ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Chromatographie, Dünnschicht  (138)
  • Spektralphotometrie, Atomabsorption  (122)
  • Springer  (260)
  • MDPI Publishing
  • Springer Science + Business Media
  • 1975-1979  (180)
  • 1970-1974  (80)
Collection
Keywords
Publisher
  • Springer  (260)
  • MDPI Publishing
  • Springer Science + Business Media
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 294 (1979), S. 287-287 
    ISSN: 1618-2650
    Keywords: Nachw. von Carbamatpesticiden in biolog. Material ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 294 (1979), S. 345-351 
    ISSN: 1618-2650
    Keywords: Best. von Wismut, Cadmium, Thallium in Gesteinen ; Spektralphotometrie, Atomabsorption ; fraktionierte Destillation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The analysis of bismuth, cadmium and thallium in rock samples can be performed by flameless atomic absorption spectrometry, after separation and preconcentration by a volatilization technique. This method has the major advantage that small amounts of substance can be used with a minimum consumption of chemicals, so that sources of contamination are reduced. The detection limit for Bi and Tl is about 1 ppb and for Cd about 0.1 ppb in the rock. Depending on the content in the rock samples, the relative standard deviation is between 2 and 30%. Several attempts have been made to determine the yields of Bi, Cd and Tl from synthetic and natural samples.
    Notes: Zusammenfassung Die Bestimmung von Wismut, Cadmium und Thallium in Gesteinen kann mit der flammenlosen Atomabsorptions-Spektroskopie nach verdampfungsanalytischer Abtrennung erfolgen. Die Verdampfungsnalyse hat den Vorteil, daß bei geringem Reagentienverbrauch kleine Mengen analysiert werden können. Die Gefahr der Einschleppung von Verunreinigungen wird erheblich vermindert. Die Nachweisgrenze bezogen auf die Probe beträgt für Wismut und Thallium ca. 1 ppb und für Cadmium ca. 0.1 ppb. In Abhängigkeit von der Konzentration liegt die relative Standardabweichung zwischen 2 und 30 %. An synthetischen und natürlichen Proben sind die Ausbeuten an diesen Elementen bestimmt worden.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 294 (1979), S. 361-365 
    ISSN: 1618-2650
    Keywords: Chromatographie, Dünnschicht ; Informationsgehalt und »Äquivokation«
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A method has been developed for the calculation of information contents of one-channel identification procedures, which is especially applicable in the area of thin-layer chromatography (TLC). The method can be considered as a refinement of the one proposed by Massart and can easily be extended to the combination of one-channel procedures. In addition, the quantity ‘equivocation’, which is complementary to the information content, is introduced. As an example the best TLC-systems and the best combinations of two TLC-systems for the identification of DDT and twelve related compounds are selected by using information contents or equivocations. The results for the individual systems are compared with those obtained by Massart.
    Notes: Zusammenfassung Eine Methode zur Berechnung von Informationsgehalten von Einkanal-Identifizierungsverfahren wurde entwickelt, die besonders gut für das Gebiet der Dünnschicht-Chromatographie (DC) anwendbar ist. Sie kann als eine Verfeinerung der von Massart vorgeschlagenen Methode angesehen werden und kann auf einfache Weise für Kombinationen von Einkanal-Verfahren erweitert werden. Dabei wird der Begriff »Äquivokation«, komplementär zum Informationsgehalt, eingeführt. Als Beispiel wurden die besten DC-Systeme und Kombinationen von zwei DC-Systemen für die Identifizierung von DDT und zwölf verwandten Verbindungen unter Benutzung von Informationsgehalten oder »Äquivokationen« ausgewählt. Die Ergebnisse für die einzelnen Systeme werden mit den nach Massart gefundenen verglichen.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 294 (1979), S. 407-407 
    ISSN: 1618-2650
    Keywords: Trenn. von Arylbenzolsulfonylthiocarbamiden ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 295 (1979), S. 355-361 
    ISSN: 1618-2650
    Keywords: Best. von Blei in Geolog. Material, Biolog. Material ; Spektralphotometrie, Atomabsorption ; Graphitrohrküvette
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Serious systematic errors inherent in the determination of lead in geological and biological samples by flameless atomic-absorption spectrometry are demonstrated. The reduced absorption of lead is due to partial interaction with alkaline, alkaline-earth and iron chlorides during the atomization stage. Incomplete dissociation of the volatile monochloride of lead in the gaseous phase reduces the absorption signal. An addition of 20% hydrogen to nitrogen (purge gas) diminishes signal suppression by removing the chlorine in form of volatile HCl. The detection limit is about 0.6 ppm in rocks and about 0.3 ppm in plant materials. Depending on the content in the samples the relative standard deviation is between 1 and 12%. The accuracy of the method was tested on 39 international standard reference samples.
    Notes: Zusammenfassung Schwerwiegende systematische Fehler bei der Bestimmung von Blei in geologischen und biologischen Materialien mit der Graphitrohrküvette werden aufgezeigt. Die Reaktion von Blei mit Alkali-, Erdalkali- und Eisenchloriden während der Atomisierungsphase führt zur Bildung von Bleimonochlorid, das nur unvollständig dissoziiert und eine Signalunterdrückung zur Folge hat. Ein Zusatz von 20% Wasserstoff zu Stickstoff als Spülgas vermindert die Signalunterdrückung, indem überschüssiges Chlor als Chlorwasserstoff entfernt wird. Die Nachweisgrenze liegt bei ca. 0,6 ppm für Gesteine und bei ca. 0,3 ppm für Pflanzenmaterialien. Je nach der Konzentration beträgt die relative Standardabweichung 1–12%. Die Genauigkeit der Methode wurde an 39 internationalen Standardreferenzproben überprüft.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 295 (1979), S. 398-401 
    ISSN: 1618-2650
    Keywords: Analyse von pharmazeut. Produkten ; Chromatographie, Dünnschicht ; halogenfreie Fließmittelsysteme
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Mit 2 sauren, 2 basischen und einem neutralen Fließmittel mit unterschiedlichen Polaritäten und guten Trennleistungen konnten 151 von 157 geprüften Arzneisubstanzen mit hRf-Werten zwischen 10 und 90 chromatographiert werden.
    Notes: Summary Using two acidic, two alkaline and a neutral mobile phase of different polarities and high separation efficiencies 151 of 157 tested drug substances could be chromatographed with hRf-values between 10 and 90.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 294 (1979), S. 402-404 
    ISSN: 1618-2650
    Keywords: Best. von Antimon in Biolog. Material ; Spektralphotometrie, Atomabsorption ; Nanospuren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Eine selektive Bestimmung von Antimon durch Atomabsorptionsspektrometrie ist durch elektrothermale Atomisierung von Antimonwasserstoff in einem Argonspülgasstrom möglich. Das Verfahren erfordert eine hohe und reproduzierbare Geschwindigkeit der Reduktion des Antimons zu Antimonwasserstoff in der wäßrigen Probelösung. Geeignete Bedingungen für diese Reduktion erreicht man, wenn man in der Lösung zunächst einen Komplex von Antimon(III) mit Äthylendiamintetraessigsäure bildet; dieser Komplex reagiert mit Natriumborhydrid in der geforderten Weise zu Antimonwasserstoff. Bei der Mineralisierung des organischen Materials ist auf genaue Temperaturführung zu achten.
    Notes: Summary High selectivity in measuring antimony by atomic absorption spectrometry is obtained by electrothermal atomisation of stibine in a stream of argon purging gas. This procedure requires a fast and reproducible reduction to stibine of the total antimony present in an aequeous solution. Optimum conditions for this reduction are reached by first transforming all antimony in the solution to an EDTA-chelate of antimony(III) which then reacts uniformly with sodium boron hydride to give stibine. Close temperature control is essential in decomposition of biological samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 294 (1979), S. 416-416 
    ISSN: 1618-2650
    Keywords: Best. von Blei in Benzin ; Spektralphotometrie, Atomabsorption ; emulgierte Proben
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 295 (1979), S. 24-29 
    ISSN: 1618-2650
    Keywords: Best. von Polycyclen in Wasser ; Chromatographie, Dünnschicht ; Änderung der Fluorescenzintensität
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Nach der Verordnung über Trinkwasser und Brauchwasser für Lebensmittelbetriebe (Trinkwasserverordnung) vom 31. Januar 1975 müssen 6 Einzelverbindungen aus der Gruppe der polycyclischen aromatischen Kohlenwasserstoffe nachgewiesen werden. Das empfohlene Analysenverfahren basiert auf der Messung der Fluorescenz nach vorangegangener chromatographischer Trennung auf Adsorberschichten. Sowohl bei dieser Trennung als auch in der anschließenden Zeit verändert sich die Fluorescenzintensität einzelner Verbindungen z.T. beträchtlich. Systematische Untersuchungen an Kieselgel und an Mischschichten aus Aluminiumoxid und Acetylcellulose sollen die kritischen Punkte und die möglichen Fehlerquoten offen legen.
    Notes: Summary According to the regulation on the use of drinking and industrial water in food industry (Drinking Water Regulation) of 31 January, 1975, six individual compounds of the group of polycyclic aromatic hydrocarbons must be traced. The analytical procedure recommended is based on the measurement of fluorescence after preceding Chromatographic separation on adsorber layers. In the course of this separation and during the time that follows, the fluorescence intensity of various compounds changes, in some cases considerably. Systematic studies with silica gel and mixed layers of aluminium oxide and acetyl cellulose are intended to reveal critical points and possible ranges of error.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 295 (1979), S. 110-115 
    ISSN: 1618-2650
    Keywords: Best. von Cadmium in Boden, Sedimenten ; Spektralphotometrie, Atomabsorption ; Zr-beschichtete Graphitrohre
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird ein Verfahren beschrieben, das es gestattet, nach einer Anreicherung von Cadmium durch Extraktion mit APDC/MIBK und anschließender Reextraktion mit Salpetersäure, die stark salpetersaueren Reextrakte direkt in Zirkonium-beschichteten Graphitrohren bei Verwenden der flammenlosen Atomabsorption zu vermessen. Diese Rohre zeigten eine gute Lebensdauer (150–300 Analysen). Durch eine Behandlung der Rohre mit einer Fe3+-Lösung konnten Beeinflussungen der Cadmiumsignale durch Begleitstoffe verhindert werden. Cadmium wird bei der Extraktion und Reextraktion um den Faktor fünf angereichert. Bei hohen Cadmiumgehalten in den Proben kann die Analyse bei gleicher Probenvorbereitung mit Hilfe der Flammenatomabsorption durchgeführt werden. Die Arbeitsbedingungen für die flammenlose, sowie für die Flammen-Atomabsorption werden angegeben. Als Nachweisgrenzen bei Verwenden der flammenlosen Atomabsorption wurden im Mittel 0,53 μg Cd/l, für die Flammenatomabsorption 19,4μg Cd/l gefunden, die durch die Anreicherung auf ca. 0,1, bzw. 4 μg Cd/l gesenkt werden.
    Notes: Summary Cadmium is enriched by an extraction with APDC/MIBK and subsequent reextraction with nitric acid. A procedure is described for analyzing these solutions directly by means of flameless atomic absorption, inspite of the high concentration of nitric acid in a zirconium coated graphite tube. These tubes, proved to be very resistant (150–300 analyses). After treatment of the tubes with a Fe3+-solution no interference by accompanying anions and cations could be observed. By the extraction and reextraction procedure described cadmium is enriched by a factor of five. Samples of higher cadmium concentrations were analyzed by means of flame atomic absorption after the same sample preparation. Working conditions for flameless and flame atomic absorption are given. Detection limits have been calculated as 0.53 μg Cd/l in the case of flameless, 19.4 μg Cd/l in the case of flame atomic absorption. These values are further decreased by the above enrichment procedure to 0.1 and 4 μg Cd/l, respectively.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 11
    ISSN: 1618-2650
    Keywords: Best. von Quecksilber, Silber, Kupfer, Wismut, Blei, Cadmium, Tellur in Wasser ; Röntgenfluorescenz-Spektrometrie ; Spektralphotometrie, Atomabsorption ; Spuren, Anreicherung an Sulfidschichten, Fällungsaustausch
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Zur Verbesserung des Nachweisvermögens und der Zuverlässigkeit von röntgenfluorimetrischen und atomabsorptiometrischen Bestimmungsverfahren für geringe Spurengehalte von Hg, Ag, Cu, Bi, Pb, Cd, Sn, As, Se, Te, Zn, Co und Ni in wäßrigen Lösungen wurde die Eignung einer der Bestimmung vorgeschalteten Anreicherungsmethode durch Fällungsaustausch an einer dünnen Sulfidschicht systematisch untersucht. Die wäßrige Probe (0,1–61, pH 3–6) wird durch eine auf einem Membranfilter (Cellulosenitrat bzw. PTFE, Porenweite ≤1 μm) frisch präparierte homogene Metallsulfidschicht (ZnS, MnS, CuS, PbS u.a., Dicke: 300–400 nm) filtriert. Dabei werden mit Ausnahme des Arsens die Elemente praktisch vollständig aus der Lösung zurückgehalten, die schwerlösliche Sulfide mit einem kleineren Löslichkeitsprodukt als das der austauschenden Schicht bilden. Nach dem Austausch kann die Bestimmung der Elemente entweder simultan durch RFA direkt auf dem Filter oder nach Lösen des Niederschlages in wenig Säure durch AAS mit elektrothermischer Atomisierung erfolgen. Durch erhebliche Voranreicherung können Nachweisgrenzen im ng/l-Bereich erzielt werden. Eichung, Störungen durch Begleitsubstanzen und Güteziffern des Verbundverfahrens werden beschrieben, das vor allem für die simultane und zuverlässige Bestimmung von Spuren, Hg, Ag, Cu, Bi, Pb, Cd und Te in Trink-, Oberflächen- und Schneeschmelzwasser empfohlen werden kann.
