ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Artikel  (4)
  • mice  (4)
  • Wiley-Blackwell  (4)
  • Copernicus
  • National Academy of Sciences
  • 2010-2014
  • 1980-1984  (4)
  • 1945-1949
  • 1925-1929
  • 1983  (4)
  • Physik  (4)
Sammlung
  • Artikel  (4)
Verlag/Herausgeber
  • Wiley-Blackwell  (4)
  • Copernicus
  • National Academy of Sciences
Erscheinungszeitraum
  • 2010-2014
  • 1980-1984  (4)
  • 1945-1949
  • 1925-1929
Jahr
Thema
  • 1
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 4 (1983), S. 267-279 
    ISSN: 0197-8462
    Schlagwort(e): mice ; specific absorption rate ; calorimetry ; TEM chamber ; 200-400 MHz CW ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Biologie , Physik
    Notizen: A maximum of six live mice, mouse cadavers, prolate spheroids molded from muscle-equivalent tissue, or saline-filled culture flasks, were exposed to continuous wave radiation in a TEM cell at frequencies between 200 and 400 MHz. Whole-body average specific absorption rate (SAR) was determined from power meter measurements of incident, reflected, and transmitted powers. The SARs for both live mice and cadavers were approximately twice that for the prolate spheroid models, and when housed in Plexiglas restraining cages, about 2 1/2 times greater. An error multiplying factor is identified, that quantitatively expresses how SAR data obtained by the three -power-meter method becomes progressively more noisy as the irradiation frequency is lowered or as the TEM cell cross section is increased.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 4 (1983), S. 371-381 
    ISSN: 0197-8462
    Schlagwort(e): 2,450 MHz ; microwaves ; natural killer cells ; macrophages ; mice ; lymphocytes ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Biologie , Physik
    Notizen: The effect of 2,450-MHz CW microwaves on natural killer (NK) cell activity and lymphocyte responsiveness to mitogen stimulation was studied in mice. Groups of mice were irradiated at power densities of 5, 15, or 30 mW/cm2 (SAR = 3.5, 10.5, and 21 W/kg respectively) for 1.5 h on 2 or 9 consecutive days. NK cell activity was determined using an in vitro 51Cr release cytotoxicity assay and an in vivo tumor-cell clearance assay. No consistent change was observed in the mitogen response of spleen cells from sham compared with irradiated mice. A significant suppression of NK cell activity measured in vitro was observed for mice irradiated at 30 mW/cm2, but not at 15 or 5 mW/cm2. A significant suppression of NK cell activity, as determined using the in vivo tumor clearance assay, was also observed at 30 mW/cm2. NK cell activity, as determined using the in vitro assay, returned to normal within 24 h following the last irradiation. Treatment of mice with hydrocortisone caused suppression of NK cell activity measured in vitro and in vivo. Paradoxically, peritoneal macrophage phagocytosis was enhanced following irradiation at 30 mW/cm2, the power density at which NK activity was suppressed. The possible role that microwave heating plays in producing these effects is discussed.
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 4 (1983), S. 383-396 
    ISSN: 0197-8462
    Schlagwort(e): hematology ; immunology ; mice ; pulsed microwaves ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Biologie , Physik
    Notizen: Mice were exposed in the far field in an anechoic chamber to 2,880-MHz pulsed microwaves 3 to 7.5 h daily, 5 days/week for 60 to 360 h. Three experiments were performed at average power densities of 5 mW/cm2 and six at 10 mW/cm2, corresponding to averaged specific absorption rates (SARs) of 2.25 and 4.50 mW/g, respectively. Each experiment consisted of eight mice, with a concurrently sham-exposed group of eight. In two of three studies at 5 mW/cm2, there was a significant increase in bone marrow cellularity in the microwave-exposed groups compared to the sham-exposed groups. Significant differences were occasionally seen in erythrocyte, leukocyte, and platelet values from microwaveexposed groups, but were not consistently observed. In one of six groups exposed at 10 mW/cm2, mean bone marrow cellularity was reduced significantly in the microwaveexposed mice; in another group, the lymphocyte count was increased. In only one exposure (10 mW/cm2 for 360 h) was any significant effect noted on serum proteins: a reduction to 5.1 ± 0.3 g/dl in the exposed versus 5.6 ± 0.4 g/dl in the sham-exposed mice. This was due to a decrease in alpha and beta globulins, with no effect on albumin or gamma globulin concentrations. No effect on bone marrow granulocyte/macrophage colony-forming units (CFU) was revealed following exposure of mice to pulsed microwaves at 5 mW/cm2. In one of four exposures at 10 mW/cm2, there was a significant increase in CFU-agar colonies. No significant effects of exposures at 10 mW/cm2 were observed on in vivo and in vitro assays of cell-mediated immune functions. No exposure-related histopathologic lesions were found from examination of several tissues and organs. Results of these series of exposures of mice at SARs of 2.25 and 4.50 mW/g indicated no consistent effects on the hematologic, immunologic, or histopathologic variables examined.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 4 (1983), S. 181-191 
    ISSN: 0197-8462
    Schlagwort(e): 60-Hz electric fields ; arousal response ; electric field strength ; mice ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Biologie , Physik
    Notizen: White-footed mice, Peromyscus leucopus, were exposed to 60-Hz electric fields to study the relationship between field strength and three measures of the transient arousal response previously reported to occur with exposures at 100 kV/m. Five groups of 12 mice each were given a series of four 1-h exposures, separated by an hour, with each group exposed at one of the following field strengths: 75, 50, 35, 25, and 10 kV/m; 8 additional mice were sham-exposed with no voltage applied to the field generator. All mice were experimentally naive before the start of the experiment, and all exposures occurred during the inactive (lights-on) phase of the circadian cycle. The first exposure produced immediate increases in arousal measures, but subsequent exposures had no significant effect on any measure. These arousal responses were defined by significant increases of gross motor activity, carbon dioxide production, and oxygen consumption, and were frequently recorded with field strengths of 50 kV/m or higher. Significant arousal responses rarely occurred with exposures at lower field strengths. Responses of mice exposed at 75 and 50 kV/m were similar to previously described transient arousal responses in mice exposed to 100-kV/m electric fields. Less than half of the mice in each of the field strength groups below 50 kV/m showed arousal responses based on Z (standard) scores, but the arousals of the mice that did respond were similar to those of mice exposed at higher field strengths. Polynomial regression was used to calculate the field strength producing the greatest increases for each of the arousal measures. The results show that the amplitude of the transient arousal response is related to the strength of the electric field, but different measures of arousal may have different relationships to field strength.
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...