workshop; p 79-84
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: In the IHC the critical supersaturation is inferred from the measurement of the size of particles which have grown to their equilibrium size at exactly 100 percent RH. The largest size channel corresponds to a critical supersaturation of 0.014 percent. The growth time required for particles of this size to reach their equilibrium size exceeds the 110 second residence time in the IHC. Since the supersaturation spectrum is always very steep in this region, the contribution of these larger particles which have not yet attained their equilibrium size to smaller size channels is negligible. However, failure of these particles to reach their equilibrium size could result in a significant lowering of the count in the size channel corresponding to the smaller critical supersaturation.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 42-43
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The chamber geometry and optical arrangement are described. The supersaturation range is given and consists of readings taken at five fixed points: 0.25%, 0.5%, 0.75%, 1.0%, and 1.25%. The detection system is described including light source, cameras, and photocell detectors. The temperature control and the calibration of the chamber are discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 26-27
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Publication Date: 2006-02-14
    Description: The NRL thermal gradient diffusion cloud chamber (TGDCC) consists of two plates 7.5 cm in diameter separated by 1.25 cm and covered with saturated filter paper. The cylindrical wall separating the plates is glass. The top plate is at room temperature and the bottom plate is cooled with a thermoelectric cooler. The temperature difference is measured with several sets of thermocouples. The CCN concentration was determined from the video recording. This procedure of averaging the maximum count obtained on several successive recordings at the same supersaturation results in concentrations which are somewhat higher than concentrations calculated from an average across the plateau.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 14-16
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: Two instruments were used to size dry aerosols for the CCN experiments: the Naval Research Laboratory (NRL) instrument which uses an electrical mobility analyzer to separate the aerosol size fractions and a diffusion chamber to grow and count the particles and the University of Wyoming (WYO) aerosol monitoring system. Measurements from these two systems were usually found to be in agreement during the CCN Workshop. Two examples are presented to compare aerosol size distribution measurements of the two instruments: experiment 8 (monodisperse NaCl) and experiment 27 (polydisperse AgI). Differential (dN/dR) and cumulative plots are shown for both instruments for experiment 8 and experiment 27; also shown are Aitken particle measurements for comparison.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 106-107
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    Publication Date: 2006-02-14
    Description: Nine CCN counters of the static diffusion (SDC) type were compared with one another and with continuous flow diffusion (CFD) chambers. The nine SDCs showed a considerable amount of variation, largely attributable to newness and/or lack of prior calibration of some units. The five more consistent instruments agreed quite well, to within at least 20 percent of the NRL mobility analyzer and to within 10 percent at 1 percent supersaturation. There was satisfactory agreement between the more reliable SDC and CFD chambers.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 57-63
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The diffusion tube was designed to operate below about 0.25 percent of water supersaturation. It is simply a long tube lined on the inside with a damp chamois cloth, and heated isothermally to a few degrees centigrade above the incoming air. The diffusion coefficient for water vapor is slightly larger than that for heat, making it possible to supersaturate the airflow. This is the same principle by which transient supersaturations may occur in parallel plate cloud chambers. Only the diffusion of vapor and heat from the walls into the moving air are considered.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 37-39
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    Publication Date: 2006-02-14
    Description: The chamber is a thermal gradient diffusion type with the upper plate at room temperature and the lower plate thermoelectrically cooled. The light from a 25W projector bulb is focused in a beam of approximations 1x3 mm in the central part of the chamber. The light scattered by drops is viewed in the forward direction (40 deg) by a microscope and a sensitive photodetector. Experiments were performed to relate the peak output from the photocell with the maximum number of drops in the beam recorded photographically. The microscope is used to check the calibration at low concentrations of CCN. The results of the experiments and the performance of the counter are reported.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Desert Research Inst. The Third Intern. Cloud Condensation Nuclei Workshop; p 33-34
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Publication Date: 2006-02-14
    Description: One of the principal advantages of electrography when compared to photography is the nearly linear relationship between source intensity versus resulting image density. This property allows for simplified and more accurate photometric calibration and permits a certain degree of extrapolation of the calibration to beyond the limits of the faintest photoelectric standard on an exposure. The desires to extract quantitative photometric information from electrographic (or photographic) negatives and to convert this information into a digital format for computer analysis or enhancement led to the widespread use of scanning microdensitometers to perform this A-to-D conversion. Therefore it is of vital importance to understand and, if practical, to avoid any nonlinearities which may be introduced during microdensitometry of electrographic emulsions.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 429-431
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    Publication Date: 2006-02-14
    Description: The scanning of a direct plate with the automatic plate measuring machine which results in the automated selection and description of images is described. The selection of QSO candidates based on color-color diagrams constructed from the APM image data and the analysis of APM raster data for QSOs selected visually from objective prism plates are also discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 417-418
