ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Polymer and Materials Science  (22)
  • Analytical Chemistry and Spectroscopy  (18)
  • 1985-1989  (40)
  • 1
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Using fast atom bombardment (FAB) ionization combined with tandem mass spectrometry (MS/MS), the identity of arsenobetaine (AB) in extracts of sole, haddock, lobster and shrimp was unequivocally confirmed. Evidence was also presented for the presence of arsenocholine (AC) in the shrimp extract. Confirmation was obtained by comparing the collision-induced dissociation (CID) daughter ion and parent ion spectra of major ions in the FAB spectra from these extracts with those from the authentic standards.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Letters Edition 25 (1987), S. 359-360 
    ISSN: 0887-6258
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Letters Edition 25 (1987), S. 267-267 
    ISSN: 0887-6258
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 15 (1988), S. 615-621 
    ISSN: 0887-6134
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The collisionally activated decomposition of [M + H]+ ions, generated by fast atom bombardment (FAB) of glutathione conjugates, has been studied by tandem mass spectrometry (MS/MS) using hybrid sector/quadrupole instruments. Abundant fragments of diagnostic utility were present in the daughter ion spectra. Common fragmentation modes were observed but their relative importance was strongly dependent on the nature of the conjugated species. As an example of a general approach to the characterization of glutathione conjugates in biological samples, the acetaminophen-glutathione conjugate was identified in rat bile, following coadministration of (2H0)- and (2H3)acetaminophen, using the experimental sequence: (i) conventional FAB mass spectrometric analysis, (ii) MS/MS using constant neutral loss (129 u) scanning to identify parent ions corresponding to glutathione conjugates, (iii) MS/MS to yield daughter ion spectra of parents so identified and corresponding to (2H0)- and (2H3)-labeled conjugates.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 10 (1987), S. 477-478 
    ISSN: 0935-6304
    Keywords: Capillary SFC ; Reproducibility ; Pump filling method ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0935-6304
    Keywords: Gas chromatography, GC ; Fused silica capillary columns ; Retention index ; Internal standards ; Environmental samples ; Dichlorobenzyl alkyl ethers ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A homologous series of 2,4-dichlorobenzyl alkyl ethers (DCBEs) have been synthesized and purified for use as retention index calibrants and internal standards. They are stable, sensitive to ECD and FID and ideal for GC-MS, with base peaks at m/z 159/161. The retention index calibration against the n-alkanes for a linear temperature program (LTP) series is given and recommendations made for the most suitable members of the DCBE series for use as internal standards in organochlorine (OC) residue analysis.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 12 (1985), S. 139-141 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Analysis for oestradiol bis-tert-butyldimethylsilyl ether by gas chromatography/mass spectrometry (GC/MS) with selected reaction monitoring ([M]+. → [M-C4H9]+) using a tandem double-focusing/quadrupole instrument gave a detection limit below 10 pg. During analyses of a plasma extract, the selectivity of detection was superior to conventional selected ion monitoring. A parent ion resolution of 5000 was used to eliminate detection of all components but the chosen analyte.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 35 (1988), S. 1945-1953 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: A polytheylene composite was prepared and tested. It was consisted of a high-density polyethylene (HDPE) matrix and uniaxial gel-spun high-modulus PE fiber. Aided by the similarity between matrix and fiber, transcrystallization of HDPE melt on the PE fiber surface was generated. Nucleating agents were not employed. The transcrystalline growth of HDPE on the PE fiber surface was found to consist of an inner and an outer zone. The inner zone, 2-3 μm thick, is composed of HDPE crystals nucleated on the PE fiber surface. Photomicrographs showed a well-defined region of row-nucleated HDPE on the surface of PE fiber. This means the fibrils of HDPE were found to grow out from the PE fiber axis and HDPE crystallites are oriented in planes perpendicular to the PE fiber axis. The fiber in the composite induced the transcrystalline growth of HDPE on the PE fiber surface at higher temperature than on cooling the melt. For 36 wt% fiber, the increase was 2.5°C, also resulting in ∼ 10% more crystals. Crystallization of a composite with 50 wt% fiber at 124°C involved two steps: The first a fast transcrystallization of HDPE on the PE fiber surface followed by the bulk crystallization of the HDPE.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 30 (1985), S. 741-753 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Three low density polyethylenes, one long branched (A) and two linear (B and C), have been solid-state-extruded at several constant temperatures from ambient to 80°C and to draw ratios ≤ 8. The initial densities and melt indices of A, B, and C are 0.920, 0.920, and 0.935 g/cm3, and 1.9, 0.8, and 1.2, respectively. Melt-crystallized cylindrical billets were extruded through conical dies in an Instron Capillary Rheometer. The linear polymers were found to draw by extrusion more readily than the branched; all three strain-harden. Density, birefringence, tensile, and thermal properties have been evaluated as functions of extrusion temperature and draw ratio. Despite a measured loss via die swell, substantial orientation takes place during solid-state extrusion as evidenced by increases in transparency, birefringence, and tensile modulus (up to 4.5 times that of the original isotropic polymer). Depending on the polymer and the draw temperature, density does go through a minimum or shows a monotonic increase with draw by extrusion. A minimum in modulus is also observed at low draw and at all draw temperatures for all three polymers. The highest tensile moduli achieved are 0.73, 0.46, and 1.5 GPa for A, B, and C, respectively, at their highest draw ratio. The melting point for polymer B decreases with extrusion draw ratio, whereas it remains constant after a small initial drop, for the two others. For all three low density polyethylenes, birefringence increases rapidly with extrusion draw and then levels off at high draw. The birefringence limit is similar for A and B, i.e., 0.046 ± 0.004, but higher for C, i.e., 0.068 ± 0.009. This work extends beyond others in that it studies the effect of short as well as long branches in solid-state extrusion by comparing the linear and long branched LDPE polymers and LDPE with prior evaluations of HDPE.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 29-32 
    ISSN: 0935-6304
    Keywords: Capillary supercritical fluid chromatography ; Injection techniques ; Reproducibility ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An analysis of the precision obtained using commercially available microvalve injectors is reported for three modes of injection: conventional split; timed-split; and direct. Results from this study show that good precision (〈 3% RSD for external standard and 〈 1% RSD for internal standard methods) can be obtained with capillary supercritical fluid chromatography (SFC). However, particular attention must be paid to the type of valve used, the orientation of the column relative to the valve, the mode of interfacing or connecting the column to the valve, and the type of pressure or density programming used for the analysis as all of these factors will affect the reproducibility.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...