    Notes: Summary For the improvement of the power of detection and the reliability of X-ray fluorimetric and atomic-absorption spectrometric determination procedures for very low levels of Hg, Ag, Cu, Bi, Pb, Cd, Sn, As, Se, Te, Zn, Co and Ni in aqueous solutions the applicability of a pre-concentration method by precipitate-exchange on thin sulphide layers which preceds the actual determination has been investigated systematically. The aqueous sample (0.1–61, pH 3–6) is filtered through a freshly prepared homogeneous metal sulphide layer (e.g. ZnS, MnS, CuS, PbS, thickness: 300–400 nm) which is placed on a membrane filter (cellulose nitrate or PTFE, pore size ≤1 μm). In this way with the exception of As, the elements forming sparingly soluble sulphides with a lower solubility product than the corresponding sulphides of the layer are practically completely retained from the solution. The exchanged elements can be determined either simultaneously directly on the filter by RFA or sequentially after dissolution of the precipitate in a small volume of acid by AAS with electrothermal atomization. By a considerable pre-concentration detection limits in the ng/l range can be obtained. Calibration, interferences by concomitant elements, and quality grades of the multi-stage procedure are described, which can be recommended for the simultanous and reliable determination of traces of Hg, Ag, Cu, Bi, Pb, Cd, and Te in potable, surface, and snow-melting water.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 295 (1979), S. 352-354 
    ISSN: 1618-2650
    Keywords: Best. von Kupfer mit Zinkdibenzyldithiocarbamat ; Spektralphotometrie, Atomabsorption ; Lösungsmittel für die Extraktion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The utility of various organic solvents, such as acetates and ketones, for the CuDBC chelate extraction and subsequent atomic absorption spectrophotometric determination is studied. Methyl propionate was found to be the most sensitive solvent. Data for the different substances are presented.
    Notes: Zusammenfassung Die Verwendbarkeit verschiedener Lösungsmittel (Acetate und Ketone) für die Extraktion des CuDBC-Komplexes und anschließende atomabsorptions-spektralphotometrische Bestimmung wurde systematisch untersucht. Werte für die verschiedenen Substanzen werden angegeben. Die größte Empfindlichkeit kann mit Methylpropionat erzielt werden.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 297 (1979), S. 138-143 
    ISSN: 1618-2650
    Keywords: Trenn, der Metallchelate von 8-Mercaptochinolin ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung 8-Mercaptochinolin (Thiooxin) eignet sich zum Nachweis und zur Trennung von Metallen mit Hilfe der Dünnschicht-Chromatographie. Es bildet Neutralkomplexe definierter Zusammensetzung, die in wäßriger Phase schwerlöslich sind und in Chloroform extrahiert werden können. Fällung und Extraktion sind vom pH-Wert abhängig, wodurch eine Vortrennung der Metalle möglich ist. Beschrieben wird das dünnschicht-chromatographische Verhalten von 17 Metallchelaten. Die intensive Eigenfärbung der Komplexe erübrigt den Gebrauch von Anfärbereagentien. Die visuelle Nachweisgrenze der Metalle liegt zwischen 5 und 20 ng (Fluorescenzlöschung bei 254 nm). Spektralphotometrische Auswertung der Chromatogramme läßt eine Erniedrigung der Nachweisgrenze um etwa eine Zehnerpotenz erwarten.
    Notes: Summary 8-Mercaptoquinoline (thiooxine) is qualified for the detection and separation of metals by thin-layer chromatography. It forms neutral complexes in definite composition, which are insoluble in aqueous solution, but readily soluble in CHCl3. Precipitation and extraction are dependent on the pH value, whereby pre-separation of metals is possible. The thin-layer chromatographic behaviour of 17 metal chelates is described. No spraying is necessary for detection, since the complexes show different, characteristic colours. The visual detection limits of the metals are between 5 and 20 ng (fluorescence quenching at 254 nm). Spectrophotometric determination of the chromatograms lowers the detection limit by one power of ten.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 297 (1979), S. 144-147 
    ISSN: 1618-2650
    Keywords: Trenn. der Metallchelate von 1-Hydroxy-2-pyridinthion ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung 1-Hydroxy-2-pyridinthion (HPT) bildet mit den Metallen der 8. Nebengruppe des Periodensystems intensiv gefärbte Chelatkomplexe. Führt man die Reaktion in wäßriger Phase bei pH 7 aus, so werden alle Elemente der Gruppe erfaßt und als schwerlösliche Neutralkomplexe gefällt. Diese lassen sich mit Chloroform extrahieren und dünnschichtchromatographisch trennen. Die Nachweisgrenze der Metalle liegt zwischen 3 und 40 ng (Fluorescenzlöschung bei 254 nm). Spektralphotometrische Auswertung der Chromatogramme läßt eine Erniedrigung der Nachweisgrenze um eine Zehnerpotenz erwarten.
    Notes: Summary 1-Hydroxy-2-pyridinethione (HPT) forms highly coloured chelate complexes with the metals of the 8th sub-group. If the reaction is carried out in aqueous solution at pH 7, all elements of the group precipitate as insoluble neutral complexes. They can be extracted with CHCl3 and separated by thin-layer chromatography. The detection limit is between 3 and 40 ng (fluorescence quenching at 254 nm). Spectrophotometric determination of the chromatograms lowers the detection limit by one power of ten.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 298 (1979), S. 9-11 
    ISSN: 1618-2650
    Keywords: Best. von Quecksilber in Luft ; Spektralphotometrie, Atomabsorption ; neues Spektrometer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Ein Atomabsorptions-Spektrometer wird beschrieben, das zur Bestimmung des Quecksilbergehaltes in Luft die Absorption der im vakuumultravioletten Spektralbereich gelegenen Hg-Resonanzlinie 184,9 nm benutzt. Die Kombination einer Hg-Niederdruckdampflampe mit einer Photozelle mit CsI-Kathode gestattet einen Spektrometer-Aufbau ohne Monochromator oder Filter. Zur Messung der HgKonzentration in Gasen wird das Quecksilber einer Probe zunächst auf einem Goldblech gesammelt, durch Ausheizen des Goldes wieder freigesetzt und die Absorption durch die Dampfwolke bestimmt. Das Eichverfahren und Meßbeispiele werden erläutert.
    Notes: Summary An atomic absorption spectrometer is described using the absorption of the vacuum ultraviolet resonance line 184.9 nm to determine the amount of mercury in air. The use of a mercury low-pressure discharge lamp combined with a CsI photocell makes it possible to omit monochromator or filter. For measuring the concentration of mercury in all sorts of gases the mercury of the sample is collected on sheet gold. By heating the sheet mercury is set free and the absorption of the mercury vapour can then be measured. The calibration procedure and some analytical results are described.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 298 (1979), S. 44-44 
    ISSN: 1618-2650
    Keywords: Trenn. von Guanylpyrazolnitraten ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 125-127 
    ISSN: 1618-2650
    Keywords: Best. von Phosphor in Stahl ; Spektralphotometrie, Atomabsorption ; flammenlos, ZrC-beschichtete Graphitrohrküvette
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A flameless atomic-absorption method for determination of phosphorus is developed, employing zirconium treated graphite tubes. The great improvement of the sensitivity with these tubes eliminates the necessity of adding La(NO3)3. The sensitivity does not vary from tube to tube and its maximal value is attained within the first 2–3 firings. The atomization signal is practically the same within the range of 2,600–2,800° C when the rise of the temperature is high (〉 1,500° C/s). The best signal to noise ratio is obtained at 2,600° C. The detection limit is 0.05 ppm with injection of 50 μl. The method is applied to the analysis of a standard steel sample.
    Notes: Zusammenfassung Durch Verwendung einer ZrC-beschichteten Graphitrohrküvette wurde eine wesentliche Erhöhung der Empfindlichkeit erzielt, ohne daß eine Zugabe von La(NO3)3 nötig wäre. Bei Küvettenwechsel ändert sich die Empfindlichkeit nicht. Das maximale Signal wird während der ersten 2–3 Bestimmungen erreicht. Das Atomisierungssignal bleibt im Bereich zwischen 2600 und 2800 °C praktisch unverändert. Das Signal/Rausch-Verhältnis ist bei 2600 °C am größten. Die Nachweisgrenze beträgt 0,05 ppm bei 50 μl. Die Methode wurde zur Analyse von Stahlstandardproben angewendet.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 45-45 
    ISSN: 1618-2650
    Keywords: Chromatographie, Dünnschicht ; Diphenylamin als Detektionsmittel
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 345-349 
    ISSN: 1618-2650
    Keywords: Best. von Kupfer, Blei, Zink ; Spektralphotometrie, Atomabsorption ; Flamme, chromatogr. Trennung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The sample of seawater (51) is freed from solid particles, buffered at pH 5.6 and percolated through a column filled with ED3A. After sample passage 15 ml 1 M hydrochloric acid solution are pumped through the column to dissolve the concentrated ions. The final measurement using flame atomic absorption is carried out in the hydrochloric acid solution. The total labour time is less than 15 min. The standard deviations (4 analyses) for the determination of Cu, Pb and Zn (in the normal concentration range of 2–6 μg · l−1) were 2–5%, 5% and 1–10%, the recoveries 100%, 102% and 104%, respectively. A concentration coefficient of 300–500 was obtained.
    Notes: Zusammenfassung Die Probe Meereswasser (51) wird nach Entfernen der festen Teilchen auf einen pH-Wert von 5,6 gepuffert und durch eine Trennsäule mit ED3A geführt. Die angereicherten Metallionen werden mit 15 ml 1 M HCl-Lösung eluiert. Anschließend erfolgt die Bestimmung durch Flammenatomabsorption. Die Methode erfordert insgesamt weniger als 15 min Arbeitszeit. Die Standardabweichungen (4 Best.) betragen für Cu, Pb und Zn (im normalen Bereich von etwa 2–6 μg·l−1) etwa 2–5%, 5% und 1–10%, die Wiederfindungsraten 100%, 102% bzw. 104%. Der Konzentrationskoeffizient beträgt 300 bis 500.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 135-139 
    ISSN: 1618-2650
    Keywords: Best. von Chrom ; Spektralphotometrie, Atomabsorption ; Störung durch Fremdelemente
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The interfering effect of thirty six metal salts on chromium absorbance in the air-acetylene flame has been studied. The interference does not depend on the boiling point of the added foreign metals or particle size as previously assumed but is postulated to result from the formation of mixed oxides or bimetallic species or from suppression of ionized gaseous chromium pressure. The effect of the alkali sulphates as releasing agents in the determination of chromium has been tested and results show that they can be used to eliminate both suppressive and enhancing interferents.
    Notes: Zusammenfassung Die Störungsmöglichkeiten von 36 verschiedenen Metallsalzen bei der AAS-Bestimmung von Chrom mit Hilfe der Luft-Acetylen-Flamme wurden systematisch untersucht. Dabei stellte sich heraus, daß der Einfluß dieser Salze nicht — wie früher angenommen — vom Siedepunkt der betreffenden Metalle oder der Teilchengröße abhängt, sondern von der Bildung von Mischoxiden, Bimetallverbindungen oder von der Herabsetzung des Chromdampfdrucks. Weiterhin wurde die Wirkung von Alkalisulfaten als Releasing-Reagentien untersucht und gefunden, daß diese sowohl bei abschwächender als auch verstärkender Wirkung angewendet werden können.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 128-134 
    ISSN: 1618-2650
    Keywords: Best. von Chrom ; Spektralphotometrie, Atomabsorption ; Arbeitsbedingungen, Einflüsse
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wurde die Vielfältigkeit der Einflüsse von Mineralsäuren, Lösungsgenossen, Brennererwärmung und der Wertigkeit des Ions, welche insgesamt die Bestimmung von Chrom mittels AAS sehr problematisch gestalten, systematisch untersucht. Durch Verwendung einer brenngasarmen Acetylen-Lachgasflamme werden diese Schwierigkeiten weitestgehend beseitigt, was an hochprozentigen Normstählen demonstriert wird.