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The fundamental limitations of microdensitometers are reviewed and the design of a high microdensitometer described. The system will digitize to 16 bits in transmission at a speed of 100 kHz using a laser beam moving over the emulsion. Other features are automatic platen rotation and autofocus. The cost will be of order $200,000.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 333-341
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: A new photographic measuring machine is under construction at the Paris Observatory. The amount of transmitted light is measured by a linear array of 1024 photodiodes. Carriage control, data acquisition and on line processing are performed by microprocessors, a S.E.L. 32/27 computer, and an AP 120-B Array Processor. It is expected that a Schmidt telescope plate of size 360 mm square will be scanned in one hour with pixel size of ten microns.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 329-332
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    Publication Date: 2006-02-14
    Description: A diode-array based image digitizer manufactured by the Eikonix Corp. was tested to see if it can be adapted to the exacting requirements of astronomical densitometry. As the device is presently configured, a dynamic range of 400:1 can be achieved routinely, with a positional accuracy of 2 microns or better. An area of 2048 X 2048 pixels can be scanned in about 5 minutes. Preliminary tests indicate that several relatively simple enhancements can improve both the photometric and the positional accuracy of the device.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 307-315
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: Motivations for construction of a next generation microdensitometer (NGM) are presented and their effect on the NGM design is discussed. A prototype of such an engine has been constructed at KPNO. Its design and performance is reviewed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 291-305
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The motivations for constructing a special purpose built microdensitometer are explored. The salient points of some of the microdensitometers are described and the advantages and disadvantages of the system in comparison to a PDS machine are outlined. The principal gain is in speed though at the expense of loss in dynamic range. The effects on the astronomical results are demonstrated. The astronomical results already obtained with these machines and from ongoing projects are described. It is shown that there is a large class of important astronomical problems which can be tackled by these machines but which are not feasibile on the PDS because of the speed of the machine.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 209-228
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    Publication Date: 2006-02-14
    Description: The necessity to incorporate several hardware changes to optimize the Yale PDS 2020G microdensitometer for photometric and astrometric research are discussed. The properties of a new high speed photometer and a positional calibration system are described. The new photometer incorporates a high speed logarithmic analog to digital converter with more than 10 times the resolution of the former system and a cycle time of approximately 50 usec. The positional calibration system monitors the drunkenness of the stages with respect to fixed index lines and enables the correction of the +/- 5 micro stage errors to an accuracy of better than 1 micro.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 151-161
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: The astrometric and photometric performance of the PDS 1010A microdensitometer are discussed, including the tests used for checking it. The instrument was shown to satisfy operational requirements for photometric measurements of astronomical plates with respect to dynamic range and stability.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 89-95
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Publication Date: 2006-02-14
    Description: The results of several parametric studies carried out on the Marshall Space Flight Center (MSFC) Photometric Data System PDS-10 microdensitometer are summarized for the purposes of documenting the operation and limitations of the system for inhouse research and to provide a bench mark for comparison with other microdensitometers. The results are grouped into four general areas. These are: (1) system overall stability to drift, (2) photometric linearity and noise, (3) reproducibility, and (4) scanning performance. Test data taken in order to evaluate the interdependency of scan speed, noise and position are included. Shown also are results of tests for system stability, reproducibility, stray light and PMT settling time.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Marshall Space Flight Center Astron. Microdensitometry Conf.; p 71-88
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Publication Date: 2006-02-14
    Description: The performance of densitometers used for photometric data reduction of high dynamic range electrographic plate material is analyzed. Densitometer repeatability is tested by comparing two scans of one plate. Internal densitometer errors are examined by constructing histograms of digitized densities and finding inoperative bits and differential nonlinearity in the analog to digital converter. Such problems appear common to the four densitometers used in this investigation and introduce systematic algorithm dependent errors in the results. Strategies to improve densitometer performance are suggested.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 45-58
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: Various perturbations which occurred during the operation of a PDS 2020 GM microdensitometer are reviewed. The effects of elevated temperature, vibration, transient electrical noise, and photometric perturbations are briefly discussed. Sample astronomical results from the PDS 2020 GM unit are presented.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 97-106
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Publication Date: 2006-02-14
    Description: Digitizing flatfield images produces conditions in the Photometric Data System PDS which cause the measured density to drift by as much as .1 DN during a 10 minute interval. The drift occurs when the PDS, set up in equilibrium at fog level, subsequently scans a reasonably dense region for periods of longer than a few minutes. The drift is manifested primarily as a positive shift in density that is approximately the same for all densities. If the fog level is assumed to be in fact constant and is monitored during scans of flat fields, the PDS drift may be removed by subtracting the difference between the observed fog level and its assumed constant value for each pixel. This function is then smoothed and subtracted, as a function of scan line, from the measured density. The fog level is then adjusted to a standard value by adding a constant. The result is a flattened scan with PDS drift removed to the accuracy within which the fog level drift matches the drift at other levels.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Astron. Microdensitometry Conf.; p 59-69
