ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Artikel  (3.597)
  • Wiley-Blackwell  (3.597)
  • Physik  (3.597)
Sammlung
  • Artikel  (3.597)
Erscheinungszeitraum
  • 1
    ISSN: 0142-2421
    Schlagwort(e): SIMS ; GaAs ; round-robin ; sensitivity factor ; Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Physik
    Notizen: Round-robin studies on relative sensitivity factors (RSFs) in secondary ion mass spectrometry (SIMS) were conducted using bulk GaAs samples uniformly doped with various impurity elements. A total of 31 laboratories participated in two round-robins. More than 30 sets of relative ion intensities were obtained for B, Si, Cr, Mn, Fe, Cu, Zn, In and Te in GaAs. The RSFs for both positive and negative ions were derived for several types of SIMS instruments. The effect of primary ion incident angle was examined using quadrupole-based instruments and found to be the determining factor of the instrumental dependence of RSF. © 1998 John Wiley & Sons, Ltd.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 0142-2421
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Physik
    Notizen: A matrix effect correction is required to improve the accuracy of quantitative AES analysis. The correction includes terms involving the atomic density (n), electron back-scattering factor (R) and electron escape depth (L). Many schemes have been proposed by various people for corrections of the R and L terms. However, up to now, there have been no systematic investigations of the correction accuracy of the proposed schemes. We have evaluated the correction accuracy, based on measured intensity data for Au—Cu alloys of different compositions. Comparison was made between the observed intensity ratio K (=Iunk/Istd) and the calculated intensity, ratio K′ (= C(nunk/nstd)(Runk/Rstd)(Lunk/Lstd)), where C and I represent the concentration and intensity, respectively. The superscripts ‘unk’ and ‘std’ denote that the parameters are for unknown and standard specimens, here the pure elements. If the correction works well, the error Er (= K′ — K)/(K) will become smaller. Evaluations were carried out on three schemes for the R correction and on seven schemes for the L correction using the Au 239 eV, Au 2024 eV and Cu 920 eV transitions. The root mean square (RMS) of the calculated errors showed several per cent for the best case and 20-30% for the worst case. The RMS error varied a few per cent between schemes for the R correction but it varied ∼30% for the L correction.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 16 (1990), S. 140-143 
    ISSN: 0142-2421
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Physik
    Notizen: The Japanese VAMAS-SCA working group is composed of 19 institutes. Three kind of Au—Cu alloys (Au 75 at.-%-Cu 25 at.-%, Au 50 at.-%-Cu 50 at.-%, Au 25 at.-%-Cu 75 at.-%) were prepared, and these specimens, pure Au and pure Cu were distributed to the members of the VAMAS-SCA working group. The surface concentrations of these alloys were calculated from the Auger peak amplitudes in two ways. One method used the published relative sensitivity factors, and the other used pure Au and Pure Cu as the standard materials. The mean values of the surface concentrations calculated with the published relative sensitivity factors were almost the same as those calculated with the standard materials. This means that the published relative sensitivity factors are reliable to some extent. The error of the surface concentration calculated with pure Au and pure Cu as the standard materials lay between about 3% and 10%, and that with the relative sensitivity factors lay between about 7% and 20%. The calculated surface concentrations of Au were larger than the bulk concentrations of Au when the matrix effect was neglected.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    ISSN: 0142-2421
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Physik
    Notizen: The Japanese VAMAS-SCA working group is composed of 19 institutes. Three kinds of Au-Cu alloys (Au25 at%-Cu75 at%, Au50 at%-Cu50 at%, Au75 at%-Cu25 at%) were prepared, and these specimens were distributed to the members of Japanese VAMAS-SCA working group and Auger peak amplitude ratios were measured to clarify the correlation factor of different types of spectrometers. The comparison was carried out by using the relative sensitivity factor for Au and Cu. The relative sensitivity factor for lower energy varied from spectrometer to spectrometer, but that for higher energy did not vary so much. Therefore, to carry out the inter-laboratory comparison of the data, the transfer of the data of peak amplitude at higher energy should be recommended.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Chichester [u.a.] : Wiley-Blackwell
    Journal of Raman Spectroscopy 24 (1993), S. 179-181 
    ISSN: 0377-0486
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Physik