    Notes: Summary The variety of influences, such as mineral acids, heating of the burner head, solvent components and valency of the ion, was examined systematically. By use of a lean acetylene-nitrous oxide flame these difficulties can by eleminated extensively, and this is demonstrated on high chromium standard steels.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 22
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 159-160 
    ISSN: 1618-2650
    Keywords: Best. von Lithium ; Spektralphotometrie, Atomabsorption ; Graphitrohrküvette, Isotopie-Effekte
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 369-373 
    ISSN: 1618-2650
    Keywords: Chromatographie, Dünnschicht ; vollautomat. Auswertung von Chromatogrammen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es werden vollautomatische DC-Photometer beschrieben, bei denen ein Rechner die optimale Positionierung der DC-Flecke im Meßspalt steuert. Es lassen sich nicht nur die normalen Meßkurven, sondern auch die gemäß der Kubelka-Munk-Funktion transformierten Kurven für die Auswertung heranziehen. Infolge der Steuerung des Wellenlängenantriebes lassen sich auch Zweiwellenlängentechniken simulieren. Für die Auswertung eignet sich auch die 1. Ableitung der Meßkurve. Die Genauigkeit und Reproduzierbarkeit wird gesondert nach Auftragefehler, Meßfehler, Positionierfehler und Fehler der Chromatographie ausgewiesen.
    Notes: Summary Automated photometers for evaluating TLC plates by an optimized positioning of the spots in respect to the centre of the light beam are described. The evaluation can be performed by using the original measuring curve or a transformed one in respect to the Kubelka-Munk function. Two-wavelength techniques can be simulated, for the monochromator is controlled by the computer. This method has an advantage in measuring not well separated spots. In this case also an evaluation of the first derivative is often successful. The accuracy and reproducibility is given in respect to the different sources of errors: spotting, measurement, positioning and chromatography.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 337-344 
    ISSN: 1618-2650
    Keywords: Best. von Selen ; Spektralphotometrie, Atomabsorption ; Spuren, Hydrid, Elementquerstörungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Natriumborhydrid-Reduktionsmethode zur Austreibung des Selens aus sauren Probenlösungen in Kombination mit einer AAS-Bestimmung des Selens in einer geheizten Quarzküvette (Hydridsystem MHS-1 der Firma Bodenseewerk Perkin-Elmer, Überlingen) wird durch die Gegenwart zahlreicher Begleitelemente selbst im Spurenbereich gestört. Bei der Bestimmung von 5–100 ng Se in 20 ml 0,3 N salzsaurer Probenlösung verursachen ca. 0,7 μg Ag+;1,5 μg Sb3+;3 μg Au3+; 5 μg Cu2+; 6 μg As3+; 25 μg Sb5+; 30 μg As5+; 60 μg Ni2+; 200 μg Pt4+ bzw. Mn7+; 700 μg Co2+; 1,5 mg Pb2+; 3 mg Cr6+ und 5 mg Hg2+ jeweils Erniedrigungen des Se-Signals um 50%. 4 μg Sn2+/Sn4+ bzw. 6 μg Bi3+ führen zu einer 30 %igen Erniedrigung. Fe2+/Fe3+ stören ab Mengen ≥400 μg. Te4+ ≤ 300 μg, Alkali- und Erdalkalimengen≤25 mg sowie Mengen ≤ 5mg Al3+, Cr3+, Mn2+ und Zn2+ waren ohne Einfluß auf die Ausbeute der Selenhydrid-Bildung. Die Störungen sind stark abhängig von der vorgegebenen HCl-Konzentration in der Probenlösung. Weitere Quellen für systematische Fehler des Verfahrens wurden untersucht und teilweise behoben. Das Hydrid-AAS-Verfahren kann nicht zur direkten Bestimmung von Selenspuren (ng/g-Bereich) in metallischen, geologischen und biologischen Matrices empfohlen werden, wenn die Gehalte der störenden Begleitelemente in der Probe bestimmte Grenzkonzentrationen überschreiten, die numerisch stark von der apparativen Anordnung und den Versuchsparametern abhängen.
    Notes: Summary The sodium boro hydride-reduction method for the liberation of selenium from acid sample solutions in connection with its determination by AAS using a heatable optical cell made of quartz (hydride system MHS-1, Bodenseewerk Perkin-Elmer, Überlingen, F.R.G.) is interfered with by numerous concomitant elements occurring even in the trace range in the sample solution. In the determination of 5–100 ng of selenium in 20 ml sample solution 0.3 N in HCl, 0.7 μg of Ag+; 1.5 μg of Sb3+; 3 μg of Au3+; 5 μg of Cu2+; 6 μg of As3+;25 μg of Sb5+; 30 μg of As5+; 60 μg of Ni2+; 200 μg of Pt4+ and Mn7+; 700 μg of Co+; 1.5 mg of Pb2+; 3 mg of Cr6+ and 5 mg Hg2+ cause a depression of the Se-signal of 50%. 4 μg of Sn2+/Sn4+ and 6 μg of Bi3+ cause a depression of 30%. Fe2+ /Fe3+ interfere only if present in quantities ≥400 μg. Te4+ in quantities ≤300 μg, alkali metals and alkaline earths ≤25 mg, and Al3+, Cr3+, Mn2+ and Zn2+ ≤5 mg do not affect the selenium hydride formation. The interferences depend very strongly on the used HCl concentration in the sample solution. Further sources of systematic errors are investigated and partly eliminated. The hydride-AAS procedure cannot be recommended for the determination of traces of selenium (ng/g-range) directly in metallic, geological or biological matrices, if the levels of the interfering concomitants reach above a certain threshold concentration, which numerically depend strongly on the apparatus and the parameters of the analysis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 374-376 
    ISSN: 1618-2650
    Keywords: Best. von Cadmium in Aluminium ; Spektralphotometrie, Atomabsorption ; Verflüchtigung aus Reinstaluminium
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird ein Verfahren zur Bestimmung kleinster Mengen Cadmium beschrieben, bei dem Cadmium zunächst aus Reinstaluminium verflüchtigt und dann im Wasserstoffstrom entweder on-line oder off-line mit der flammenlosen AAS bestimmt wird. 23 ppb Cadmium konnten bestimmt werden.
    Notes: Summary A method is described for the determination of low concentrations of cadmium. In the first step cadmium is volatilized out of very pure aluminium and subsequently determined in a H2 stream either off-line or on-line with flameless AAS. 23 ppb of cadmium could be determined.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 377-379 
    ISSN: 1618-2650
    Keywords: Best. von Arsen in Blei, Bleilegierungen ; Spektralphotometrie, Atomabsorption ; Red. zu Arsin
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird ein Verfahren zur Bestimmung von μg/g- bis mg/g-Gehalten Arsen in Blei und Bleilegierungen beschrieben. Das Arsen wird dazu mit NaBH4 als AsH3 aus der Probenlösung ausgetrieben und atomabsorptions-spektrometrisch in einer geheizten Quarzküvette bestimmt. Durch geeignete Arbeitsbedingungen werden Störungen durch die Matrix ausgeschaltet. Für den gesamten Arbeitsbereich beträgt die relative Standardabweichung etwa 3% (N=12); die Nachweisgrenze (3 σ-Grenze) wurde zu 0,1 μg/g As ermittelt.
    Notes: Summary A method is described for the determination of μg/g to mg/g concentrations of As in lead and lead alloys. For that purpose arsenic is blown out from the sample solutions as AsH3 by use of NaBH4 and determined by AAS in a heated quartz cuvette. Using suitable conditions disturbances caused by the matrix are eliminated. The relative standard deviation over the whole working range is about 3% (N=12); the detection limit (3 σ) was found to be 0.1 μg/g As.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 296 (1979), S. 114-124 
    ISSN: 1618-2650
    Keywords: Best. von Spurenelementen, Schwermetallen in Wasser ; Spektralphotometrie, Atomabsorption ; Bodensee
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Monatliche AAS-Messungen im Jahre 1977 auf die Elemente As, Pb, Cd, Cr, Hg, Se, Zn, Fe, Mn, Ni, Co, Al und B im Rohwasser und im Trinkwasser des Zweckverbandes Bodenseewasserversorgung sowie an ausgewählten Tiefenprofilen im Überlinger See werden diskutiert. Die angewandten Untersuchungsmethoden werden eingehend erläutert. Die Ergebnisse zeigen, daß der Gehalt der toxischen Metalle im Bodenseewasser unter 1% der laut Trinkwasserverordnung zulässigen Grenzkonzentrationen liegt. Die höchsten Konzentrationen mit maximal 7% des Grenzwertes wurden beim Element Arsen gefunden — eine für die Bodenseetrinkwasserwerke jedoch immer noch beruhigende Zahl. Dennoch soll speziell diesem Element in weitergehenden Untersuchungen erhöhte Aufmerksamkeit gewidmet werden.
    Notes: Summary A survey is given based on monthly measurements over a one-year period (1977) to determine the trace metals in the raw and drinking water and in two vertical profiles of the Lake of Constance (Überlinger See) by means of atomic absorption spectrometry. The methods used are discussed in detail. The results showed that the content of the toxic metals Hg, Se, Pb, Cr and Cd amounts to less than 1% of the concentration limits due to German law. The highest concentrations were found for the element As, which reached about 7% of the limiting concentration. Further investigations are therefore concerned with this element.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 294 (1979), S. 135-139 
    ISSN: 1618-2650
    Keywords: Trenn. von Benzodiazepinen ; Chromatographie, Dünnschicht ; Metaboliten
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die DC-Trennung von 14 1,4- bzw. 1,5-Benzodiazepinen und 17 Hauptmetaboliten sowie die Detektion mit Bratton-Marshall-, Dragendorff- und Jodoplateat-Reagens werden beschrieben. Rf-Werte sowie die Reaktionen mit den Reagentien sind tabellarisch zusammengestellt und Biotransformationsschemata angegeben.
    Notes: Summary Experimental details for the separation are described and data are compiled for Rf-values and reactions with Bratton-Marshall, Dragendorff and iodoplateate-reagents. Biotransformation schemes for the individual benzodiazepines are presented.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 29
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 294 (1979), S. 288-288 
    ISSN: 1618-2650
    Keywords: Nachw. von Ioxynil in Biolog. Material ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 30
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 295 (1979), S. 263-265 
    ISSN: 1618-2650
    Keywords: Trenn. von Alkoholen ; Chromatographie, Dünnschicht ; C1-C20, 6 Trennsysteme, Dinitrobenzoate
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Thin-layer chromatography on rice starch, maize starch, cellulose and talc makes possible the separation of the homologous series of 3,5-dinitrobenzoates of aliphatic alcohols C1 to C20. Six different solvent systems have been employed. Dependence of R f-values on the number of C-atoms on various supports is discussed.
    Notes: Zusammenfassung Mit Hilfe der Dünnschicht-Chromatographie auf Reisstärke, Maisstärke, Cellulose und Talk wurde die homologe Reihe der 3,5-Dinitrobenzoate von aliphatischen Alkoholen C1 bis C20 getrennt. Sechs verschiedene Fließmittel wurden benutzt. Die Abhängigkeit der R f-Werte von der Zahl der C-Atome auf verschiedene Schichten wird diskutiert.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 299 (1979), S. 261-263 
    ISSN: 1618-2650
    Keywords: Best. von Kupfer in Zirkoniumsalzen ; Spektralphotometrie, Atomabsorption ; HF-Zusatz
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary An AAS method is described for the direct determination of traces of copper in zirconium(IV) oxide chloride and nitrate. An interference study of the zirconium matrix is reported. Best conditions for the removal of the suppressive effect of zirconium on the copper signal by addition of hydrofluoric acid are described. Results obtained by analyzing commercial samples from different manufacturers are presented.