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Publication Date: 2006-02-14
    Description: The photometric and positional accuracy of a microdensitometer is examined. A calibrating plate with different density areas available is used to determine photometric accuracy. Position accuracy is evaluated by multiple scans of sharp edges and analyzed statistically.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Astron. Microdensitometry Conf.; p 35-43
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-02-14
    Description: Many of the passive experiments flying on LDEF will be significantly enhanced if data are available postflight to indicate the temperature time histories of test materials and other specimens exposed in the experiments. The baseline LDEF approach was to provide postflight calculated temperature histories of experiment boundaries and solar flux data for the mission, which can in turn be used by each investigator to calculate the temperature time histories for critical experiment components. Without in-flight temperature measurements, a substantial uncertainty will exist in the calculated temperatures. The data measured by the themal measurement system (THERM) will significantly improve postflight knowledge of temperatures experienced by LDEF experiments. The THERM data will also be valuable in validating the LDEF thermal design concept and in providing better design data for experimenters on future LDEF missions. The objectives of this experiment are to determine the history of the interior average temperatures of the LDEF for the total orbital mission and to measure the temperatures of selected components and thermal boundary conditions.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Long Duration Exposure Facility (LDEF); p 78-81
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    Publication Date: 2006-02-14
    Description: The objective of this experiment is to determine the effect of various lengths of exposure to a space environment on the mechanical properties of selected commercial polymer matrix composite materials. Fiber materials will include graphite, boron, S-glass, and PRD-49. The mechanical properties to be investigated are orthotropic elastic constants, strength parameters (satisfying the tensor polynomial relation), coefficients of thermal expansion, impact resistance, crack propagation, and fracture toughness. In addition, the effect of laminate thickness on property changes will also be investigated.
    Keywords: COMPOSITE MATERIALS
    Type: NASA. Langley Research Center Long Duration Exposure Facility (LDEF); p 41-43
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Publication Date: 2006-02-14
    Description: The objective is to test different types of materials (laminates, thermal coatings, and adhesives) to determine their actual useful lifetime. These experiments will also make is possible to integrate the histories of the thermal and mechanical characteristics into models of the composite structures. The experiment is passive and is located in one of the boxes in a 12-in.-deep peripheral tray with nine other experiments from France. The box will provide protection for the samples from contamination during the launch and reentry phases of the Long Duration Exposure Facility mission. The experiment revolves around four themes of study: thermal coatings, adhesives, dimensional stability, and mechanical characteristics. The various materials will be arranged in six levels within the box, so only the first level will be subjected to direct solar radiation. Each level will consist of plates from which test specimens will be cut after the mission.
    Keywords: COMPOSITE MATERIALS
    Type: NASA. Langley Research Center Long Duration Exposure Facility (LDEF); p 32-34
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Publication Date: 2006-02-14
    Description: The immediate objectives of this experiment are to understand changes in the properties and structure of materials after exposure to the space environment and to compare these changes with predictions based on laboratory experiments. The experiment consists of 19 subexperiments involving a number of DOD laboratories and contractor organizations. In general, the experimental approach with each of the subexperiments will involve comparison of preflight and postflight analyses. Typical analyses will include the measurement of optical properties (reflectance, transmittance, and refractive index), and macrophysical properties. In addition to measuring changes in the macroscopic properties of the returned specimens, microstructural properties will also be examined. Thus, it may be possible to increase our understanding of the changes induced by the environment. This increased understanding can then be used to predict the performance of materials based on knowledge of the space environment and the results of laboratory tests. This experiment will be a coopperative effort and will provide an opportunity for DOD space programs and laboratories to evaluate materials and components after long exposures to the space environment.
    Keywords: COMPOSITE MATERIALS
    Type: NASA. Langley Research Center Long Duration Exposure Facility (LDEF); p 44-48
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Publication Date: 2006-02-14
    Description: The primary objective of this experiment is to accumulate the needed operational data associated with the exposure of graphite-polyimide and graphite-epoxy material to the environments of space. The experiment will be mounted in two 3-in.-deep peripheral trays. Graphite-polyimide specimens will occupy 1 1/3 trays and the graphite-epoxy specimens will occupy two-thirds of a tray. The experiment approach requires two matched sets of specimens with traceable records that are maintained for materials processing and specimen quality. After fabrication, one set of each test specimen will be sectioned and structurally tested to serve as a data baseline. After the flight, the other set of specimens will undergo extensive measurements of mechanical properties for comparison with the original data baseline. Structural testing of the graphite-polyimide specimens will provide strength and elastic data in tension, compression, and shear. Transverse tension microcracking and crack propagation will be evaluated by photomicroscopy. Structural testing of the graphite-epoxy specimens will include verification of laminate, core, adhesive, and fatigue properties as applied to the design and analysis of the payload bay door. Microcracking and crack propagation will also be analyzed by photomicroscopy.
