ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 9 (1995), S. 1473-1473 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 7 (1993), S. 1151-1151 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 8 (1994), S. 432-434 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The electron ionization mass spectra obtained, on two types of GC/MS instrument, of an impurity peak in a sample of fluorotrichloroethene (1) were those of two different compounds, viz., the epoxide of 1 and trichloroacetyl fluoride. Confirmation of the latter structure was provided by evidence from infrared spectroscopy. A study, on both instruments, of the variation of injector, source and interface temperatures has shown that the sample impurity is actually the epoxide which, at sufficiently high interface-region temperatures, can be converted to the acyl fluoride species. Ab initio molecular orbital calculations have confirmed that the acyl fluoride is more stable than the epoxide.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 2 (1988), S. 181-183 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 4 (1990), S. 436-439 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The introduction of more rigorous regulations aimed at controlling the use of sulphonated dyestuffs and dyestuff intermediates has pointed to the need for screening methods for the presence of these involatile compounds. Although much work has been caried out recently on the mass spectrometric behaviour of these compounds, it has been concerned principally with the production of molecular weight information using novel ionization methods rather than with any attempt to obtain structurally diagnostic fragment ions. In this mass spectrometric investigation of a range of naphthalene sulphonic acid salts, positive-ion and negative-ion fast-atom bombardment (FAB) mass spectra have been obtained and FAB-tandem mass spectrometry (MS/MS) has been used to acquire spectra (daugher-ion, parent-ion and neutral-loss) in an attempt to develop a useful screening method. On known compounds, best results were found when using a negative-ion neutral-loss scan to detect the loss of 64 mass units (corresponding to loss of SO2). This was confirmed by successful use of this scan to screen a sample of sulphonate residues.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 6 (1992), S. 269-271 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The design and use of an RF-only collision-cell ramp generator is described. The generatio controls the collision energy voltage applied to the RF-only collision cell in a hybrid mass spectrometer of BEqQ geometry. The generator enables the collision-cell voltage to be increased or decreased in a linear ramp, over the full 500 V available. The start/stop functions of the ramp are synchronized under data system control to the scan of the quadrupole mass analyser. The collision-induced dissociation spectra so produced show an increase in the product ion abundance.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 6 (1992), S. 608-615 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The results of thin layer chromatography/mass spectrometry (TLC/MS) and thin layer chromatography/tandem mass spectrometry (TLC/MS/MS) experiments are described. Spectra from the analytes were obtained directly from the absorbent without the need for extraction prior to analysis by mass spectrometry. These results illustrate the added specificity that the tandem mass spectrometer can afford in the detection and characterization of a range of compounds separated by TLC.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1076-5174
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The non-ester silicon-containing pyrethroid SSI-116 and its carbon analogue (ethofenprox, MTI-500) were investigated using a tandem quadrupole mass spectrometer incorporating a hexapole collision cell under positive-ion electron impact ionization conditions. Conventional mass spectrometry using the first quadrupole analyser only and tandem mass spectrometry on selected precursor ions and product ions, and also constant neutral loss scan experiments, were used. Accurate mass measurements on key ions were made using a high-resolution double-focusing mass spectrometer. Based on the experimental observations, mechanisms have been proposed to explain the major fragmentation pathways of SSI-116 and ethofenprox. The novel expulsion of silaethene, CH2=SiH2, as a neutral species from the silicon-containing insecticide and the formation of an ion at m/z 135, isomeric with the fragment ion, [C9H11O]+, observed in the spectrum of its carbon analogue, have also been rationalized. Minor fragmentation pathways, found only in the silicon-containing analogue, are also discussed.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 1985-10-11
    Description: A new, competitive, nonpeptide cholecystokinin (CCK) antagonist, asperlicin, was isolated from the fungus Aspergillus alliaceus. The compound has 300 to 400 times the affinity for pancreatic, ileal, and gallbladder CCK receptors than proglumide, a standard agent of this class. Moreover, asperlicin is highly selective for peripheral CCK receptors relative to brain CCK and gastrin receptors. Since asperlicin also exhibits long-lasting CCK antagonist activity in vivo, it should provide a valuable tool for investigating the physiological and pharmacological actions of CCK.〈br /〉〈span class="detail_caption"〉Notes: 〈/span〉Chang, R S -- Lotti, V J -- Monaghan, R L -- Birnbaum, J -- Stapley, E O -- Goetz, M A -- Albers-Schonberg, G -- Patchett, A A -- Liesch, J M -- Hensens, O D -- New York, N.Y. -- Science. 1985 Oct 11;230(4722):177-9.〈br /〉〈span class="detail_caption"〉Record origin:〈/span〉 〈a href="http://www.ncbi.nlm.nih.gov/pubmed/2994227" target="_blank"〉PubMed〈/a〉
    Keywords: Animals ; Aspergillus/*metabolism ; Benzodiazepinones/*isolation & purification/pharmacology ; Chemical Phenomena ; Chemistry ; Cholecystokinin/*antagonists & inhibitors/pharmacology/physiology ; Dose-Response Relationship, Drug ; Gallbladder/drug effects ; Guinea Pigs ; Ileum/drug effects ; Pancreas/drug effects ; Rats ; Receptors, Cell Surface/drug effects ; Receptors, Cholecystokinin
    Print ISSN: 0036-8075
    Electronic ISSN: 1095-9203
    Topics: Biology , Chemistry and Pharmacology , Computer Science , Medicine , Natural Sciences in General , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...