ISSN:
1612-1112
Schlagwort(e):
Gas chromatography
;
Morpholine
;
Hydrazine
;
Boiler feed water and steam condensates
Quelle:
Springer Online Journal Archives 1860-2000
Thema:
Chemie und Pharmazie
Notizen:
Summary Hydrazine, an oxygen scavenger in boiler water, was derivatised to the corresponding acetone azine and determined at the ng ml−1 level by gas chromatography. Morpholine, a corrosion inhibitor used in steam boilers, was estimated either directly (if 〉2.0 μg ml−1) or by quantitative preconcentration (0.1 ng – 2.0 μg ml−1). To obtain symmetrical peaks for these amines, the column packing was coated with KOH. Use of a nitrogen-specific detector improved accuracy of estimation of hydrazine and morpholine, giving a RSD of 1.9–3.6%. Chromatographic analysis of these amines in boiler feed water and steam condensate samples collected from boilers servicing a petroleum refinery is described. Environmental safety regulations calls for monitoring of hydrazine and the methods developed can easily be adapted for this purpose.
Materialart:
Digitale Medien
URL:
http://dx.doi.org/10.1007/BF02269836