    Keywords: COMPOSITE MATERIALS
    Type: NASA. Langley Research Center Long Duration Exposure Facility (LDEF); p 38-40
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    Publication Date: 2006-02-14
    Description: This experiment has three objectives. The first and main objective is to detect a possible variation in the coefficient of thermal expansion of composite samples during a 1-year exposure to the near-Earth orbital environment. A second objective is to detect a possible change in the mechanical integrity of composite products, both simple elements and honeycomb sandwich assemblies. A third objective is to compare the behavior of two epoxy resins commonly used in space structural production. The experimental approach is to passively expose samples of epoxy matrix composite materials to the space environment and to compare preflight and postflight measurements of mechanical properties. The experiment will be located in one of the three FRECOPA (French cooperative payload) boxes in a 12-in.-deep peripheral tray that contains nine other experiments from France. The FRECOPA box will protect the samples from contamination during the launch and reentry phases of the mission. The coefficients of thermal expansion are measured on Earth before and after space exposure.
    Keywords: COMPOSITE MATERIALS
    Type: NASA. Langley Research Center Long Duration Exposure Facility (LDEF); p 27-31
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Publication Date: 2006-02-14
    Description: The objective of this experiment is to evaluate the effects of the near-Earth orbital environment on the physical and chemical properties of laminated continuous-filament composites and composites resin films for use in large space structures and advanced spacecraft. The experiment is passive and occupies about one-half of a 6-in.-deep peripheral tray. Specimens of composite materials and polymeric and resin films are arranged above and below the experiment mounting plate to enable both exposure and nonexposure to sunlight. This provides a comparison of the effects of ultraviolet plus vacuum plus thermal cycling and those of vacuum plus thermal cycling on these materials. The experiment tray is thermally isolated from the Long Duration Exposure Facility structure to allow the material specimens to experience a wide range of thermal cycles. Tensile and compression specimens will be used to evaluate the laminated composite materials. A number of the specimens are precut and ready for testing after space exposure, whereas other specimens will be prepared from larger samples.
    Keywords: COMPOSITE MATERIALS
    Type: Long Duration Exposure Facility (LDEF); p 24-26
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Publication Date: 2006-02-14
    Description: Graphite-epoxy composites are promising candidates for structural use in space vehicles because of their high strength and elastic modulus properties. The problem of low fracture toughness was solved by use of recently developed techniques of intermittent interlaminar bonding. Before this material can be adapted for space use, however, confidence must be gained that its mechanical properties are not degraded by exposure to the space environment. The objective of this experiment is to test the effect of extended exposure to a space environment on the mechanical properties of a specially toughened T300/5208 graphite-epoxy composite material. Specimens made by recently developed techniques of intermittent interlaminar bonding will be exposed and afterward tested for fracture toughness, tensile strength, and elastic modulus. The approach of this experiment is to provide a frame on which the specimens can be mounted with their flat sides normal to the Long Duration Exposure Facility radius, each specimen with an unobstructed exposure of about 2 pi sr. The specimens will be mounted so that they neither fracture from high stress nor fail from excessive heating during launch and return.
    Keywords: COMPOSITE MATERIALS
    Type: NASA. Langley Research Center Long Duration Exposure Facility (LDEF); p 19-20
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-04-12
    Description: Confidence in the long term durability of advanced composites is developed through a series of flight service programs. Service experience is obtained by installing secondary and primary composite components on commercial and military transport aircraft and helicopters. Included are spoilers, rudders, elevators, ailerons, fairings and wing boxes on transport aircraft and doors, fairings, tail rotors, vertical fins, and horizontal stabilizers on helicopters. Materials included in the evaluation are boron/epoxy, Kevlar/epoxy, graphite/epoxy and boron/aluminum. Inspection, maintenance, and repair results for the components in service are reported. The effects of long term exposure to laboratory, flight, and outdoor environmental conditions are reported for various composite materials. Included are effects of moisture absorption, ultraviolet radiation, and aircraft fuels and fluids.
    Keywords: COMPOSITE MATERIALS
    Type: Advan. Mater. Technol.; p 335-356
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2006-04-12
    Description: Carbon-carbon materials and new oxidation resistant coating developments are discussed. Potential areas of application are highlighted. A short bibliography of selected references is included that describe carbon-carbon materials and related technology in detail.
