    Journal of High Resolution Chromatography 1 (1978), S. 92-92 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Plugs for static coating procedure ; Advantages over sodium silicate setting plugs ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 93-94 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Static coating, apolar gums ; Pentane better than methylene chloride, ready in 8 hours ; (20 m, 0.3 mm i.d.) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 94-95 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Quantitative analysis of unsaturated fatty methyl esters ; Remarkable systematic errors of cis/trans determination ; Errors depend on phases chosen ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 98-99 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Quantitative analysis of higher alcohols ; Direct injection of beverages, liqueurs etc ; Inner standard dioxan, inlet modification ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 103-104 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Fittings, remaining elastic till 300°C ; Important details of proper handling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 139-142 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Hydrocarbon cut, optimized separation ; Capillary preparation for ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Techniques have been developed for the rapid separation (about 20 minutes) of the 39 compounds in crude petroleums, or petroleum distillates, which boil between 28 and 114°C. A 300 meter glass column (0.25 mm i.d.) which is etched, coated with a mixture of normal hexadecane and Kel-F10157 is utilized to perform this separation at room temperature. The separations obtained with this non-polar liquid mixture and the «inert» glass surface are much more rapid than those previously obtained with stainless steel capillary columns.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 149-155 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Preparation of apolar columns ; Ba CO3 procedure optimized for thermostability acid/base behaviour and efficiency ; New, quantitative testing procedure ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: As an extension of previous reports, the barium carbonate procedure has been optimized in detail for the preparation of apolar columns. The aim was to produce optimum overall column characteristics, and to maintain them unchanged under the prolonged influence of the highest possible temperature. The main parameters under optimization were glass variety, leaching of glass surface with aqueous HCl, and amount of barium carbonate deposited, while deactivation and coating were kept constant. The basic column characteristics were adsorption properties and thermostability of deactivation, acid/base behaviour and separation efficiency. They were determined by a new, quantitative testing procedure. Intense leaching was able to eliminate almost totally the differences between glass varieties and to create a well-defined glass surface. While untreated glass, leached glass, and barium carbonate treated glass showed specific weak points in the respective column quality, the combination of leaching and barium carbonate treatment yielded the highest and most stable quality. Some technical modifications of the preparation procedure are described, including deactivation in the gas phase, and use of pentane as a solvent for static coating.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 13-17 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Low dead volume effluent splitters preparation of Heartcutting ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Practical details are given to produce low dead volume Pt/Ir to glass connections and a variety of components for effluent splitting and pneumatic solute switching. It is shown that the column effluents from a glass capillary column can be split in any desired ratio and maintained constant, regardless of column flow rate. Bandbroadening in the splitter remains negligible even for very low flow rates. A complex pneumatic system to be used for heartcutting with two glass capillary columns is shown.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 28-33 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Surface roughening by whiskers ; Advantages (any phase…) ; Disadvantages (activity…) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Growing whiskers on the inner wall of glass capillary columns is an easy roughening technique which allows efficient coating of the columns with any stationary phase. The advantages and disadvantages of whisker surfaces are discussed. Several examples are presented to illustrate the possibilities of whisker-wall coated open tubular (WWCOT) columns.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 21-27 
    ISSN: 0935-6304
    Keywords: Liquid Chromatography ; Capillary, glass ; Preparation of LC-Capillaries ; Investigation of column parameters ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Micro capillary columns were successfully applied to liquid chromatography by employing the principles used in micro high performance liquid chromatography. Fundamental investigations on the use of capillary columns in LC were performed for the various column parameters. Good separations of five aromatic hydrocarbons and four kinds of phthalic esters were obtained on a 62 μm I.D. capillary column, coated with SE-30.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 47-53 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Separation of fatty acid benzyl esters ; Benzylation ; Response factor irregularities ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Volatile fatty acids in aqueous media were esterfied in situ with phenyldiazomethane (PDM). Complete esterification was achieved in 3 h at 40°C under continuous stirring of an ether/water system. The process involved immediate transfer of benzyl esters into the organic phase. The separation of benzyl esters mixtures was carried out in glass capillary GC columns. The retention data and FID molar responses were determined for C1 to C6 acid benzyl esters, including 2-methylpropionic, 3-methylbutyric, 2-methylvaleric, and 2-ethylbutyric acid. An unusual relationship was observed between benzyl ester relative molar responses and carbon atom number.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 54-56 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Separation and quantitation of bile acid TMS esters ; On - column injection technique ; (quantitative investigation of) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Analysis of trimethylsilylethers of methyl esters of bile acids exhibits high separation efficiency with a 20 m × 0.3 mm glass capillary column covered with a crystal layer of barium carbonate and coated with polyethyleneglycol 20000 as liquid phase [3]. The sensitivity and reproducibility of this method can be further improved by an on-column injection technique according to Grob et al. [4].