    Notes: Zusammenfassung Kupferverunreinigungen wurden in Zirkoniumoxidchlorid und -nitrat bestimmt. Störungen durch die Matrix wurden untersucht. Die abschwächende Wirkung des Zr auf das Cu-Signal wurde durch Zusatz von Fluorwasserstoffsäure beseitigt. Analysenergebnisse für verschiedene handelsübliche Zr-Salze werden mitgeteilt.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 295 (1979), S. 272-272 
    ISSN: 1618-2650
    Keywords: Trenn. von Arylazopyraolen ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 297 (1979), S. 44-48 
    ISSN: 1618-2650
    Keywords: Best. von Uran ; Spektralphotometrie, Atomabsorption ; Verbesserung durch Interferenzzusätze
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die nachstehend beschriebene Untersuchung zeigt, daß manche Metallionenzusätze Empfindlichkeitsverbesserungen bei der Bestimmung des Urans durch Flammen-AAS ergeben. Als wirksamster Zusatz wurde Gallium gefunden, das die Empfindlichkeit gegenüber reiner Uranlösung etwa um den Faktor 5 steigern kann. Durch die Anwendung der sogenannten Injektionsmethode kann mit kleinsten Probevolumen die zur Analyse notwendige Absolutmenge des Urans bis zur Nachweisgrenze von 0,5 μg vermindert werden. Zusätzlich wurde die bewährte Uran-Extraktions-Aufkonzentrierungsmethode mit Triphenylarsinoxid in CHCl3 für die AAS modifiziert, womit in vielen Fällen eine weitere Erniedrigung der Nachweisgrenze erzielt werden kann.
    Notes: Summary This paper describes some improvements in the sensitivity of the uranium analysis by atomic absorption spectrometry as obtained by addition of certain metallic ions to the solution in question. Thus a factor of about 5 can be achieved by addition of 10 mg of gallium/ml. By applying the injection method very small amounts of uranium down to 0.5 μg can be analyzed. The very efficient purification and concentration of the uranium by extraction with triphenylarsine oxide in chloroform was adapted to this AAS procedure, thus allowing even lower limits of detection.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 297 (1979), S. 381-383 
    ISSN: 1618-2650
    Keywords: Best. von Chrom(III), Chrom(VI) in Was-ser ; Spektralphotometrie, Atomabsorption ; Extraktion mit APDC-MIBK
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary With the well-known APDC-MIBK extraction of dissolved trace metals from aqueous solutions for AAS analysis only Cr6+ is determined, whereas practically no Cr3+ is extracted. This technique was therefore modified (PHP-buffer; pH 4.7–5.5; 80° C; 20 min reaction time) so that hexavalent and trivalent chromium can be extracted simultaneously into the organic phase, thus allowing determination of the percentage of each of these ionic species in water (hexavalent chromium being determined separately). A procedure for the modified extraction is described.
    Notes: Zusammenfassung Mit der bekannten APDC-MIBK-Extraktion gelöster Spurenmetalle aus wäßrigen Lösungen für die AAS-Analyse wird nur Cr6+ erfaßt, während Cr3+ praktisch nicht extrahiert wird. Die bisherige Methode wurde deshalb so modifiziert (PHP-Puffer; pH 4,7–5,5; 80° C; 20 min Reaktionszeit), daß mit dem sechswertigen auch das dreiwertige Chrom in die organische Phase extrahiert wird und so der Anteil beider lonenarten bestimmt werden kann (nach getrennter Bestimmung des Cr6+). Eine Arbeitsvorschrift wird angegeben.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 298 (1979), S. 123-127 
    ISSN: 1618-2650
    Keywords: Spektralphotometrie, Atomabsorption ; flammenlos, Spurenanalyse, direkte Probenzuführung in Graphitofen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die direkte Bestimmung von Spurenelementen in metallischen und oxidischen Proben im Gehaltsbereich 0,1–10 μg/g (entsprechend 10−5-10−3 Massen-%) wird beschrieben. Hierzu bietet sich die Verwendung einer speziellen Graphitofen-Boottechnik an, mit deren Hilfe die Proben direkt in fester Form eingebracht werden können. Zwei unterschiedliche Verfahren sind erforderlich: die mehrfache Aufschmelzung für metallische Proben und die zweifache Verdampfung von oxidischen Stoffen. Die Resultate beider Verfahren werden diskutiert.
    Notes: Summary The direct determination of trace elements of metallic and oxidic samples in the range of 0.1–10 μg/g (or 10−3–10−5 mass-%) is described by using a special graphite furnace boat-technique with direct sample input. Two different procedures are necessary: a multiple heating technique in case of metallic samples and a double vapourization technique in case of oxides. The results using both techniques are discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 294 (1979), S. 36-41 
    ISSN: 1618-2650
    Keywords: Trenn. von Antimikrobiellen Verbindungen ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Trennung und Identifizierung von halogenierten, vorwiegend aliphatischen antimikrobiellen Verbindungen, von Formaldehyd abgebenden Substanzen und von Sulfonsäure-Derivaten auf dünnschicht-chromatographischem Wege wird beschrieben. Die Trennung erfolgt auf einer Kieselgel-Cellulose-Mischschicht mit Äthylacetat/Methanol/10% Ammoniak (65+30+5) als Laufmittel. Zur Sichtbarmachung und zur Identifizierung sind mehrere Sprühmittel notwendig: äthanolischeMethylgelb-Lösung mit anschließender UV-Bestrahlung, Phenylhydrazinsulfonat und Natronlauge sowie Hydroxylamin/Eisen(III)-chlorid und Nitroprussidnatrium-Kaliumhexacyanoferrat (III) u. a. Anhand der verschiedenen Rf-Werte und der Anfärbungen lassen sich die antimikrobiellen Verbindungen rasch und einfach identifizieren.
    Notes: Summary The analysis of halogenated, mainly aliphatic compounds, of formaldehyde donors and of derivatives of sulphonic acid is described. The separation is carried out on plates coated with a mixed layer of silica gel and cellulose and a solvent mixture of ethylacetate/methanol/10% ammonia (65+30+5), whereas for the detection and identification several spray reagents have to be used: ethanolic solution of Methyl Yellow with subsequent UV irradiation, phenylhydrazine-4-sulphonic acid and sodium hydroxide, hydroxylamine/iron(III) chloride, sodium nitroprusside/potassium hexacyanoferrate(III) and others. The Rf-values and the colourations of the spots allow to identify the examined compounds rapidly and without further chemical procedures.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 294 (1979), S. 42-42 
    ISSN: 1618-2650
    Keywords: Trenn. von anorg. Ionen ; Chromatographie, Dünnschicht ; DCTA-imprägniert
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 294 (1979), S. 414-414 
    ISSN: 1618-2650
    Keywords: Identifizierung von Arylhydrazin-benzylsulfonylmethylpyrazolinonen ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 299 (1979), S. 190-193 
    ISSN: 1618-2650
    Keywords: Best. von Bismut in Pflanzenmaterial, Tee, Laub ; Spektralphotometrie, Atomabsorption ; Graphitrohrküvette, Xylolextraktion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A sensitive method for the extraction and atomic absorption spectrometric measurement with electrothermal atomization has been developed for the determination of bismuth in tea and orchard leaves. Bismuth is extracted into m-xylene as diethyldithiocarbamate complex. 2.5–3.0 l/min of argon flow rate, 650–800° C of ashing temperature and 2,200–2,600° C of atomization temperature were the best experimental conditions. A detection limit of 0.02 ng was obtained with a precision of 2–7% and minimal interference effects.
    Notes: Zusammenfassung Ein empfindliches Verfahren zur Bi-Bestimmung in Tee und Blättern von Obstbäumen wurde ausgearbeitet. Bismut wird dabei als Diethyldithiocarbamat mit m-Xylol extrahiert. Optimale Arbeitsbedingungen sind: 2,5–3 l Argon/min, 650–800° C Veraschungstemperatur, 2200–2600° C Atomisierungstemperatur. Nachweisgrenze ist 0,02 ng und die Reproduzierbarkeit beträgt 2–7%. Störeffekte durch andere Elemente sind gering.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 299 (1979), S. 207-207 
    ISSN: 1618-2650
    Keywords: Analyse von Sulfonamiden ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 299 (1979), S. 362-367 
    ISSN: 1618-2650
    Keywords: Best. von Silber, Gold, Bismut, Kupfer, Palladium in Blei ; Spektralphotometrie, Atomabsorption ; Anreicherung durch partielle Fällung der Matrix mit NaBH4
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Gruppen von Elementspuren können aus unterschiedlichen Probenmaterialien quantitativ angereichert werden, wenn man einen geringen Anteil der Matrix durch Zusatz von NaBH4 reduktiv ausfällt. Der metallische Niederschlag wirkt dabei als Spurenfänger für alle Elemente, die elektrochemisch edler sind als die Matrix. Als Beispiel für diese Anreicherungstechnik wurden Spuren Ag, Au, Bi, Cu und Pd aus Proben von 10 g Feinblei angereichert und nach Auflösen des Spurenfängers in Säure durch Flammen-Atomabsorptions-Spektrometrie bestimmt. Bei Spurengehalten von wenigen μg/g werden rel. Standardabweichungen um 5 % erzielt; die Nachweisgrenzen liegen — je nach Element — zwischen 0,05 und 0,4 μg/g. Die Richtigkeit des Analysenverfahrens wurde anhand analysierten Probenmaterials sichergestellt.
    Notes: Summary Selected groups of trace elements can be preconcentrated from different materials by precipitation of a small amount of the matrix with NaBH4 as a reducing agent. The metallic precipitate serves as a trace collector for all elements being electrochemically nobler than the matrix. As an example for this technique traces of Ag, Au, Bi, Cu, and Pd are enriched from samples of 10 g pure lead and, after dissolving the collector in acid, determined by flame atomic absorption spectrometry. With trace contents of a few μg/g relative standard deviations of about 5 % are achieved. Depending on the element, the limit of detection was found to be between 0.05 and 0.4 μg/g. The accuracy of the analytical procedure was verified by use of analysed reference samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 42
    ISSN: 1618-2650
    Keywords: Best. von Thallium in Nickellegierungen, Cobaltlegierungen ; Spektralphotometrie, Atomabsorption ; Graphitofen, Spuren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A simple and rapid analytical method has been developed for the direct determination of trace quantities of thallium in nickel and cobalt-base heatresisting alloys by graphite furnace atomic absorption spectrometry. Hydrofluoric acid, sulphuric acid, and hydrogen peroxide were used for the dissolution of a wide variety of these alloys. The interferences of matrix elements and acids were eliminated. The absorbance of thallium is constant over a wide range of ashing temperatures. Synthetic standard solutions composed of nickel or cobalt matrix and thallium were used for calibration. The detection limit for thallium by this method is 0.2 ppm in the sample. Mechanisms of the interferences are discussed.
    Notes: Zusammenfassung Ein Verfahren zur AAS-Bestimmung von Thallium in verschiedenartigen Cobalt- und Nickellegierungen wird beschrieben. Zur Auflösung der Probe werden Flußsäure, Schwefelsäure und Wasserstoffperoxid verwendet. Störungen durch Matrixelemente und durch die Säuren konnten beseitigt werden. Die Thalliumabsorption ist über einen weiten Temperaturbereich bei der Veraschung konstant. Zur Eichung dienen synthetische Lösungen von Cobalt- bzw. Nikkelmatrix und Thallium. Die Nachweisgrenze für Thallium beträgt 0,2 ppm. Die Mechanismen der Störungen werden diskutiert.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 299 (1979), S. 368-374 
    ISSN: 1618-2650
    Keywords: Best. von Chrom in Serum, Plasma ; Spektralphotometrie, Atomabsorption ; flammenlos
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die bis heute in der Literatur mitgeteilten Werte für Chrom im Serum nüchterner gesunder Probanden unterscheiden sich um Größenordnungen. Die in der vorliegenden Arbeit mitgeteilten Untersuchungen betreffen die analytische Problematik der Chrombestimmung mit Hilfe der flammenlosen Atomabsorptions-Spektrometrie, wobei aufgezeigt wird, daß diese Methodik für die Chrombestimmung in biologischem Material ohne großen statistischen Aufwand zu keiner sicheren Beurteilbarkeit und Interpretierbarkeit der gemessenen Werte führt. Mit Hilfe synthetischer Chromkomplexverbindungen werden die Probleme der Standardaddition zur Chrombestimmung untersucht. Unter Berücksichtigung der Blindwerte und der daraus resultierenden Nachweisgrenze sowie Garantiegrenze für Reinheit, wurde Chrom in einem Standardreferenzmaterial (1569 Brewers yeast [U. S. National Bureau of Standards]) im Rahmen eines Ringversuchs zur Chromanalyse sowie im Serum und Plasma von 41 Probanden bestimmt. Für das Referenzmaterial wurde ein Wert von 45±4 μmol/kg (2,3±0,2 μg/g) ermittelt. Der Referenzwert betrug 41±1 μmol/kg (2,12±0,05 μg/g). Im Serum wird eine lognormale Verteilung der Chromkonzentration mit den zentralen Parametern ±_M=13▴2,2 nmol/l (0,7▴2,2 μg/l) ermittelt. Im Plasma lagen die Werte zwischen 20 und 30 nmol/l (1–1,5 μg/l). Aufschluß, Durchführung der Bestimmung sowie die biologische Bedeutung und Interpretation des Parameters Chrom im Serum und Plasma werden eingehend diskutiert.
