ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles  (139)
  • Chemistry  (139)
  • Wiley-Blackwell  (139)
  • Annual Reviews
  • Elsevier
  • Institute of Physics
  • National Academy of Sciences
  • Periodicals Archive Online (PAO)
  • Springer Nature
  • 2020-2024
  • 1985-1989
  • 1980-1984  (139)
  • 1975-1979
  • 1970-1974
  • 1955-1959
  • 1940-1944
  • 1983  (139)
  • Medicine  (139)
  • Sociology
  • Mathematics
  • Computer Science
  • Energy, Environment Protection, Nuclear Power Engineering
Collection
  • Articles  (139)
Publisher
Years
  • 2020-2024
  • 1985-1989
  • 1980-1984  (139)
  • 1975-1979
  • 1970-1974
  • +
Year
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983) 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 37-43 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The degree of microleakage between a restoration and the cavity wall is difficult to quantify objectively. A silver-staining method is used and compared to the radioisotope method with results that indicate a superior definition and more accurate evaluation of microleakage. In addition to the accuracy, two advantages are presented: (1) scoring of the leakage can be refined and divided into more precise numbers, and (2) teeth can be observed directly in a microscope without resorting to the indirect interpretation of film or photograph.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 59-70 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Porous high-density polyethylene specimens were implanted in the femurs of mongrel canines. At the end of the residency period (3 or 6 months), the animals were sacrificed and the implants were retrieved. The work-of-fracture of the implant specimens was then determined using the technique of Tattersall and Tappin. The work required to fracture a specimen in three-point bending by controlled crack propagation through a triangular cross section was obtained directly from the load-deflection curve. The area of the resulting fracture surface was measured by macro-photographic techniques, and the work-of-fracture was calculated as work per unit area. The implants were subsequently sectioned and examined microradiographically to determine the extent of bone ingrowth. Bone specimens adjacent to the implants and porous high-density polyethylene controls (no ingrowth) were also tested to determine their work-of-fracture. The results showed that bone adjacent to the implant specimens had a higher work-of-fracture than normal medial, canine femoral bone and was not appreciably different from the composite. The work-of-fracture of porous high-density polyethylene was not significantly increased by an increase in bone infiltration, and this anomalous behavior was attributed to a degradation of the polyethylene during implant residence. Control studies supported this hypothesis.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Removal of bilirubin by hemoperfusion with ion exchange resin particles is suggested to replace exchange transfusion of blood of jaundiced infants in some cases of unconjugated hyperbilirubinemia. The hemoperfusion system developed here consists of a packed bed of a macroreticular resin which is made biocompatible by a coating of a monomolecular layer of albumin. The choice of the appropriate ionic form of the resin and the proper albumin coating and crosslinking procedure assures a high bilirubin adsorption capacity and excellent blood compatibility of the resin. The albumin coated resin removes in vitro 80-90% of the bilirubin initially present in the plasma. The results encourage in vivo clinical studies.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Double catheter systems consisting of a stiff outer catheter and a flexible, buoyant, flow-directed, inner catheter which is often balloon-tipped have been employed with increasing frequency recently in both therapeutic and diagnostic procedures. Their use, however, has been restricted because of the excessive friction generated between the two catheters. In an attempt to decrease friction between polymers commonly used as catheter materials, oxidation of polyethylene, fluorinated ethylene-propylene copolymer, poly(vinyl chloride), silicone rubber, and polystyrene surfaces was induced by exposing the polymers to radio frequency glow discharge (RFGD) in a helium environment. All polymers were surface characterized utilizing x-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and contact angle measurements before and after oxidation. This article describes the materials and methods used to fabricate and characterize the polymer surfaces and the results of the characterization. The results indicate that increases in oxygen concentration at the surface of the polymers and decreases in air-water contact angles occur with increased RFGD exposure time. Plateau values were usually obtained after 5-30 s exposure time, yet no apparent changes in surface topography were noted by scanning electron microscopy. The hydrophilic surfaces produced were stable for up to three months storage time in air.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 249-260 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The new composite concept of microfilled composites has certain advantages, such as polishability, permanent smoothness, and high abrasion resistance. In the mouth, however, these new materials are not perfect and they often fail in stress-bearing restorations. In the present study, the weak links and imperfections of these materials are determined by means of direct and indirect SEM techniques. The chemical adhesion between polymer blocks and polymer matrix is questionable; fractures occur most often at the filler-matrix interface. In vivo, there is still a certain preferential wear of the resin matrix. In Estic Microfill, rear weak zones with starlike condensations are observed, which could be related to a certain incompatibility of its composing resins and/or to incomplete and inhomogeneous polymerization. In a fractured Isopast restoration, the polymer blocks are clearly revealed, scattered in a three-dimensional polymerized matrix network.
    Additional Material: 18 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 205-227 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Ion beam etching has provided a system which can produce a controllable surface morphology in the micron range without altering surface chemistry or surface energy. PTFE (polytetrafluoroethylene) develops a surface texture having conical projections with average dimensions: height = 12 μm, base width = 4 μm, tip radius = 0.1 μm. Smooth and textured PTFE disks (1 cm diam. × 250 μm thick) were implanted subcutaneously into the dorsum of Sprague-Dawley rats for time periods of 1 and 3 days and 1,2,3,4, and 8 weeks. Smooth control samples consisted of untreated surfaces and surfaces that were exposed to an ion beam environment producing a smooth surface. All smooth surfaces behaved identically by both histochemical and histological methods. Consequently, the ion beam environment had no effect on the soft tissue response. Textured surfaces, however, demonstrated increased cell adhesion and increased succinic dehydrogenase and acid phosphatase staining in the interfacial cells. Interfacial cells consisted of foreign body giant cells and macrophages. These macrophages possessed increases in the cytoplasmic-to-nuclear ratio, number and interdigitation of filopodia, and vacuolization as demonstrated by TEM. The textured surfaces also influence the kinetics of fibrous capsule formation. At 8 weeks, capsules associated with textured interfaces were reduced in thickness by 30% when compared to smooth surfaces. The results of this investigation demonstrate that the surface texture of an implant is a critical variable in determining the soft tissue response to a material.
    Additional Material: 20 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 359-373 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Some physical, chemical, and biological characteristics of a heparin-PVA hydrogel potentially useful as a thromboresistant coating for the preparation of small-diameter vascular prostheses and blood-sampling catheters have been determined. The molecular weight between crosslinks in the acetal crosslinked gel was approximately 8000, permitting proteins the size of albumin to enter the interior of the gel. The release rate of heparin from a gel containing 7 mg/g gel was 10-2 μg/g min which was significantly lower than the reported minimum required for thromboresistance of ionically heparinized materials. Nevertheless, in vitro biological activity was observed in both thrombin time and plasma recalcification time assays, which could not be attributed to the release of heparin into the incubated plasma. Correlation of final heparin contents with the amount of terminal amino acid residues in three samples of heparin suggests that the heparin is bound to the PVA in the gel through the amino acid terminus; this provides a plausible explanation for the retention of biological activity by the immobilized heparin.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 389-391 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 17 (1983), S. 395-410 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The flexural strength, microstructure and relative Ca and Si concentration at the surface of two commercial orthopedic aluminas were studied before and after aging up to 52 weeks in simulated body fluids or in subcutaneous implantation in rodents. There was no significant reduction in flexural strength after aging, but there was evidence of Ca and Si dissolution from the external grain boundary surfaces, particularly for specimens aged in demineralized water. No change occurred in the Ca and Si concentrations within the specimen's bulk during either in vivo or in vitro aging.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...