ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (901)
  • Fisheries
  • 2020-2023
  • 1985-1989  (901)
  • 1985  (901)
Collection
Publisher
Years
  • 2020-2023
  • 1985-1989  (901)
Year
  • 11
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 436-439 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Capillary columns ; Large-volume injection onto capillary columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A modification of a packed GC injector to a capillary injector is presented using a simple device which is connected to the GC column by an adsorption-free connector. It permits injections of large sample volumes up to 500 μl hexane solutions on normal 0.3 mm i.d. capillary columns. No special requirements for the stationary phase are necessary. Involatile residues remain inside the device which can be exchanged easily. High performance of separation and quantification is achieved.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 456-458 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Fused silica and glass capillary columns ; Helium ionization detector ; Trace gas analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The capability of the helium ionization detector (HID) to operate in connection with capillary columns for trace gas analyses has been evaluated. Two different capillary columns were considered: a PLOT fused silica column with molecular sleve and a thick film WCOT glass column with PS-255. The determination of trace impurities in gases can be achieved with evident advantages over classical adsorption columns, even using a split injection system. Direct on-column injections also have been investigated with promising results.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 13
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Fused silica capillary columns ; Split-splitless injection ; Drinking water treatment ; Helogenated hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In this paper we report a way to evaluate the removal of volatile halogenated hydrocarbons formed after break-point chlorination in the Arno river raw water at the Mantignano Utility, Florence, Italy, following dechlorination by hydrogen peroxide. The removal evaluation is performed by GC-ECD on fused silica capillary columns with split-splitless injection on n-pentane extracts and by other analytical techniques such as UV254 absorption, TOC and TOX. Both laboratory and pilot plant data on Arno river raw water are reported and discussed.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 267-269 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Capillary columns ; Organic geochemistry ; Thermodesorption/cold trap injection ; Petroleum hydrocarbons in sedimentary rocks ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 15
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985) 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 16
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 283-289 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Fused silica capillary columns ; Microbial mutagenicity ; Solvent refined coal ; Creosote oils ; Polyaromatic hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The chemical composition of a commercially available creosote was compared to a direct coal liquefaction product, i.e., solvent refined coal-II fuel oil blend (SRC-II FOB) using high resolution gas chromatography (HRGC). In addition, hydrogenated products of these materials were studied. Samples were fractionated by chemical class on neutral alumina. Those fractions previously shown to be the most mutagenic and tumorigenic in laboratory bioassays of coal-derived materials were analyzed and compared by HRGC and gas chromatography/mass spectrometry (GC/MS). Individual components were tentatively identified and quantitated. Although similar chemical components were present in the creosote and SRC-II FOB fractions studied, the creosotes had higher concentrations of heavy molecular weight materials and a lower ratio of alkylated to parent polycyclic aromatic compounds than the coal liquefaction products. The creosote samples also had a significantly higher concentration of components which eluted in the polycyclic aromatic hydrocarbon (PAH) chemical class fraction. Amino-substituted PAH were present in both nonhydrogenated coal liquid and creosote materials. The creosote and SRC-II FOB crudes and nitrogen-containing polycyclic aromatic compound (NPAC) chemical class fractions expressed similar microbial mutagenicity. Based on chemical analysis data, the predicted tumorigenic potency of the creosote in laboratory bioassay systems would be equivalent to or greater than the SRC-II FOB.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 308-308 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 627-628 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 19
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Capillary columns ; Elution profiles ; Sorption effect ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The elution profiles observed with overloaded capillary columns are well described by a four-parameter theoretical model derived from the basic mass balance equations which relies on an expansion of the partition isotherm to the second term and takes the sorption effect into account. The reliability of the model is demonstrated by the fact that the peak leaning coefficient obtained from a least squares fit of the model to the experimental peak is in good agreement with that obtained from the variation of peak height with retention time at peak maximum. The coefficeint of apparent axial dispersion is independent of sample size and can be used to characterize the plate height at zero concentration of an overloaded capillary column.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 20
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 607-610 
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Temperature programmed retention indices ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Direct conversion of isothermal to temperature programmed indices is not possible. In this work it is shown that linear temperature programmed retention indices can only be calculated from isothermal retention data if the temperature dependence of both the distribution coefficients and the column dead time are taken into account.Procedures are described which allow calculation of retention temperatures and from these, accurate programmed retention indices. Within certain limits the initial oven temperature and programming rate can be chosen freely. The prerequisite for this calculation is the availability of reliable isothermal retention data (retention times, retention factors, relative retention times, or retention indices) at two different temperatures for one column.The use of compiled isothermal retention indices at two different temperatures for the calculation of retention temperatures and thus temperature programmed indices is demonstrated. For the column for which programmed retention indices have to be determined, the isothermal retention times of the n-alkanes and the column dead time as a function of temperature have to be known in addition to the compiled data for a given stationary phase.Once the programmed retention indices have been calculated for a given column the concept allows the calculation of temperature programmed indices for columns with different specifications. The characteristics which can be varied are: column length, column inner diameter, phase-ratio, initial oven temperature, and programming rate.
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...