    Keywords: COMPOSITE MATERIALS
    Type: Advan. Mater. Technol.; p 293-312
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Publication Date: 2011-08-24
    Description: A sandwich construction, composed of hybrid carbon-glass fiber-reinforced plastic skins and a syntactic foam core, was selected as the design concept for a wind tunnel compressor blade application, where high damage tolerance and durability are of major importance. Beam specimens were prepared from open-edge and encapsulated sandwich panels which had previously been immersed in water at different temperatures for periods of up to about two years in the extreme case. Moisture absorption and strength characteristics, as related to time of exposure to hygrothermal conditions, were evaluated for the sandwich specimens and their constituents (skins and foam). After different exposure periods, low-velocity impact damage was inflicted on most sandwich specimens and damage characteristics were related to impact energy. Eventually, the residual compressive strengths of the damaged (and undamaged) beams were determined flexurally. Test results show that exposure to hygrothermal conditions leads to significant strength reductions for foam specimens and open-edge sandwich panels, compared with reference specimens stored at room temperature. In the case of skin specimens and for beams prepared from encapsulated sanwich panels that had previously been exposed to hygrothermal conditions, moisture absorption was found to improve strength as related to the reference case. The beneficial effect of moisture on skin performance was, however, limited to moisture contents below 1% (at 50 C and lower temperatures). Above this moisture level and at higher temperatures, strength degradation of the skin seems to prevail.
    Keywords: COMPOSITE MATERIALS
    Type: Composites (ISSN 0010-4361); 26; 1; p. 47-61
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-19
    Keywords: COMPOSITE MATERIALS
    Type: NASA Technol. Appl. Team; p 38
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    Publication Date: 2011-08-18
    Description: A unified set of composite micromechanics equations of simple form is summarized and described. This unified set can be used to predict unidirectional composite (ply) geometric, mechanical, thermal and hygral properties using constituent material (fiber/matrix) properties. This unified set also includes approximate equations for predicting (1) moisture absorption; (2) glass transition temperature of wet resins; and (3) hygrothermal degradation effects. Several numerical examples are worked-out to illustrate ease of use and versatility of these equations. These numerical examples also demonstrate the interrelationship of the various factors (geometric to environmental) and help provide insight into composite behavior at the micromechanistic level.
    Keywords: COMPOSITE MATERIALS
    Type: SAMPE Quarterly (ISSN 0036-0821); 15; 14-23
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    Publication Date: 2011-08-18
    Description: Tensile properties of unidirectional Celion 6000 graphite/PMR 15 polyimide composites prepared by hot molding and cold molding processes were measured at room temperature and 316 C, the upper use temperature of the polyimide resin, at both 45 and 90 deg to the fiber axis. The resulting fractures were characterized by scanning electron microscopy and materialographic techniques. Variation in tensile properties with processing history occurred in the elastic modulus and strain to failure for specimens loaded at 90 deg at 316 C, and in the fracture stress, and hence the in-plane shear stress, for those loaded at 45 deg at room temperature. Significant plastic deformation was observed in the 45 deg orientation at 316 C for material produced by both processing methods. In general, fracture occurred by both failure within the matrix and at the fiber-matrix interface; the degree of interfacial failure increased with temperature. Secondary cracking below the primary fracture surface was also observed.
    Keywords: COMPOSITE MATERIALS
    Type: Polymer Composites (ISSN 0272-8397); 5; 179-185
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Publication Date: 2011-08-18
    Description: New frequency calibration tables are required to keep abreast of the resolution attainable by currently available tunable lasers. One key to the generation of tables with requisite accuracy involves accurate heterodyne frequency measurements; another key consists of reliable fitting and analysis. Coordinated activity in NBS involves selection of suitable molecular calibration candidates, their frequency measurement and analysis, and dissemination of the results in the form of frequency calibration tables. Current status of these efforts is described.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: A new extension to optogalvanic spectroscopy, in which electrons detached from negative ions formed in the discharge are observed as a function of incident laser wavelength, has been developed. The determination of the electron affinities of I(-) and Cl(-) atomic ions is described. The potential of the technique for studying the spectroscopy of molecular negative ions is also discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal de Physique (ISSN 0449-1947); 44; C7-461 t
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    Publication Date: 2011-08-18
    Description: Previously cited in issue 5, p. 642, Accession no. A83-16486
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: AIAA Journal (ISSN 0001-1452); 22; 1115-112
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    Publication Date: 2011-08-18
    Description: The design of a high spectral resolution, lambda/delta lambda being approximately 1200 IR, sounder capable of increasing the vertical resolution of atmospheric temperature profiles and achieving a rms accuracy of approximately 1.5 K is discussed. This sounder permits improved determination of meteorological parameters on cloudiness, surface temperature, and air-surface interactions. A set of channels from the high J lines in the R branch of the 4.3-micron CO2 band complemented by a larger set of window, humidity, and temperature channels in the 3.7-, 6.3-, 9-, and 15-micron regions is used. Design and simulation studies show that such a sounder is within the present state of the art.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 979-989
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    Publication Date: 2011-08-18
    Description: This paper presents the conceptual design of an instrument, called the solar disk sextant, to be used in space to measure the shape and the size of the sun and their variations. The instrumental parameters required to produce sufficient sensitivity to address the problems of solar oblateness, solar pulsations, and global size changes of climatic importance are given.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 1235-123
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    Publication Date: 2011-08-18
    Description: Several silicon-carbide fiber reinforced titanium matrix composite systems were investigated to determine composite degradation mechanisms and to develop techniques to minimize loss of mechanical properties during fabrication and in service. Emphasis was on interface control by fiber or matrix coatings. Fibers and matrix materials were sputter coated with various metals to determine the effects of the coatings on basic fiber properties, fiber-matrix interactions, and on composite properties. The effects of limited variations in fabrication temperature on composite properties were determined for composites consolidated by standard press-diffusion-bonding techniques.