    Notizen: Good-quality high-Tc YBa2Cu3O7-x thin films deposited by the laser ablation method were investigated by Raman spectrosocpy. The vibrational spectra of thin films of YBa2Cu3O7-x at various laser intensities and with different polarizations were measured. The Raman modes change on increasing the laser power and in general such changes are reversible. However, as the laser intensity is increased above a certain value, dramatic changes occur in the Raman peaks, as a result of damage to the sample.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    New York : Wiley-Blackwell
    Journal of Polymer Science Part A-2: Polymer Physics 7 (1969), S. 889-896 
    ISSN: 0449-2978
    Schlagwort(e): Physics ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Physik
    Notizen: It is demonstrated that in a filled polymer the thermal stresses resulting from the difference in the thermal expansion coefficients of the filler and the polymer have significant effect on the apparent coefficient of thermal expansion of the composite. A model is constructed to aid the thermal stress analysis, and the results are found to agree well with the experimental data obtained from other sources. An expression for the apparent densities of filled polymers is also obtained but the agreement between the present prediction with an existing test result is found to be only qualitative.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    New York : Wiley-Blackwell
    Journal of Polymer Science Part A-2: Polymer Physics 7 (1969), S. 879-887 
    ISSN: 0449-2978
    Schlagwort(e): Physics ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Physik
    Notizen: The Fickian diffusion coefficient of methylene chloride in a glassy epoxy polymer is calculated with the use of Crank's model of discontinuous change of D with concentration C. The diffusion constant is obtained as 1.93 × 10-6 cm2/sec. The swollen layer behind the advancing solvent front is essentially in the rubbery state of the same polymer. The case II swelling by benzene is discussed in terms of a convective transport arising from the partial stress (internal) tensor of the penetrant. The superposition of Fickian and case II diffusion found with mixtures of methylene chloride and benzene is also discussed briefly.
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 36 (1988), S. 1731-1739 
    ISSN: 0021-8995
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: Semicrystalline LaRC-TPI is known to be capable of recrystallizing to higher melting crystalline forms upon initial melting. The behavior of these different crystalline forms has not been studied before. The present study uses techniques of differential scanning calorimetry and X-ray diffractometry to investigate thes crystalline structural changes during recrystallization of this material. Semicrystalline LaRC-TPIs synthesized from three different laboratories are included in this work.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 35 (1995), S. 1261-1271 
    ISSN: 0032-3888
    Schlagwort(e): Chemistry ; Chemical Engineering
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: This study clarifies and quantifies factors which increase the ductility of a low-molecular-weight propylene homopolymer having an intrinsic viscosity of 0.89 dl/g. The tensile behavior of homopolymer/ethylene-propylene rubber (EPR) blends was studied from the viewpoint of the associated molecular structure of EPR and its compatibility with the homopolymer. When EPR is “dissolved” in a homopolymer, the glass transition temperature (Tg) of the amorphous phase of a homopolymer was found to shift to a lower temperature, with homopolymer/EPR compatibility being subsequently evaluated using this shift, i.e., Δtg. Results show two conditions are required to improve the ductility of the low-molecular weight propylene homopolymer: ΔTg must be ≥ 3°C and ≥ 30 wt% EPR must be blended with the homopolymer.
    Zusätzliches Material: 18 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 24 (1986), S. 121-131 
    ISSN: 0887-6266
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Physik
    Notizen: The precise pressure dependence of apparent diffusion and permeation coefficients was measured by using a microcomputer system for collecting and treating permeation data for CO2 in glassy poly(ethylene terephthalate) below 1 atm between 15 and 40°C. The partial immobilization model was used to determine the dual-mode sorption and mobility parameters. The curves calculated with these parameters were in excellent agreement with experimental data. These parameters were also compared with sorption parameters obtained from measurements at 30°C. There was a small difference between the values of the parameters obtained from these permeation data and those from sorption data which we had previously obtained. Relations between this difference and the method of determination of the parameters are discussed.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...