    Notes: Summary Concentrations of Cr in serum of overnight fasting volunteers differ over a wide range in the literature. The investigations of the analytical problems of Cr determination by flameless atomic absorption spectrometry underline the necessity of statistical methods for the interpretation of the measurements of Cr in biological matrices. With nine different synthetic chromium complexes the method of standard addition was investigated. Considering the blank values, the limit of detection and the limit of guarantee for purity, Cr was determined in the standard reference material 1569 brewers yeast (National Bureau of Standards) with 45±4 μMol · kg−1 (2.3±0.2μg·g−1), compared with the reference data 41±1 μMol·kg−1 (2.12±0.05 μg±g−1). In serumuuuuu we found a lognormal distribution with the central parameters 13▴2.2 nMol ·1−1 (0.7▴2.2 μg·1−1). In plasma the values were in the range between 20 and 30 nMol·1−1 (1–1.5 μg·1−1). The ashing process and the determination are demonstrated and discussed in detail.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 291 (1978), S. 213-216 
    ISSN: 1618-2650
    Keywords: Best. von Blei in Boden, Sedimenten ; Spektralphotometrie, Atomabsorption ; Flamme, Reextraktion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung In Vorversuchen wurde gezeigt, da\ beim Aufbewahren der organischen APDC/MIBK-Extrakte starke Bleiverluste auftraten. Daher war es notwendig, das Blei mit SalpetersÄure in die wÄ\erige Phase zu reextrahieren. Wiederfindungsversuche bestÄtigten, da\ Extraktion und Reextraktion quantitativ verlaufen. Das Blei wird dabei um den Faktor fünf angereichert. Es werden mittlere Standardabweichungen für vier Konzentrationsbereiche angegeben. Als Nachweisgrenze wurde eine Konzentration von 0,16 mg Pb/l gefunden, die durch die Anreicherung auf ca. 0,03 mg Pb/l gesenkt wird. Arbeitsvorschriften für das Verfahren sind angegeben.
    Notes: Summary Preliminary investigations have shown, that considerable losses of lead occur during storage of the organic APDC/MIBK-extracts. Therefore, it was necessary to reextract lead into the aqueous phase by nitric acid. Investigations of recoveries confirmed, that extraction and reextraction of lead were quantitative. In this way the concentration of lead is increased by a factor of five. Mean standard deviations for four concentration ranges are given. A detection limit of 0.16 mg of Pb/l is obtained, which is lowered by the preceding enrichment to about 0.03 mg of Pb/l. Details of the procedure are given.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 381-384 
    ISSN: 1618-2650
    Keywords: Best. von Aminen, aromat. ; Chromatographie, Dünnschicht ; Remissionsmessung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird eine Methode zur quantitativen Bestimmung von aromatischen Aminen beschrieben. Diese werden dünnschicht-chromatographisch auf Kieselgel 60 F254 Fertigplatten in den Laufmitteln n-Propanol/Methanol/Wasser/Eisessig (65∶15∶15∶20; Vol.) oder n-Butanol/Wasser/Eisessig (66∶17∶17; Vol.) von den Begleitstoffen abgetrennt. Die getrennten Aminflecke werden entweder im Ultraviolett-Bereich oder nach Diazotierung im sichtbaren Bereich mit dem Chromatogramm-Spektralphotometer PMQ II nach der Remissionsmethode gemessen und anhand der auf derselben Platte aufgestellten Eichgerade ausgewertet. Die quantitative Bestimmung wird anhand der beiden Amine 5-Amino-2,4,6-trijod-isophthalsäurebis-(2,3-dihydroxy-propyl-N-methylamid) (I) und 2,4,6-Trijod-3-aminobenzoesäure (II) in Röntgenkontrastmittelpräparaten (RKP) demonstriert. Sowohl im UV- als auch im sichtbaren Bereich, läßt sich in 3000 μg RK-Säure (RKS) noch 0,1 μg freies aromatisches Amin, das sind 0,003%, bezogen auf die eingesetzte Menge RKS, mit einer maximalen relativen Standardabweichung von 4% bestimmen. Diese Methode ist spezifischer und empfindlicher als die der Diazotierung in Lösung.
    Notes: Summary The aromatic amines are separated from impurities by thin-layer chromatography on silica gel 60 F254 precoated plates in the mobile solvents n-propanol/methanol/water/glacial acetic acid (65∶15∶15∶20; vol.) or n-butanol/water/glacial acetic acid (66∶17∶17; vol.). The separated amine spots are measured by the remission method by means of the TLC densitometer PMQ II, either in the u.v. region or, after diazotization, in the visible region, and evaluated on the basis of the linear calibration curve set up on the same plate. Quantitative determination is demonstrated by means of the two amines, 5-amino-2,4,6-triiodoisophthalic acid-bis-(2,3-dihydroxypropyl-N-methylamide) (I) and 2,4,6-triiodo-3-aminobenzoic acid (II), in radiopaque contrast media (RCM). Both in the u.v. and visible regions, it is still possible to determine 0.1 μg of free aromatic amine in 3000 μg of radiopaque contrast medium acid (RCA), or 0.003% in terms of the amount of RCA used, with a maximum relative standard deviation of 4%. This method is more specific and more sensitive than that of diazotization in solution.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 46
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 293 (1978), S. 135-137 
    ISSN: 1618-2650
    Keywords: Analyse von Desodorantien, Phenolderivaten in Kosmetika ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Phenolische Desodorantien in kosmetischen Präparaten lassen sich durch Umsetzung mit Echtrotsalz Al (Anthrachinondiazonium-chlorid-1) in wäßrig-alkalischer Lösung, Extraktion des gebildeten Azofarbstoffes mit einem organischen Lösungsmittel und anschließender Dünnschicht-Chromatographie schnell identifizieren. In den meisten Fällen ist die Abhängigkeit zwischen der Extinktion der Farbstofflösung und der eingesetzten Menge des betreffenden Desodorants linear, wodurch dann auch quantitative Bestimmungen möglich sind.
    Notes: Summary Phenolic compounds, used as deodorants in cosmetic products can be identified quickly by reaction with anthraquinonediazonium chloride-1 (Echtrotsalz Al) in aqueous alkaline medium, extraction of the azo dye with an organic solvent and separation by thinlayer chromatography. The relation between the absorbance of the coloured solution and the concentration of the deodorant concerned is generally linear; in these cases quantitative determinations are always possible.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 293 (1978), S. 141-144 
    ISSN: 1618-2650
    Keywords: Best. von Quecksilber in Zähnen, Knochen ; Spektralphotometrie, Atomabsorption ; HNO3/HF-Aufschluß, Kaltdampfverfahren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird ein Verfahren zur Bestimmung von Quecksilber in Zahnwurzeln und Kieferknochen beschrieben. Die homogenisierten Proben werden in Teflonbomben unter Druck mit einem Gemisch von HNO3/HF aufgeschlossen. Die Quecksilberbestimmung erfolgt mit einem Atomabsorptionsspektrophotometer nach dem Kaltdampfverfahren. Unter Einsatz von 200 mg Probe können Quecksilbergehalte bis zu 0,1 μg/g bestimmt werden. Die relativen Standardabweichungen liegen im Arbeitsbereich von 10–100 ng Quecksilber zwischen 2,7 und 5,6 %. Es wurden Quecksilbergehalte von 〈0,1–187 μg/g in den Proben gefunden.
    Notes: Summary The homogenized samples are decomposed with a mixture of HNO3/HF in teflon vessels under pressure. The determination of mercury is carried out with an atomic absorption spectrophotometer by means of the cold-vapour technique. The limit of detection is 0.1 μg/g for a 200 mg sample. A relative standard deviation of 2.7–5.6% is achieved in the working range of 10–100 ng mercury. Mercury contents of 〈0.1–187 μg/g were found in the samples.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 291 (1978), S. 366-368 
    ISSN: 1618-2650
    Keywords: Nachw. von N-Heterocycl. Verbindungen ; Chromatographie, Dünnschicht ; CuSO4-imprägnierte Schichten, Fluorescenz
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Durch die charakteristischen Fluorescenzfarben und die Fluorescenz-Thermochromie der CuJ-Komplexe lassen sich N-Heterocyclen auf Chromatogrammen meist einwandfrei identifizieren. Eine wesentliche Vereinfachung wird durch die Verwendung CuSO4-imprägnierter Kieselgelschichten erreicht. Die Nachweisempfindlichkeiten insbesondere bei tiefer Temperatur ändern sich im Vergleich zur ursprünglichen Technik kaum.
    Notes: Summary N-Heterocycles can usually be identified with certainty through the characteristic fluorescence colours and fluorescence-thermochromism of the CuI-complexes. The use of CuSO4-impregnated silica gel layers facilitates the procedure considerably, and scarcely reduces the sensitivity of detection, particularly at low temperature.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 282-284 
    ISSN: 1618-2650
    Keywords: Best. von Wismut in Aluminiumlegierungen, Lötlegierungen ; Spektralphotometrie, Atomabsorption ; Zinkdibenzyldithiocarbamat
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A sensitive method for the extraction and atomic-absorption spectrometric determination of bismuth with zinc dibenzyldithiocarbamate (ZnDBC) has been developed for aluminium alloys and solder alloys. Bismuth is extracted from relatively strong acidic solution into methyl isobutyl ketone (MIBK) as BiDBC complex and its concentration is determined by spraying the MIBK extract into an air-acetylene flame. Iron and copper up to 1 mg resp. 100 μg did not interfere with the extraction of bismuth in the range of 0–80 μg. The limit of detection was about 0.12 ppm in MIBK.
    Notes: Zusammenfassung Ein empfindliches Verfahren zur Wismutbestimmung mit Zinkdibenzyldithiocarbamat wurde ausgearbeitet. Wismut wird dabei aus relativ stark saurer Lösung als Bi-DBC-Komplex mit Methylisobutylketon extrahiert und zur Messung der Extrakt direkt in die Luft-Acetylen-Flamme gesprüht. Bis zu 1 mg Fe und 100 μg Cu stören die Bestimmung von 0–80 μg Bi nicht. Die Nachweisgrenze beträgt 0,12 ppm in Methylisobutylketon.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 50
    ISSN: 1618-2650
    Keywords: Best. von Quecksilber ; Spektralphotometrie, Atomabsorption ; Kaltdampf, Vergleich der Reduktion mit NaBH4-Tablette oder SnCl2-Lösung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary An atomic-absorption spectrophotometric method for the rapid and precise determination of mercury has been studied by using the sodium borohydride tablet reduction and cold-vapour atomicabsorption procedure coupled with amalgamation on gold. The comparison of the sodium borohydride tablet and tin(II) chloride solution reducing systems are described in detail. The use of the sodium borohydride tablet wrapped in a wafer sheet is very simple and gives more precise results. From the comparison of the effect of diverse ions, it is obvious that both reducing systems have their merits and demerits.
    Notes: Zusammenfassung Ein atomabsorptions-spektralphotometrisches Kaltdampf-Verfahren zur schnellen Quecksilberbestimmung wird beschrieben, das auf der Reduktion mit Hilfe der Natriumborhydridtablette und der Amalgamierung mit Gold beruht. Der Vergleich mit der Zinn(II)-Chloridmethode wird diskutiert. Genaue Ergebnisse werden durch einfaches Einhüllen der Reduktionstablette in ein Waffelblatt erzielt, wodurch der Reaktionsbeginn verzögert wird. In bezug auf Störelemente ergeben sich für beide Verfahren Vor- und Nachteile.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 51
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 278-281 
    ISSN: 1618-2650
    Keywords: Best. von Blei in Algen, Diatomeen ; Spektralphotometrie, Atomabsorption ; flammenlos, Störungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird eine nasse HF-HClO4Veraschungsmethode von biologischem Material in offenen PTFE-Reagensgläsern beschrieben. In anschließenden flammenlosen AAS-Messungen mit Hilfe der Deuterium-Untergrundkompensation und des automatischen Probenwechslers AS-1 konnte gezeigt werden, daß Silicium vollständig entfernt worden, kein meßbarer Matrix-Effekt festzustellen war und die Bleikonzentrationsbestimmung durch eine Eichgerade und durch Standard-Addition zu gleichen Werten führte. Die Methode ist mit einem Variations-Koeffizient von 0,45% behaftet.