    Keywords: COMPOSITE MATERIALS
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Publication Date: 2011-08-18
    Description: A holographic interferometer system has been installed in the NASA Ames 2- by 2-Foot Transonic Wind Tunnel. The system incorporates a modern 10 pps, Nd:YAG pulsed laser which provides reliable operation and is easy to align. The spatial filtering requirements of the unstable resonator beam are described, as well as the integration of the system into the existing schlieren system. A two-plate holographic interferometer is used to reconstruct flow field data. For static wind tunnel models, the single exposure holograms are recorded in the usual manner; however, for dynamic models such as oscillating airfoils, synchronous laser hologram recording is used.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Publication Date: 2011-08-18
    Description: Twenty-four different epoxy resin systems were evaluated by a variety of test techniques to identify materials that exhibited improved impact damage tolerance in graphite/epoxy composite laminates. Forty-eight-ply composite panels of five of the material systems were able to sustain 100 m/s impact by a 1.27-cm-diameter aluminum projectile while statically loaded to strains of 0.005. Of the five materials with the highest tolerance to impact, two had elastomeric additives, two had thermoplastic additives, and one had a vinyl modifier; all the five systems used bisphenol A as the base resin. An evaluation of test results shows that the laminate damage tolerance is largely determined by the resin tensile properties, and that improvements in laminate damage tolerance are not necessarily made at the expense of room-temperature mechanical properties. The results also suggest that a resin volume fraction of 40 percent or greater may be required to permit the plastic flow between fibers necessary for improved damage tolerance.
    Keywords: COMPOSITE MATERIALS
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    Publication Date: 2011-08-18
    Description: Statistical analysis and multiple regression were used to determine and quantify the significant hygrothermomechanical variables which influence the tensile durability/life (cycle loading, fatigue) of boron-fiber/epoxy-matrix (B/E) and high-modulus-fiber/epoxy-matrix (HMS/E) composites. The use of the multiple regression analysis reduced the variables from fifteen, assumed initially, to six or less with a probability of greater than 0.999. The reduced variables were used to derive predictive models for compression and intralaminar shear durability/life of B/E and HMS/E composites assuming isoparametric fatigue behavior. The predictive models were subsequently generalized to predict the durability/life of graphite/fiber-r generalized model is of simple form, predicts conservative values compared with measured data and should be adequate for use in preliminary designs. Previously announced in STAR as N82-14287
    Keywords: COMPOSITE MATERIALS
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    Publication Date: 2011-08-18
    Description: For an investigation of problems of composites at high strain rates with dominant wave propagation effects, such as dynamically loaded composite jet engine blades, the longitudinal, transverse, and in-plane shear properties of unidirectional SP 288/AS graphite/epoxy were measured at various strain rates ranging from quasi-static to over 500/s. The test specimens were rings 10.16 cm in diameter, 2.54 cm long, 6 to 8 plies thick, and with fibers at 0, 90, and 10 deg off-axis. Quasi-static testing was conducted in a fixture which applies hydraulic pressure to the ring specimens, and dynamic testing was conducted by applying an internal pressure pulse through a liquid in a special fixture. Dynamic stress-strain curves are presented. For the 0-deg specimens, the modulus increases with strain up to 20 percent of the static value. The modulus and strength increase sharply in the 90-deg rings with strain rate reaching values two to three times the corresponding static rate.
    Keywords: COMPOSITE MATERIALS
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Publication Date: 2011-08-18
    Description: Previously cited in issue 05, p. 643, Accession no. A83-16685
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: AIAA Journal (ISSN 0001-1452); 22; 557-559
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: The composite material 'buffer strip' concept is presently investigated at elevated temperatures for the case of graphite/polyimide buffer strip panels using a (45/0/45/90)2S layup, where the buffer strip material was 0-deg S-glass/polyimide. Each panel was loaded in tension until it failed, and radiographs and crack opening displacements were recorded during the tests to determine fracture onset, fracture arrest, and the extent of damage in the buffer strip after crack arrest. At 177 + or - 3 C, the buffer strips increased the panel strength by at least 40 percent in comparison with panels without buffer strips. Compared to similar panels tested at room temperature, those tested at elevated temperature had lower residual strengths, but higher failure strains.
