Publication Date:
2013-08-31
Description:
Leakage currents were experimentally measured in PV modules undergoing natural aging outdoors, and in PV modules undergoing accelerated aging in laboratory environmental chambers. The significant contributors to module leakage current were identified with a long range goal to develop techniques to reduce or stop module leakage currents. For outdoor aging in general, module leakage current is relatively insensitive to temperature fluctuations, but is very sensitive to moisture effects such as dew, precipitation, and fluctuations in relative humidity. Comparing ethylene vinyl acetate (EVA) and polyvinyl butyral (PVB), module leakage currents are much higher in PVB as compared to EVA for all environmental conditions investigated. Leakage currents proceed in series along two paths, bulk conduction followed by interfacial (surfaces) conduction.
Keywords:
ENERGY PRODUCTION AND CONVERSION
Type:
Proceedings of the 26th Project Integration Meeting; p 629-645
Format:
application/pdf
Permalink