    Notes: Summary A wet HF-HClO4 decomposition method for biological material in open PTFE-test-tubes is described. Flameless AAS measurements with the aid of deuterium background compensation using the auto sampling system AS-1 showed that Si was completely eliminated by the decomposition, that no measurable matrix effect could be detected, and that the values found for the lead concentration by calibration curve and standard addition were identical. The coefficient of variation for the method was V=0.45%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 362-364 
    ISSN: 1618-2650
    Keywords: Best. von Siliciumorganoverbindungen in Wasser ; Spektralphotometrie, Atomabsorption ; Extraktionsverfahren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary An extraction technique is described for the determination of ppm concentrations of both hydrophobic and hydrophilic methylsiloxane compounds in water, based on a single extraction with a mixed solvent of (1∶1) l-pentanol and methyl isobutyl ketone followed by the determination of the silicone compounds extracted into the mixed solvent by atomic absorption spectroscopy. The method is applicable over the concentration range 0.3–30 ppm Si. Standard deviation in the case of 10 ppm Si is 0.313.
    Notes: Zusammenfassung Zur Bestimmung von ppm-Konzentrationen an hydrophoben und hydrophilen Methylsiloxanverbindungen im Wasser wird ein Extraktionsverfahren beschrieben. Hierbei wird nach einfacher Extraktion mit l-Pentanol/Methylisobutylketon (1∶1) das Silicium im Extrakt mit Hilfe der AAS bestimmt. Der erfaßbare Konzentrationsbereich liegt bei 0,3–30 ppm Si. Die Standardabweichung beträgt bei 10 ppm Si 0,313.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 53
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 415-416 
    ISSN: 1618-2650
    Keywords: Trenn. von Anorgan. Ionen ; Chromatographie, Dünnschicht ; mit p-Toluidin imprägnierte Schichten
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 293 (1978), S. 45-48 
    ISSN: 1618-2650
    Keywords: Best. von Prostaglandinen in Sperma ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A relatively simple procedure for the isolation and determination of the prostaglandins present in human seminal fluid is described. It involves preliminary chromatographic purification of these compounds from the major non-prostaglandin impurities followed by their total elution in one solvent (one-step elution). The prostaglandins thus obtained were almost free from other lipids and were further resolved into prostaglandin-groups and individual prostaglandins by repeated thin-layer chromatography. Data are also presented for prostaglandin contents of fresh semen samples from five individuals and results compared with those from the stored samples.
    Notes: Zusammenfassung Das Verfahren umfaßt eine chromatographische Abtrennung der Verbindungen von den hauptsächlichsten Verunreinigungen und die Gesamtelution mit einem Lösungsmittel. Die von anderen Lipiden fast völlig freien Prostaglandine werden durch wiederholte Dünnschicht-Chromatographie in Gruppen und Einzelverbindungen getrennt. Werte werden angegeben über die Prostaglandingehalte von frischem im Vergleich zu gelagertem Sperma.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 291 (1978), S. 20-26 
    ISSN: 1618-2650
    Keywords: Best. von Quecksilber in Biolog. Material, Umweltmaterial ; Spektralphotometrie, Atomabsorption ; AutoAnalyzer, Anreicherung an Silberwolle, ng-Bereich.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Ein modifiziertes automatisiertes Kaltdampf-AAS-Verfahren mit einem AutoAnalyzer II®-System wird beschrieben. Das Verfahren erlaubt sowohl die Bestimmung von anorganischem wie die von Gesamtquecksilber und erlaubt bis zu 120 Analysen/Tag. Die Anreicherung von Quecksilber als Amalgam an Silberwolle, gefolgt von rascher thermischer Zersetzung mit Hilfe einer Graphitküvette ermöglicht eine Nachweisgrenze von 0.01 ng/ml Probenlösung. Die relative Standardabweichung für homogenes Probenmaterial und das Gesamtverfahren ist ≤15%. Während der Analyse von Standard-Referenz-Proben wurden keine systematischen Abweichungen beobachtet. Der mittlere Gesamt-(2σ)fehler für eine einzelne Probe sollte daher 30% nicht überschreiten.
    Notes: Summary A modified automated cold vapour AAS procedure using an AutoAnalyzerII® system is described. The procedure permits the determination of inorganic as well as total mercury and enables to perform up to 120 analyses/day. The enrichment of mercury as amalgam on silver wool, followed by a fast thermal decomposition with the aid of a graphite cuvette enables a detection limit of 0.01 ng/ml sample solution. The relative standard deviation for homogeneous samples and the overall procedure is ≤15%. During the analysis of certified standard reference materials no systematic deviations were observed. The average total (2σ) error for a single sample should therefore not exceed 30%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 291 (1978), S. 127-127 
    ISSN: 1618-2650
    Keywords: Best. von Beryllium in Luft ; Spektralphotometrie, Atomabsorption ; flammenlos
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 237-237 
    ISSN: 1618-2650
    Keywords: Analyse von HCH-Salbe ; Chromatographie, Dünnschicht ; Fertigfolien
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 238-238 
    ISSN: 1618-2650
    Keywords: Trenn. von Dimethylarylazoisoxazolen ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 289 (1978), S. 17-23 
    ISSN: 1618-2650
    Keywords: Spektralphotometrie, Atomabsorption ; Auswertung, Rechnerprogramm
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Für die Auswertung der Messungen am Atomabsorptions-Spektrometer wurde ein Rechner-programm erarbeitet, das universell für die Berechnung von Analysenergebnissen nach der Bestimmung von Extinktionen verwendbar ist. Das Programm wird an einem Beispiel dargestellt.
    Notes: Summary For the calculation of analytical results a computer program is developed. It is an universal program for calculating concentrations with absorbance values of absorption methods, esp. for measurements in atomic-absorption spectroscopy.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 60
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 289 (1978), S. 110-111 
    ISSN: 1618-2650
    Keywords: Identifizierung von Pemolin-Metaboliten im Harn ; Chromatographie, Dünnschicht ; UV-, IR-, Massenspektren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 289 (1978), S. 285-286 
    ISSN: 1618-2650
    Keywords: Best. von Trimethylzinnverbindungen in Dimethylzinn-di(thioglykolsäureisooctylester) ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 289 (1978), S. 337-345 
    ISSN: 1618-2650
    Keywords: Best. von Lanthanoiden ; Spektralphotometrie, Atomabsorption ; Graphitrohr, pyrolyt. Graphit
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The lanthanoids were determined by furnace AAS. The influence of coating the graphite tube with pyrolytic graphite is discussed and standard conditions and detection limits (10−8 to 10−12 g absolute) are presented. Resemblance of atomization with flame AAS is discussed and a proposal as to its mechanism is given.
    Notes: Zusammenfassung Der Einfluß einer Beschichtung der Graphitröhre mit pyrolytischem Graphit wird diskutiert und Standardbedingungen sowie Nachweisgrenzen (10−8 bis 10−12 g abs.) werden angegeben. Die Ähnlichkeit der Atomisierung bei der Flammen-AAS wird erörtert und der mögliche Mechanismus dargestellt.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 46-46 
    ISSN: 1618-2650
    Keywords: Trenn. von Ionen, anorgan ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 46-47 
    ISSN: 1618-2650
    Keywords: Trenn. von Rhodium und Iridium ; Chromatographie, Dünnschicht ; Anionenaustausch
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 48-48 
    ISSN: 1618-2650
    Keywords: Trenn. von Äthyl-2,3-dioxobutyrat-2-arylhydrazonen ; Chromatographie, Dünnschicht ; Antineoplastica
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 106-107 
    ISSN: 1618-2650
    Keywords: Best. von Arsen, Selen in Körperflüssigkeiten, Geweben ; Spektralphotometrie, Atomabsorption ; Hydrid-methode
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 108-109 
    ISSN: 1618-2650
    Keywords: Best. von Blei in Blut ; Spektralphotometrie, Atomabsorption ; Graphitrohr
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 133-134 
    ISSN: 1618-2650
    Keywords: Analyse von Aminosäuren ; Chromatographie, Dünnschicht ; automat. F luorimetrie
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 144-145 
    ISSN: 1618-2650
    Keywords: Best. von Spurenelementen in Lebensmitteln ; Spektralphotometrie, Atomabsorption ; Graphitrohr, Richtigkeit
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 145-146 
    ISSN: 1618-2650
    Keywords: Best. von Schwermetallen, Blei in Fruchtsäften ; Spektralphotometrie, Atomabsorption ; flammenlos, Vergleich von Aufschlußverfahren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 157-157 
    ISSN: 1618-2650
    Keywords: Nachw. von Digitoxinmetaboliten in Harn ; Chromatographie, Dünnschicht ; Radio
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 289-291 
    ISSN: 1618-2650
    Keywords: Best. von Eisen in Wasser ; Spektralphotometrie, Atomabsorption ; hochreines Wasser, Anreicherung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Beside ionic impurities, DI water contains non-ionic compounds, which mainly consist of the oxyhydrates of the elements Fe, Ti, and Si present as colloids. This paper describes an analytical method for Fe, which is based on a simple enrichment by evaporation and the subsequent determination by flameless AAS. It is demonstrated that DI water systems, which are mainly based on coprecipitation and ion exchange, remove the Fe from the main water only to a small extent. The Fe content in DI water shows significant variations.
    Notes: Zusammenfassung Neben ionischen Bestandteilen enthält selbst hochreines Wasser auch nicht-ionische Komponenten, hauptsächlich Oxidhydrate der Elemente Ti, Fe und Si, die als Kolloide vorliegen. Die analytische Bestimmung des Eisens durch Eindampfen in einer einfachen Anordnung mit anschließender flammenloser AAS wird beschrieben. Es wird gezeigt, daß DI-Wasseranlagen, die heute zumeist noch nach dem Prinzip der Mitfällung und anschließendem Ionenaustausch arbeiten, nur begrenzt kolloidal vorliegendes Eisen entfernen und daß das Reinstwasser in seinem Fe-Gehalt stärkeren Schwankungen unterworfen ist.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 290 (1978), S. 369-371 
    ISSN: 1618-2650
    Keywords: Best. von Elementspuren in Chrom(III)-salzen ; Spektralphotometrie, Atomabsorption ; Anreicherung an Aktivkohle mit Hilfe von Hexamethylenammonium-hexamethylendithiocarbamidat
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Ein Verfahren wird beschrieben zur Anreicherung von 10 Elementen aus Chrom(III)-salzen durch nur einen Trennschritt. Als Reagens dient Hexamethylenammonium-hexamethylendithiocarbamidat; die Spurenverbindungen werden von Aktivkohle sorbiert. Nach Behandlung mit SalpetersÄure erhÄlt man eine praktisch chromfreie Lösung. Die Spuren werden durch Flammen-Atomabsorptionspektrometrie bestimmt.
    Notes: Summary A procedure is proposed for the enrichment of 10 elements from chromium(III) salts within only one separation step. Hexamethyleneammonium-hexamethylenedithiocarbamate is used as reagent and the trace compounds are sorbed on activated charcoal. Treatment with nitric acid yields a solution which is practically free from chromium. The traces are determined by flame atomic-absorption spectrometry.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 293 (1978), S. 138-140 
    ISSN: 1618-2650
    Keywords: Best. von Mycotoxinen, Citrinin, Ochratoxin A, Aflatoxin M1, Penicillinsäure ; Chromatographie, Dünnschicht ; Graukeil
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Spots of citrinin, ochratoxin A, aflatoxin M1 and penicillic acid on thin-layer chromatograms can be semi-quantitatively estimated by using a grey scale, commonly used in photo laboratories. The detection limits are 0.01 μg for citrinin, 0.006 μg for ochratoxin A, 0.002 μg for aflatoxin M1 and 0.01 μg for penicillic acid. Standard curves for these mycotoxins are given.
    Notes: Zusammenfassung Mit Hilfe eines in Photolabors gebräuchlichen Graukeils können dünnschicht-chromatographische Flecke der obengenannten Mycotoxine halbquantitativ bestimmt werden. Die Nachweisgrenzen betragen 0,01 μg für Citrinin, 0,006 μg für Ochratoxin A, 0,002 μg für Aflatoxin M1 und 0,01 μg für Penicillinsäure. Eichkurven werden angegeben.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 291 (1978), S. 128-128 
    ISSN: 1618-2650
    Keywords: Best. von Blei in Fruchtsäften ; Spektralphotometrie, Atomabsorption ; Konzentrierung mit immobil. ED3A
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 291 (1978), S. 221-221 
    ISSN: 1618-2650
    Keywords: Trenn. von Aminen, aromat. ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 77
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 291 (1978), S. 224-224 
    ISSN: 1618-2650
    Keywords: Nachw. von Mercaptothiazolyl-benzothiazolen ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 78
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 293 (1978), S. 410-411 
    ISSN: 1618-2650
    Keywords: Best. von Beryllium in extraterrestrischer Materie ; Spektralphotometrie, Atomabsorption ; Graphitrohrküvette
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 79
    ISSN: 1618-2650
    Keywords: Trenn. von Seltenen Erden von Uran ; Photometrie ; Chromatographie, Dünnschicht ; Diäthyläther/Tetrahydrofuran/Bis-(2-äthylhexylphosphat)/HNO3
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Mit dem Laufmittel Diäthyläther/Bis-(2-äthylhexylphosphat) (HDEHP)/Salpetersäure (100∶1∶3,5) können alle Seltenen Erden (S.E.) dünnschicht-chromatographisch (DC-Trennung) getrennt werden. Durch Variation von HDEHP und HNO3 ist es möglich, entweder die Rf-Werte der schweren oder leichten S.E. auseinander zu ziehen. Eine weitere DC-Trennung der S.E. gelingt mit dem Laufmittel Diäthyläther/Tetrahydrofuran/HDEHP/ HNO3. Nach der DC-Trennung werden die einzelnen S.E. auf zwei Wegen quantitativ bestimmt: a) Durch Auswertung der Fleckengröße, b) photometrisch nach Abkratzen der Flecken mit Neothorin. Als Analysen-Beispiel wird die Bestimmung von S.E. im ppm-Bereich in Spilitischem Schalstein gezeigt. Die relativen Standardabweichungen sind befriedigend.