    Keywords: COMPOSITE MATERIALS
    Type: Journal of Composite Materials (ISSN 0021-9983); 17; 549-560
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-18
    Description: A simple and inexpensive thermal diffusivity apparatus is described for measurement up to 1600 K. The novel features of apparatus include a light pipe, a long furnace, and a differential thermocouple. A low heat-load sample holder for clamping the sample in a vertical position is also described. The results of measurements on AXM-5Q graphite are reported.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Review of Scientific Instruments (ISSN 0034-6748); 55; 235-237
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Publication Date: 2011-08-18
    Description: The processing and oxidation resistance of fused Al-Si and Ni-Si slurry coatings on ATJ graphite was studied. Ni-Si coatings in the 70 to 90 percent Si range were successfully processed to melt, wet, and bond to the graphite. The molten coatings also infiltrated the porosity in graphite and reacted with it to form SiC in the coating. Cyclic oxidation at 1200 C showed that these coatings were not totally protective because of local attack of the substrate, due to the extreme thinness of the coatings in combination with coating cracks. Previously announced in STAR as N83-27019
    Keywords: COMPOSITE MATERIALS
    Type: Ceramic Engineering and Science Proceedings (ISSN 0196-6219); 4; 757-783
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Publication Date: 2011-08-19
    Description: To analyze the fatigue behavior of a simple composite-to-composite bonded joint, a combined experimental and analytical study of the cracked-lap-shear specimen subjected to constant-amplitude cyclic loading was undertaken. Two bonded systems were studied: T300/5208 graphite/epoxy adherends bonded with adhesives EC 3445 and with FM-300. For each bonded system, two specimen geometries were tested: (1) a strap adherend of 16 plies bonded to a lap adherend of 8 plies, and (2) a strap adherend of 8 plies bonded to a lap adherend of 16 plies. In all specimens tested, the fatigue failure was in the form of cyclic debonding with some 0 deg fiber pull-off from the strap adherend. The debond always grew in the region of adhesive that had the highest mode I (peel) loading and that region was close to the adhesive-strap interface. Furthermore, the measured cyclic debond growth rates correlated well with total strain energy release rates G(T) as well as with its components G(I) (peel) and G(II) (shear) for the mixed-mode loading in the present study.
    Keywords: COMPOSITE MATERIALS
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    Publication Date: 2011-08-19
    Description: A wave sensor, consisting of parallel, evenly spaced capacitance wires, whose output is the sum of the water surface deflections at the wires, has been built and tested in a wave tank. The probe output simulates Bragg scattering of electromagnetic waves from a water surface with waves; it can be used to simulate electromagnetic probing of the sea surface by radar. The study establishes that the wave probe, called the 'Harp' for short, will simulate Bragg scattering and that it can also be used to study nonlinear wave processes.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Atmospheric and Oceanic Technology (ISSN 0739-0572); 1; 358-371
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    Publication Date: 2011-08-19
    Description: The standard balloon-borne radiosonde employed for synoptic meteorology provides vertical profiles of temperature, pressure, and humidity as a function of elapsed time. These parameters are used in the hypsometric equation to calculate the geopotential altitude at each sampling point during the balloon's flight. It is important that the vertical location information be accurate. The present investigation was conducted with the objective to evaluate the altitude determination accuracy of the standard radiosonde throughout the entire balloon profile. The tests included two other commercially available pressure sensors to see if they could provide improved accuracy in the stratosphere. The pressure-measuring performance of standard baroswitches, premium baroswitches, and hypsometers in balloon-borne sondes was correlated with tracking radars. It was found that the standard and premium baroswitches perform well up to about 25 km altitude, while hypsometers provide more reliable data above 25 km.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Journal of Atmospheric and Oceanic Technology (ISSN 0739-0572); 1; 321-327
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2011-08-19
    Description: A novel class of addition-type polyimides has been developed in response to the need for high temperature polymers with improved processability. The new plastic materials are known as PMR (for in situ polymerization of monomer reactants) polyimides. The highly processable PMR polyimides have made it possible to realize much of the potential of high temperature resistant polymers. Monomer reactant combinations for several PMR polyimides have been identified. The present investigation is concerned with a review of the current status of PMR polyimides. Attention is given to details of PMR polyimide chemistry, the processing of composites and their properties, and aerospace applications of PMR-15 polyimide composites.
