ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Springer  (19.840)
  • American Geophysical Union (AGU)
Sammlung
Erscheinungszeitraum
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Journal of radioanalytical and nuclear chemistry 215 (1997), S. 257-261 
    ISSN: 1588-2780
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie , Energietechnik
    Notizen: Abstract Neutrons from a source are moderated by means of hydrogenous materials such as polyethylene (PE) or water to reduce the energy of fast neutrons and to increase the fluence rate of moderated neutrons. The rise-time and γ-ray pulse height spectrum from a PE moderated241Am-Be neutron-gamma (n-γ) mixed source were measured by using6Li-BC501 scintillation detector and pulse shape discriminator (PSD) system. The difference in rise-time between γ and neutron signals tumed out to be 18.5 ns for the6Li-BC501 (n-γ) spectrometer system. The figure of merit (FOM) for this separation was estimated to be 1.52, and this was compared with the published results. From this comparison, the6Li-BC501 system has much superior characteristics in (n-γ) separation to other detector systems. Two Compton edges at around 1.87 and 3.99 MeV which are produced by H(n,γ)D reaction and by the first excited state of12C* from Be(α, n)12C* reaction were also investigated.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Journal of radioanalytical and nuclear chemistry 216 (1997), S. 75-79 
    ISSN: 1588-2780
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie , Energietechnik
    Notizen: Abstract The 1.369 MeV γ-rays emitted from24Na→24Mg+β−+γ after23Na(n,γ)24Na reaction were counted by high purity germanium (HPGe) detector and the half-life of24Na was derived. This process was simulated by Monte Carlo Neutron and Photon Transport Code (MCNP-4A).252Cf neutron source was moderated by a polyethylene (PE) cylinder to increase the cross section of neutron absorption reaction and to decrease the biological hazard. NaCl powder of 20 cm3 and 40 cm3 volume in cylindrical polypropylene capsules were irradiated by the neutrons passed through the moderator. MCNP-4A was used to determine the optimum size of PE moderator, to assume the realistic geometry of the HPGe detector, and to assume the absolute efficiencies of the detector. The count rates for 1.369 MeV γ-rays in the HPGe detector were calculated by MCNP-4A for 20 cm3 and 40 cm3 NaCl. The accumulated counts calculated tumed out to be higher than those actually measured by 31% with a relative error of 3%. The half-life of24Na measured within 4% and 1% for 20 cm3 and 40cm3 NaCl agrees with that of the reference. So, we can say that the result of MCNP-4A has about 30% of accuracy and 3% of precision in simulating the neutron activation analysis.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 1572-817X
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Elektrotechnik, Elektronik, Nachrichtentechnik , Physik
    Notizen: Abstract Data are presented on InGaAsP/InP planar buried heterostructure (PBH) distributed feedback (DFB) lasers operating at 1.3 μm. A four-step MOVPE process and holographic lithography are employed to fabricate these lasers. The CW laser threshold and the slope efficiency from these lasers are 9 mA and 0.23 mW mA-1 per facet at room temperature. Single-longitudinal-mode operation with side-mode suppression of more than 35 dB is obtained at 5 mW.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 1572-879X
    Schlagwort(e): synthetic clinoptilolite ; cobalt ; NO reduction ; CH4 ; zeolite pore structure
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Abstract Selective reduction of NO by CH4 in the presence of excess O2 has been studied on cobalt-ion-exchanged synthetic clinoptilolite (Co-CLI) zeolite. The catalytic results are compared with those obtained from Co-ZSM-5 and Co-FER, the two most widely studied catalysts for this reaction. At T ≥ 500 ºC, Co-CLI is much more active for NO reduction than Co-ZSM-5, but it is less active than Co-FER. However, it is found that the selectivity for CH4 toward reacting with NO at high temperatures (T ≥ 450 ºC) is higher on Co-CLI than on Co-ZSM-5 or Co-FER. On the basic of the overall catalytic results, the importance of zeolite pore size as a structural parameter influencing the activity of intrazeolitic Co2+ ions for NO reduction by CH4 is discussed.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    ISSN: 1573-4803
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Maschinenbau
    Notizen: Abstract The cross-section of multilayered Al0.5Ga0.5As/GaAs epitaxial structure was investigated by atomic force microscopy (AFM). For the first time, a 5% NaClO etchant was employed to discern each layer and a clear cross-sectional image of the multilayered epitaxial structure was obtained in less than 3 s etching time. The AFM image using 0.1 m HCl was poorer than that using 5% NaClO; this is attributed to the difference in etching selectivity between HCl and NaClO solution.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Springer
    Journal of materials science 12 (1993), S. 244-245 
    ISSN: 1573-4811
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Maschinenbau
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Springer
    Journal of materials science 31 (1996), S. 5805-5809 