    Notes: Summary All rare earths can be separated by TLC with the eluent diethyl ether/bis-(2-ethylhexylphosphate) (HDEHP)/nitric acid (100∶1∶3.5). It is possible to increase the R f-differences between either the heavy or the light rare earths by variation of HDEHP and HNO3. A further separation can be obtained by using diethyl ether/THF/HDEHP/HNO3 as an eluent. After TLC separation the rare earths can be determined quantitatively in two ways: (a) by evaluation of spot area, (b) by photometry with Neothorin as indicator after scraping the spots. The determination of rare earths in the ppm range in spilites is shown as an example. The relative standard deviations are satisfactory.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 80
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 292 (1978), S. 213-215 
    ISSN: 1618-2650
    Keywords: Verwendung von Chelatationsionenaustauschern zur Spurenanalyse ; Gele mit Hydroxychinolin. Best. von Kobalt, Eisen, Mangan, Nickel, Blei, Uran ; Spektralphotometrie, Atomabsorption ; Glykolmethacrylatgel
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Sorption wird bei einem Probelösung/Sorbens-Verhältnis von 103 ml/g ausgeführt, wozu die einfachste experimentelle Technik benutzt wird: 1 h Schütteln, Dekantieren, Zentrifugieren. Hohe Konzentrationen von Ammonium-, Alkali- und Erdalkalisalzen stören nicht. Mit Ausnahme von Co können alle gebundenen Metalle reversibel mit kleinen Säurevolumina statisch oder dynamisch eluiert werden. Die quantitativen Bestimmungen werden spektralphotometrisch (U) oder mit Hilfe der Atomabsorption (Co, Fe, Mn, Ni, Pb) ausgeführt.
    Notes: Summary The sorption is performed at a sample-sorbent ratio of 103 ml/g using the simplest experimental technique: shaking for 1 h, decantation, centrifugation. High concentrations of ammonium, alkali and alkaline earth salts do not interfere. All bound metals, except Co, can be reversibly eluted by small acid volumes in a batch or from a column. The eluted metals are quantitatively determined by spectrophotometry (U) or atomic absorption (Co, Fe, Mn, Ni, Pb).
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 81
    ISSN: 1618-2650
    Keywords: Analyse von Prostaglandinen, Thromboxan, Prostaglandinendoperoxiden, 12-Hydroxyeicosantetraensäure, 12-Hydroxyheptadecatriensäure aus Thrombocyten ; Chromatographie, Dünnschicht ; gebildet aus Arachidonsäure, radiochemisch
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A three-step thin-layer chromatographic procedure is described for the isolation and measurement of the various compounds formed by human platelets from radioactive arachidonic acid. The data presented show that other unknown compounds may also be formed in substantial amounts. The method can be used on a routine basis by combining a two-dimensional thin-layer chromatographic separation with an additional TLC for a complete resolution of the prostaglandins and other products.
    Notes: Zusammenfassung Ein dreistufiges TLC-Verfahren wird beschrieben zur Trennung und Bestimmung der verschiedenen Verbindungen, die durch Thrombocyten aus radioaktiver Arachidonsäure gebildet werden. Die vorliegenden Ergebnisse zeigen, daß außer den oben genannten noch weitere unbekannte Verbindungen in wesentlichen Mengen gebildet werden können. Durch Kombination einer dreidimensionalen TLC mit einer weiteren TLC-Trennung kann eine vollständige, routinemäßige Analyse der Prostaglandine und anderen Verbindungen durchgeführt werden.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 82
    ISSN: 1618-2650
    Keywords: Spektralphotometrie, Atomabsorption ; Methanpyrolyse zur Behandlung des Graphitrohr-Atomisators
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 83
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 283 (1977), S. 9-14 
    ISSN: 1618-2650
    Keywords: Spektralphotometrie, Atomabsorption ; flammenlos, Störungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary In the first part different methods for studying interferences of the time dependent signal in flameless AAS are presented with emphasis on factorial designs in experimentation as opposed to the one-factor-at-a-time approach. An example of the statistical computations necessary for interpretation of a multifactor experiment is worked out and discussed in detail with special consideration of the explanation of first-order interactions. The influence of instrumentation upon determinations in the graphite furnace is dealt with in the second part: The temperature in the graphite furnace was measured with a pyrometer, a thermocouple and a Hg-thermometer. The results obtained with the pyrometer were in good agreement with the values given by the manufacturer. The stability of the AAS system was checked and found to be sufficient for the investigation of interferences.
    Notes: Zusammenfassung Im ersten Abschnitt werden die verschiedenen Möglichkeiten zur Untersuchung von Störungen des zeitabhängigen Signals bei der flammenlosen AAS aufgezeigt, wobei besondere Bedeutung den faktoriellen Versuchsplänen im Gegensatz zu einparametrigen Untersuchungen beigemessen wird. Ein Beispiel der statistischen Auswertung zur Interpretation eines Experiments mit mehreren Faktoren wird gebracht, und dabei besonderes Gewicht auf die Erklärung von Wechselwirkungen zwischen zwei Faktoren gelegt. Im zweiten Abschnitt werden die apparativen Einflüsse auf Messungen in der Graphitrohrküvette behandelt. Dazu wurde die Temperatur im Graphitrohr mit einem Pyrometer, einem Thermoelement und einem Quecksilberthermometer gemessen. Die Temperaturen, die mit der pyrometrischen Methode gefunden wurden, stimmen gut mit den vom Hersteller angegebenen Werten überein. Die Stabilität des AAS-Gerätes wurde überprüft: sie reicht für die Durchführung von Interferenzstudien aus.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 84
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 283 (1977), S. 32-32 
    ISSN: 1618-2650
    Keywords: Nachw. von LSD, Ergot-Alkaloiden ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 85
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 283 (1977), S. 97-103 
    ISSN: 1618-2650
    Keywords: Best. von Cadmium ; Spektralphotometrie, Atomabsorption ; flammenlos, Störungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Interferences in the flameless determination of cadmium using the HGA 72 were studied for HCl, HNO3, H2SO4, HClO4 and HF and found to be depending on different thermal pretreatment. The interferences of cations were much smaller than for anions. The results are discussed with respect to thermal stability as well as atomization rate of the compositions under investigation. Special emphasis is put upon the presence of interactions between interferents, which in some cases can be used to eliminate interferences.
    Notes: Zusammenfassung Interferenzen, die bei der flammenlosen Bestimmung von Cadmium in der HGA 72 auftreten, wurden bei HCl, HNO3, H2SO4, H3PO4, HClO4 und HF studiert; die AbhÄngigkeit ihres Auftretens von der thermischen Vorbehandlung wird gezeigt. Interferenzen von Kationen sind kleiner. Die Ergebnisse werden im Hinblick auf die thermische StabilitÄt und die Atomisierungsgeschwindigkeit der Proben diskutiert. Besonders betont wird die Gegenwart von Wechselwirkungen zwischen Störungen, die manchmal auch benützt werden können, um Interferenzen auszuschalten.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 86
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 283 (1977), S. 183-190 
    ISSN: 1618-2650
    Keywords: Best. von Blei ; Spektralphotometrie, Atomabsorption ; flammenlos, Störungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Interferences in the flameless determination of lead using the HGA 72 were studied for HCl, HNO3, H2SO4, H3PO4, HClO4, HF and for a number of cations. In certain instances interferents in just 1000-fold concentration over lead are shown to cause deviations in the lead signal. Many of the interferences are matrix-dependent themselves and can be reduced by matrix variations. Optimization of the thermal pretreatment can be used effectively to reduce random error and/or systematic errors. The thermal stability of lead compounds in the graphite furnace was sufficient for charring procedures up to 900° C for 20 s.
    Notes: Zusammenfassung Interferenzen, die bei der flammenlosen Bestimmung von Blei in der HGA 72 auftreten, wurden bei HCl, HNO3, H2SO4, H3PO4, HClO4, HF und einigen Kationen studiert. In gewissen Fällen reicht ein nur 1000 facher Überschuß des Störions, um Abweichungen vom Signal des Bleistandards hervorzurufen. Da das Auftreten von Interferenzen auch oft matrixabhängig ist, können Matrixvariationen zur Unterdrückung von Interferenzen eingesetzt werden. Die Optimierung des Temperaturprogrammes wird erfolgreich zur Beeinflussung des Zufallsfehlers und/ oder systematischer Fehler herangezogen. In der Graphitrohrküvette reichte die Stabilität der Bleiverbindung aus, um beim Veraschungsschritt die Temperatur bis auf 900° C (20 s) zu steigern.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 87
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 283 (1977), S. 337-341 
    ISSN: 1618-2650
    Keywords: Best. von Quecksilber in Luft, Gasen ; Spektralphotometrie, Atomabsorption ; flammenlos
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Mercury is adsorbed on cellulose powder and activated charcoal. The contents of the adsorber are burnt in the oxy-hydrogen flame, and the mercury determined by the flameless atomic absorption procedure. The method is applicable to mercury present as metallic vapour, organo mercurical compounds and particulate matter containing adsorbed mercury compounds. The combustion step eliminates all possible non-atomic absorption interferences in the measuring procedure and ensures quantitative recovery of the mercury from the adsorption material. Quantitative adsorption recovery over a wide range of flow rate from 2–200 l/h allows the use of small battery operated pumps for personal monitoring, or vacuum pumps for high speed and large volume sampling. The range of flow rate makes isokinetic sampling conditions possible.
    Notes: Zusammenfassung Quecksilber wird an Cellulosepulver und Aktivkohle adsorbiert. Der Inhalt des Adsorbers wird in der Wasserstoff-Sauerstoff-Flamme verbrannt und das Quecksilber durch flammenlose Atomabsorption bestimmt. Die Methode erfa\t Quecksilber als Metalldampf, in Form von Organo-Quecksilberverbindungen sowie Quecksilberverbindungen, die an Staubpartikel adsorbiert sind. Die Verbrennung in der Wasserstoff-Sauerstoff-Flamme eliminiert Störungen durch nicht-atomare Absorption bei der AAS-Messung und garantiert die quantitative Erfassung des adsorbierten Quecksilbers. Die quantitative Adsorption über einen gro\en Bereich der Durchflu\geschwindigkeit von 2–200 l/h erlaubt batteriebetriebene Pumpen für die Quecksilbermessung „am Mann“, oder den Einsatz von Vakuumpumpen für die Probenahme bei hoher Durchflu\rate und gro\em Probenvolumen. Der gro\e Bereich der Durchflu\rate gestattet isokinetische Bedingungen für die Probenahme.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 88
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 284 (1977), S. 47-48 
    ISSN: 1618-2650
    Keywords: Analyse von Ergotalkaloiden ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 89
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 285 (1977), S. 48-48 
    ISSN: 1618-2650
    Keywords: Nachw., Best. von Dichlorvos in Biolog. Material ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 90
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 285 (1977), S. 255-255 
    ISSN: 1618-2650
    Keywords: Trenn. von Thiazolylbenzothiazolen ; Chromatographie, Dünnschicht ; isomere
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 91
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 286 (1977), S. 50-53 
    ISSN: 1618-2650
    Keywords: Trenn, von Seltenen Erden ; Chromatographie, Dünnschicht ; Verteilungsverfahren ; Tetrahydrofuran, Triphenylphosphinoxid, Paraldehyd, Di-iso-propyläther-Tetrahydrofuran
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Verteilungskonstanten von Selten-Erd-Nitraten im System Tributylphosphat-wäßrige Nitrat-Lösung werden berechnet. Dünnschicht-chromatographisch können mit Tributylphosphat in Isooctan als Laufmittel die Selten-Erd-Nitrate von La bis Gd vom Gd bis Lu getrennt werden. Eine Trennung von 13 Seltenen Erden auf einem Chromatogramm gelingt mit den Laufmitteln a) Tetrahydrofuran/Paraldehyd/Salpetersäure (20∶70∶10), b) dem Laufmittel Triphenylphosphinoxid (0,3 M in Paraldehyd) und konz. Salpetersäure im Verhältnis 90∶10, c) Di-iso-propyläther/Tetrahydrofuran/Salpetersäure (100 ∶ 60 ∶ 10). Der Trennmechanismus wird diskutiert.