    Keywords: COMPOSITE MATERIALS
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Publication Date: 2011-08-19
    Description: This paper presents an algorithm for azimuth correlation of synthetic aperture radar (SAR) data with extraordinarily large-range migration which cannot be accommodated by the existing frequency domain interpolation approach used in current Seasat SAR processing. A mathematical model is provided for the SAR range-correlated point-target response both in the spatial and frequency domains. A simple and efficient processing algorithm derived from the exact two-dimensional correlation algorithm is given. This algorithm enables azimuth correlation by two cascaded one-dimensional correlation steps. The first step is to transform the range-correlated SAR data into the frequency domain in azimuth, followed by a newly developed range convolution filter to correct the range-dispersed spectrum of the range-correlated point-target response (RCPTR). The second step is the frequency-domain range migration correction approach for the azimuth compression. Simulation results provided here indicate that this processing algorithm yields a satisfactory compressed impulse response for SAR data with large-range migration whereas previous methods were subject to a broadening of the impulse response along range.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: IEEE Transactions on Geoscience and Remote Sensing (ISSN 0196-2892); GE-22; 592-597
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    Publication Date: 2011-08-18
    Description: A new two-wavelength lidar technique for remotely measuring the pressure profile using the trough absorption region between two strong lines in the oxygen A band is described. The theory of integrated vertical path, differential ranging, and horizontal-path pressure measurements is given, with methods to desensitize and correct for temperature effects. The properties of absorption troughs are described and shown to reduce errors due to laser frequency jitter by up to two orders of magnitude. A general analysis, including laser bandwidth effects, demonstrates that pressure measurements with an integrated-vertical-path technique are typically fifty times more accurate than with a differential ranging technique. Simulations show 0.1-0.3 percent accuracy for ground and Shuttle-based pressure-profile and surface-pressure experiments.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 22; 3759-377
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    Publication Date: 2011-08-18
    Description: A convenient procedure is described to determine the hygral behavior (moisture expansion coefficients and moisture stresses) of angleplied fiber composites using a pocket calculator. The procedure consists of equations and appropriate graphs for various (+ or - theta) ply combinations. These graphs present reduced stiffness and moisture expansion coefficients as functions of (+ or - theta) in order to simplify and expedite the use of the equations. The procedure is applicable to all types of balanced, symmetric fiber composites including interply and intraply hybrids. The versatility and generality of the procedure is illustrated using several step-by-step numerical examples. Previously announced in STAR as N82-16181
    Keywords: COMPOSITE MATERIALS
    Type: SAMPE Quarterly (ISSN 0036-0821); 14; 30-39
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Publication Date: 2011-08-18
    Description: It is found that the mechanical properties of fibrous refractory composite insulation (FRCI) can be improved if a higher calcination temperature is used before final processing. The results also reveal that a higher density FRCI containing 60 wt pct aluminoborosilicate fibers will exhibit minimal surface recession at 1480 C in a convective-heating environment. Another finding is that the material performance in the convective-heating environment is limited by the coating and the temperature capability of its emittance agent. A table is included giving the coating compositions used with the composite insulation and tested in the convectively heated environment at a surface temperature of 1480 C.
    Keywords: COMPOSITE MATERIALS
    Type: Ceramic Engineering and Science Proceedings (ISSN 0196-6219); 4; 551-563
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    Publication Date: 2011-08-18
    Description: The laser-induced fluorescence (LIF) of green plants was evaluated as a means of remotely detecting plant stress and determining plant type. Corn and soybeans were used as representatives of monocots and dicots, respectively, in these studies. The fluorescence spectra of several plant pigments was excited with a nitrogen laser emitting at 337 nm. Intact leaves from corn and soybeans also fluoresced using the nitrogen laser. The two plant species exhibited fluorescence spectra which had three maxima in common at 440, 690, and 740 nm. However, the relative intensities of these maxima were distinctly different for the two species. Soybeans had an additional slight maxima at 525 nm. Potassium deficiency in corn caused an increase in fluorescence at 690 and 740 nm. Simulated water stress in soybeans resulted in increased fluorescence at 440, 525, 690, and 740 nm. The inhibition of photosynthesis in soybeans by 3-(3-4-dichlorophenyl)-1-1-dimethyl urea (DCMU) gave incresed fluorescence primarily at 690 and 740 nm. Chlorosis as occurring in senescent soybean leaves caused a decrease in fluorescence at 690 and 740 nm. These studies indicate that LIF measurements of plants offer the potential for remotely detecting certain types of stress condition and also for differentiating plant species.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 134-142
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    Publication Date: 2011-08-18
    Description: Airborne laser-induced, depth-resolved water Raman backscatter is useful in the detection and mapping of water optical transmission variations. This test, together with other field experiments, has identified the need for additional field experiments to resolve the degree of the contribution to the depth-resolved, Raman-backscattered signal waveform that is due to (1) sea surface height or elevation probability density; (2) off-nadir laser beam angle relative to the mean sea surface; and (3) the Gelbstoff fluorescence background, and the analytical techniques required to remove it. When converted to along-track profiles, the waveforms obtained reveal cells of a decreased Raman backscatter superimposed on an overall trend of monotonically decreasing water column optical transmission.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 22; 3778-378
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...