    ISSN: 1573-4803
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Maschinenbau
    Notizen: Abstract The effect of atmosphere control on the sintering behaviour of TiB2-20 wt% Ni ceramics was investigated. Sintering was performed at 1700 °C for 1h with commercial TiB2 powders produced by the earbothermic reaction. Under a fixed single atmosphere such as vacuum or Ar, densification was limited and large pores remained. However, a sintered density above 99% of theoretical could be achieved by a two-step sintering procedure in which the atmosphere was changed from vacuum to Ar at 1600 °C during the heat-up with subsequent isothermal sintering being performed at 1700 °C for 1h. Qualitative considerations about these phenomena are discussed.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 40 (1992), S. 200-204 
    ISSN: 1741-0444
    Schlagwort(e): Tooth ; Root canal length ; Voltage difference ; Endodontic therapy ; Impedance ratio ; Clinical evaluation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract Electronic root canal length measurement devices have made it easier and faster to measure the root canal length of a tooth compared with the conventional radiographic method. Of these electronic apex locators, the frequency-dependent type features greater accuracy and convenience in operation. However, its accuracy is still influenced by the presence of blood and/or the various electrolytes used in root canal therapy. This study describes the development of a new frequency-dependent electronic apex locator featuring electrolyte compensation, utilising an impedance ratio and voltage difference technique to minimise the influence of electrolytes on the accuracy of root canal length measurement. The errors for distances from file tips to apical constrictions were determined in vivo with the device operating with electrolyte compensation. The measured lengths were compared with the true lengths of the extracted teeth determined using a microscope. The mean error was +0.14±0.27 mm, and 95.2% of the measurements were within the clinical tolerance of ±0.5 mm. It was also found that the degree of accuracy was not dependent on the size of the apical foramen (p=0.74).
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 38 (2000), S. 603-609 
    ISSN: 1741-0444
    Schlagwort(e): Femoral anteversion ; Rendering ; 3D imaging ; Measurement
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract Femoral neck anteversion is the torsion of the femoral head with reference to the distal femur. Conventional methods that use cross-sectional computed tomography (CT), magnetic resonance or ultrasound images to estimate femoral anteversion have met with several problems owing to the complex, three-dimensional (3D) structure of the femur. These problems include not only the difficulty of defining the direction of the femoral neck axis and condylar line but also the dependency upon patient positioning. In particular, the femoral neck axis, the direction of the femoral head, known as the major source of error, is difficult to determine from either a single or several two-dimensional (2D) cross-sectional images. A new method has been devised for the measurement of femoral anteversion using the 3D imaging technique. 3D reconstructed CT images from the femoral head and trochanter to the distal femur are used to measure the anteversion. It is necessary to remove the soft tissue from the CT images and extract just the bone part. Then, the femoral anteversion is measured from a computer-rendered femur image. The 3D imaging method is compared with both the conventional 2D method and the physical method using 20 dried femurs. For the physical method, which is used as a reference value, a special apparatus is devised. The average difference between the results of the physical method and those of the 2D CT method is 5.33°. The average difference between the results of the physical method and those of the 3D imaging method is 0.45°. Seventy-four patients, who suffer from toe-in-gait disease, are tested to compare the 3D imaging method with the conventional 2D CT method. The average difference between the 2D and 3D methods is 8.6°, and the standard is 7.43°. This method provides a very accurate and reliable measurement of femoral anteversion, as it is virtually equivalent to the direct measurement of bisected dried femur in vitro.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    Springer
    Journal of radioanalytical and nuclear chemistry 222 (1997), S. 253-255 
    ISSN: 1588-2780
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie , Energietechnik
    Notizen: Abstract The chromatographic separation of magnesium isotopes was investigated by chemical exchange with the recently synthesized 1-oxa-4,7,10,13-tetraazacyclopentadecane-4,7,10,13-tetramerrifield peptide resin [N4O·4M]. The capacity of the novel N4O-4 Merrifield ion exchanger was 1.0 meq/g dry resin. The heavier isotope26Mg concentrated in the resin phase, while the lighter isotopes24Mg, and25Mg are enriched in the fluid phase. The maximum separation factors α, for25Mg−26Mg and24Mg−26Mg were found to be 1.048 and 1.022, respectively, at 20.0±0.02 °C with 2.0 M ammonium chloride solution as an eluent.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...