    Notes: Abstract The distribution constants of the rare earth nitrates in the system tri-n-butylphosphate/aqueous nitrate solution are calculated. With thin-layer chromatography it is possible to separate the rare earth nitrates from La to Gd and from Gd to Lu in the solvent system tri-n-butylphosphate in i-octane. A separation of 13 rare earths in only one chromatogram is possible in the solvent systems a) tetrahydrofuran/paraldehyde/nitric acid (20∶70∶10), b) tri-phenylphosphinoxide (0.3 M in paraldehyde)/conc. nitric acid in the ratio 90∶10, c) di-iso-propylether/tetrahydrofuran/nitric acid (100∶60∶10). The mechanism of the separation is discussed.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 92
    ISSN: 1618-2650
    Keywords: Best. von Kupfer in Legierungen, Stahl ; Spektralphotometrie, Atomabsorption ; Graphitrohrküvette, Spuren
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Bestimmung kleiner und kleinster Kupfergehalte in Stahl und anderen Metallegierungen durch Atomabsorptions-Spektralphotometrie wurde untersucht. Dabei konnte festgestellt werden, daß die bei Untersuchungen an wäßrigen Lösungen mit der Flamme auftretenden merklichen Interferenzen durch Begleitelemente völlig ausgeschaltet werden können, wenn das Kupfer mit Pb-DDTC in Chloroform extrahiert und der Extrakt mit der Graphitrohrküvette untersucht wird. Ferner wurde festgestellt, daß die Graphitrohrküvette der Flamme bei den Arbeiten mit organischen Lösungsmitteln erheblich überlegen ist, da von der Art der Lösungsmittel keine Einschränkung des Einsatzbereiches erfolgt. — Die Methoden der kontinuierlichen Veränderungen nach Job und des molaren Verhältnisses nach Yoe u. Jones zur Bestimmung der Komplexzusammensetzung konnten für das System Cu-DDTC auf das Arbeiten mit der Graphitrohrküvette übertragen werden.
    Notes: Abstract The determination of small and smallest amounts of copper in steel and other metal alloys by atomic absorption spectroscopy was investigated. It has been found, that the interferences caused by accompanying elements in the determination in aqueous solution with the flame can be completely removed by extracting the copper with Pb-DDTC in chloroform and determining this extract with the heated graphite atomizer. Moreover, it was recognised, that working with the heated graphite atomizer in organic solutions shows great advantages compared with the flame, because any solvent may be used. The methods of continuous variation by Job and the molar ratio by Yoe and Jones for the determination of the complex stoichiometry were transferred to the system Cu-DDTC by working with the heated graphite atomizer.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 93
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 283 (1977), S. 15-21 
    ISSN: 1618-2650
    Keywords: Spurenanalyse ; Silberhalogenide als Spurenfänger für Chelatkomplexe ; Analyse von Mangan, Manganverbindungen ; Spektralphotometrie, Atomabsorption ; Komplexierung von Spuren mit Phenanthrolin, AgJ als Spurenfänger
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Das Nachweisvermögen der Flammen-AAS für Elementspuren wird in Gegenwart der Matrix Mangan erheblich herabgesetzt, so daß eine Abtrennung der Spuren bei der Reinheitskontrolle von Mangan und Manganverbindungen erforderlich ist. Dazu werden die Spuren mit 1,10-Phenanthrolin komplexiert und mit Silberjodid als Spurenfänger angereichert. Durch Erhitzen des abfiltrierten Silberjodids mit HNO3 gelangt man zu nahezu matrixfreien Spurenlösungen von 10 ml, in denen 9 Elemente (Fe, Co, Ni, Cu, Zn, Cd, Pb, Bi und Tl) durch Flammen-AAS bestimmt wurden. Bei Einwaagen von 5–10 g Mangan bzw. Manganverbindungen unterschiedlicher Oxidationsstufen werden — je nach Element — Nachweisgrenzen zwischen 0,01 und 1 ppm erreicht. Durch Aufkonzentrieren der Spurenlösung auf 1 ml und anschließende Bestimmung mit der „Injektionsmethode“ der Flammen-AAS gelangt man zu Nachweisgrenzen von 0,007–0,1 ppm.
    Notes: Abstract The power of detection of flame AAS for trace elements decreases considerably in presence of manganese. For the purity control of manganese and manganese compounds, therefore, it is necessary to separate the traces from the main component of the samples. For that purpose the traces were complexed by 1,10-phenanthroline and coprecipitated by silver iodide as trace collector. To receive a trace solution of 10 ml being free of manganese the filtered AgI was boiled with HNO3. The enriched elements (Fe, Co, Ni, Cu, Zn, Cd, Pb, Bi and Tl) were determined by flame AAS. Using samples of 5 to 10 g of manganese or manganese compounds of different stages of oxidation the limits of detection of the various elements were found to be in a range between 0.01 and 1 ppm. By evaporation of the trace solution down to 1 ml and determination of the traces by the “injection method” of flame AAS limits of detection are obtained between 0.007 and 0.1 ppm.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 94
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 283 (1977), S. 303-303 
    ISSN: 1618-2650
    Keywords: Best. von Blei in Boden ; Spektralphotometrie, Atomabsorption ; Matrixeinfluß
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 95
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 284 (1977), S. 19-21 
    ISSN: 1618-2650
    Keywords: Best. von Verunreinigungen in Phosphor ; Spektralphotometrie, Atomabsorption ; Trennungen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Nach Oxydation der Probe zu H3PO4 mit HNO3/HCl werden die Kationen an einem stark sauren Kationenaustauscher gebunden, mit HCl eluiert und durch AAS bestimmt. Von den häufigsten Verunreinigungen des reinen roten Phosphors werden die Alkali- und Erdalkalielemente sowie die meisten Schwermetalle erfaßt. Fe und As werden nicht abgetrennt, Al nur teilweise. Fe und Al werden durch Extraktion ihrer Oxinate isoliert. As wird aus HBr mit Benzol extrahiert und über die AsH3-Reaktion bestimmt.
    Notes: Abstract After oxidizing the sample to H3PO4 with HNO3/HCl, the cations are absorbed on a strong acid cation exchange resin. They are eluted with HCl and are determined by AAS. Under the most commonly found impurities of high-purity red phosphorus, the alkali and alkaline earth elements and most of the heavy metals can be separated. Fe and As are not separated, Al is partially separated. Fe and Al are isolated by extraction of their 8-quinolinol compounds. As is extracted from HBr with benzene and is determined by means of the AsH3-method.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 96
    ISSN: 1618-2650
    Keywords: Spektralphotometrie, Atomabsorption ; flammenlos, systemat. Fehlerquellen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird versucht, an Hand ausgewählter Elemente (Fe, Co, Ni, Ag und Cd) schwerwiegende systematische Fehler bei der Bestimmung durch flammenlose Atomabsorptionsspektrometrie aufzuzeigen und deren Ursache zu diskutieren. Neben den Parametern des Temperaturprogramms und des Schutzgasstroms ist die Art und Struktur des Graphits, sowie dessen Reaktivität von entscheidendem Einfluß auf Empfindlichkeit und Nachweisvermögen des Verfahrens. „Depressionen“ bei der Verwendung stark saurer Analysenlösungen werden bestätigt und es wird versucht, diese im Zusammenhang mit der Reaktivität von Graphit zu erklären. An einem vereinfachten Modell wird der Einfluß organischer Lösungsmittel bzw. organischer Lösungen von Komplexbildnern wie Dithizon, NH4-DDTC und APDC auf die Atomisierung untersucht. Es wird diskutiert, ob die dabei registrierten „Depressionen“ Verluste sind, die durch die Bildung flüchtiger metallorganischer Verbindungen bereits bei Temperaturen ab 500° C entstehen. Besonders schwerwiegend sind diese Verlustreaktionen bei Anwesenheit halogenierter Kohlenwasserstoffe, wie an Hand der Reaktionen von Fe, Cd, Co, Ni und Ag mit Chloroform gezeigt werden kann.
    Notes: Abstract With selected elements (Fe, Co, Ni, Ag and Cd), the serious systematic errors inherent in flameless atomic absorption spectrometry are demonstrated and their origins are discussed. Besides the parameters of the temperature program and the inert gas stream, the type and structure of the graphite, as well as its reactivity have a decisive influence on the sensitivities and limits of detection of the technique. Depression of the signal is observed with the use of strongly acid solutions and it has been attempted to explain this in connection with the reactivity of the graphite. The influence of organic solvents and organic solutions of complexes with dithizone, NH4-DDTC and APDC on the atomization have been investigated with simplified examples. It can be presumed that the resulting depression of the signal is due to losses by the formation of volatile metal-organic compounds at temperatures above 500° C. Particularly large are the losses in the presence of hydrocarbon halides as can be demonstrated by the reaction of Fe, Cd, Co, Ni, and Ag with chloroform.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 97
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 284 (1977), S. 41-41 
    ISSN: 1618-2650
    Keywords: Best, von Kupfer, Nickel, Kobalt in Geolog. Material ; Spektralphotometrie, Atomabsorption ; Extraktion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 98
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 285 (1977), S. 111-120 
    ISSN: 1618-2650
    Keywords: Chromatographie, Dünnschicht ; Steuergerät zur automatischen Registrierung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Ein Gerät zur vollautomatischen Steuerung eines DC-Spektralphotometers wurde entwickelt. Zusätzlich zur automatischen Registrierung aller Spuren eines Dünnschicht-Chromatogramms werden Remissionsminima erkannt und ihre Remissionsgrade und Ortskoordinaten ausgedruckt. Eine zweite Betriebsart ermöglicht ein manuelles Abrastern und Ausmessen eines Fleckes an jeder beliebigen Stelle der DC-Platte. Ein Rechneranschluß zur Auswertung der Meßergebnisse ist vorhanden. An Hand von Beispielen wird gezeigt, daß Reproduzierbarkeits- und Konzentrationsfehler bei der automatischen Registrierung strichförmiger Flecke wesentlich kleiner sind als bei Handpositionierung kreisförmiger Flecke. Die Linearität verschiedener Analysenfunktionen wird über 2 Zehnerpotenzen der Strichbelegung untersucht. Dabei erweist sich die Kubelka-Munk-Funktion in bezug auf Linearität allen anderen untersuchten Funktionen überlegen. Eine Kosten-Nutzen-Rechnung zeigt, daß in einem Routinelabor durch Einsatz eines Auftragegerätes und eines Steuergerätes für die automatische Registrierung trotz höherer Investitionskosten die Gesamtkosten einer Analyse um 70% gesenkt werden können.
    Notes: Abstract An instrument has been constructed for the automatic control of a TLC spectrophotometer. In addition to the automatic scanning of all tracks of a thin-layer chromatogram the positions and values of diffuse reflectance minima are recognized and printed. A second mode allows the manual scanning and measurement of a spot at any position on the TLC plate. A digital output is provided for the evaluation of the results with a computer. The errors of reproducibility and of concentration are much smaller using the automatic scanning of bands than using the manual positioning of circular spots as the examples show. The linearity of several analytical functions is analysed within two decades of concentration. The Kubelka-Munk function was found to be superior in linearity to all other functions studied. Calculations of costs show, that the total costs of an analysis in a routine laboratory can be lowered to an extend of about 70% by the use of an application instrument and a controlling instrument for automatic scanning inspite of the higher costs of investments.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 99
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 285 (1977), S. 270-270 
    ISSN: 1618-2650
    Keywords: Trenn. von Aryl-p-methoxybenzoylbenzofuranyl-thiosemicarbazonen, Contraceptiva ; Chromatographie, Dünnschicht
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 100
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 286 (1977), S. 95-99 
    ISSN: 1618-2650
    Keywords: Nachw. von Herbiciden ; Chromatographie, Dünnschicht ; Dansylierung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Die Reaktion von Dansylchlorid mit verschiedenen Herbiciden und Derivaten, die Aminogruppen enthalten oder zu Anilinen hydrolysierbar sind, wird beschrieben. Auf der Dünnschichtplatte lassen sich die fluorescierenden Stoffe gut trennen und identifizieren, was anhand von schematischen Darstellungen der Dünnschicht-Chromatogramme gezeigt wird.
    Notes: Abstract The reaction of dansyl chloride with various herbicides and derivatives containing amino groups or hydrolyzable to anilines is described. On TLC plates the fluorescent substances can be readily separated and identified as shown by diagrammatic representation of the thin-layer chromatograms.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...