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 174-176 
    ISSN: 0935-6304
    Keywords: Liquid Chromatography ; Capillary, glass ; Tight coiling not beneficial, column wall modifications ; Future lies in extreme miniaturization ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Some experimental results of LC in capillary columns are presented. The possible effect of turbulence which has been much emphasised lately is overrated. The future of LC in capillary columns lies in extreme miniaturization.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Femtogram trace analysis of halogenated hydrocarbons in water ; Sea-, tap-, waste water ; Extraction procedure ; Direct water sample injection ; Selection of glass capillaries ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A rapid and sensitive method to determine volatile organohalides in different types of waters has been developed. The chromatographic system is based on the resolving power of the glass capillary column and the high sensitivity of the electron capture detector. The capillary columns were connected to the detector so that the eluate from the column is mixed with thermostatted purge gas to minimize band broadening due to dead volumes. The low column bleeding and decreased band spreading from capillary columns enhance the sensitivity to very low levels: 1 fg (10-15g) for carbon tetrachloride, despite dilution of the column eluate by the purge gas.The water samples of 100 ml were extracted with 1 to 10 ml n-pentane which is the most practical alkane with respect to purity. When using high water to pentane ratios corrections had to be made, due to low extraction yield, to get accurate quantifications.A column with Carbowax 400 stationary phase permits direct tap water injection. The water peak concealed the substances eluated after CHCl3 and CHBrCl2.The gas chromatographic separation of haloforms in tap water could be shortened to 30 seconds using a 10 m SE-52 column with an increased film thickness.Besides tap water and seawater, industrial waste water from a pulp mill was analyzed. Ten different halogenated organic compounds, ranging from 1 ng/I to 760 μg/I, were quantified in the different waters. Bromoform, which had not previously been found in seawater, was detected.Chromatogram of a standard mixture containing 11 organohalides. Stationary phase, SE-52; 33 m × 0.3 mm i.d. inj. temp. 200°, column temp. 50°, interface 250°, detector temp. 250°. Helium carrier gas flow rate, 36 cm/s, scavenger'gas flow 30 ml/min.Split ratio 1:20, 1 = CH2CI2, 2 = CHC13, 3 = CH3CC13, 4 = CC14, 5 = CHCICCI2, 6 = CHBrCI2, 7 = CBrC13, 8 = CHBr2Cl, 9 = CCl2CC12, 10 = CHCl2l, 11 = CHBr3.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 57-64 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Splitless injection, basis of ; Use for any sample ; Optimization ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Splitless injection is based on the solvent effect as a mechanism condensing large vapour clouds down to infinitely shortened bands. The effect is controlled by the parameters column temperature, volatility and amount of solvent, and rate of injection. By properly selecting the variables the effect can easily be optimized for any combination of sample and column. It is the purpose of this paper to provide the mechanistic understanding as required for this optimization, as well as some rules for the experimental realization. Potentialities and limitations of splitless injection are discussed, and the role of the solvent effect in on-column injection is emphasized.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 71-72 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Separation of the four 10,12-Hexadecadiene-1-ol isomers ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Complete gas-liquid chromatographic separation of the four 10, 12-hexadecadiene-l-ol isomers using a FFAPcoated glass capillary column is described.These measurements are of importance for the analysis of pheromones from biological sources and for the control of material from stereospecific syntheses.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 109-110 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Computer reconstruction of chromatograms without distortion of peak shape ; Vertical/horizontal scaling to almost any paper size ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This paper describes two programs that are used to plot digital area slice data from glass capillary gas chromatograms. The programs are written in H/P LAB BASIC II, and can be executed on Hewlett-Packard 3354A Laboratory Data Systems using digital plotting devices. The programs are designed to plot high resolution chromatograms, allow horizontal and vertical scaling, and the plots can be numbered and labelled.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 302-303 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Testing uncoated columns ; Test with precolumn ; Adsorption, and acid/base effects ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 221-222 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Solution of liquid phase ; Stored solutions produce less thermostable columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 277-278 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Static coating technique for columns up to 50 m ; Degassing solvents, closing procedure ; Extraordinary requirements for water bath ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 279-280 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Static coating technique ; A standard procedure, 7 critical points ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 211-212 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Subambient temperatures ; Cryogenic unit, inexpensive ; Temp. programming from ca. -50°C ; Automobile exhaust analysis, improved separation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 263-267 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; On-column injection ; Recommendations for users ; Sample size 0.1-8.0 μl ; Optimization ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: During one year continuous use of on-column injection, the typical advantages described in our first report have fully been confirmed. In addition the analysis of large sample volumes has proved promising. Only minor modifications have been applied to the on-column injector device. Broad evidence has been gathered showing that full separation efficiency of the capillary columns after on-column injection is attained only when cold trapping or the solvent effect, as band shortening mechanisms, are working- While, under the conditions of on-column injection, cold trapping is less efficient than with other injection techniques, the opposite holds true for the solvent effect. Compared with splitless injection, the danger of excessive solvent condensation on the column is increased. A working rule is presented for establishing the optimal chromatographic conditions for handling large sample volumes while ensuring full separation efficiency yet avoiding harm to the column.
    Additional Material: 5 Ill.