ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Nitrogen fixation  (22)
  • NDE  (21)
  • Bone  (16)
  • Springer  (59)
  • 1980-1984  (59)
Collection
Publisher
  • Springer  (59)
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 65-74 
    ISSN: 1573-4862
    Keywords: NDE ; cast iron ; vibration analysis ; modulus ; strength
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract An outline is given of the existing nondestructive vibration tests for cast irons and their drawbacks in terms of the dimensional accuracy of the components. A proposal is made for a new test based on the change of resonant frequency with vibration amplitude exhibited by cast irons. This proposal is evaluated using material data obtained from dynamic tests of a wide range of cast iron specimens. A test rig is described suitable for testing cylindrical cast bars, and typical results are presented in relation to material strength. There is also a brief description of preliminary testing on cast products.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-4862
    Keywords: stress fields ; microstructure ; J integral ; stress intensity factor ; harness acoustic velocity ; acoustic elasticity ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract A very precise system for measuring two-dimensional velocity fields in solid samples has been used for nondestructive measurements of both externally applied and residual inhomogeneous stresses in solids,J integrals, stress intensity factors of cracks, and hardness of quenched steel. The longitudinal velocity measurement is based on precise determination of the propagation transit time through the stressed solid specimen using a small diameter, water-coupled acoutic transducer, which is scanned mechanically over the sample. Changes in velocity are then related to changes of stress in the sample by the theory of acoustoelasticity. Similar measurements show a high degree of correlation between longitudinal velocity changes and changes in microstructure in steel samples. Applications to problems of solid mechanics and material science illustrate the utility of this nondestructive measuring technique.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 2 (1981), S. 195-202 
    ISSN: 1573-4862
    Keywords: ac potential difference ; fatigue crack measurement ; slots ; artificial flaws ; parasitic voltages ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract The development of a successful and accurate instrument for measuring surface-breaking cracks in metals using the ac field technique has raised several interesting theoretical problems. Measurements with the instrument, known as the Crack Microgauge, do not rely on any prior calibration against an artificial flaw such as a saw-cut in a test block, but some users accustomed to such a calibration from other devices have nevertheless wished to use the instrument in that fashion and have in some instances reported erroneous results. In this paper, we develop a simple theory to explain and quantify this phenomenon. We calculate the parasitic voltages induced in the instrument probe due to the finite opening possessed by an artificial flaw, and we use these results to reinterpret the instrument readings. Controlled experimental measurements on artificial flaws of rectangular cross-section made in aluminum and in steel are found to be in good agreement with the theory. It is shown, however, that application of the theory requires additional information about the internal phase shift associated with the instrument. To enhance the accuracy of the theory, the effect of the corners of the artificial flaws was also considered, although it was not very influential in this work.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 3 (1982), S. 65-76 
    ISSN: 1573-4862
    Keywords: crack measurement ; ac field technique ; arbitrary skin depth ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract A general solution is given to describe the ac field around surface-breaking cracks for arbitrary values of the ratio of skin depth δ to crack depthd. This solution allows accurate interpretation of crack depth from voltage readings taken by a Crack Microgauge instrument in cases where δ andd are comparable. It is shown to agree with asymptotic formulae obtained for the cases where δ/d is very small and very large. Provided that the probe length Δ is large compared with δ, the calculations show that a very good approximation to the crack depth may be obtained, irrespective of the ratio δ/d, by using the thin-skin asymptotic formula $$d = \frac{1}{2}\Delta (V_2 - V_1 )/V_1 $$ whereV 1 andV 2 are probe voltages registered at positions just off and across the crack, respectively. The problem is solved for a crack of infinite aspect ratio which has no opening, but it can be applied with confidence at the centerline of cracks of fairly large aspect ratio.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Journal of nondestructive evaluation 4 (1984), S. 3-12 
    ISSN: 1573-4862
    Keywords: Ultrasonic ; stress measurements ; interfacial stress ; NiTi ; NDE
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology , Mathematics
    Notes: Abstract In seeking to develop an NDE technique for verifying the serviceability of NiTi couplers for plumbing unions, it was found that the reflection coefficient for a normally incident ultrasonic wave correlated with the stress level at the NiTi-tubing interface. Current theory pertaining to interface reflection is not complete but, even at present status, there is semiquantitative accord between theoretical predictions and normalized data for reflection coefficient versus stress level. These results are at fixed frequency and with comparable surface roughness. Variation of either frequency or surface roughness further affects the reflection coefficient. Current studies are being pursued to define this effect.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 33 (1981), S. 369-374 
    ISSN: 1432-0827
    Keywords: Histomorphometry ; Bone ; Reproducibility
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary To study bone histomorphometry reproducibility in normal subjects, we performed during orthopedic surgery bone biopsies in 16 post-menopausal women. Each woman had four bone biopsies, two at the usual site in the iliac crest, one on the left and one on the right side, and two other biopsies just behind the usual site, one at each side. We performed measurements of trabecular bone volume, relative osteoid volume, osteoid surfaces, osteoclastic resorption surfaces and calcification front. The average values of the 16 patients were compared, on the one hand, two by two, by a student test, and on the other hand, by a variance analysis. By these two methods the results showed no significant difference between the average values of the 16 patients at each location for any of the histomorphometric parameters studied. However, there was a location variation which was estimated by the intra-individual variation for a given patient. On the other hand, we calculated from the variance analysis the location variance for a group of 10 to 100 patients. In any case all the parameters had a location variation which was high for osteoclastic resorption surfaces and relative osteoid volume when expressed in % of the absolute value of these parameters. The variation of the trabecular bone volume was 0–46. 15% (95% confident limit interval) in a single patient and the hypothetical value of the location variation was 41.6% for a group of 10 patients and 13.0% for a group of 100 patients.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Plant and soil 66 (1982), S. 413-416 
    ISSN: 1573-5036
    Keywords: Growth ; Nematicide ; Nitrogen fixation ; Nodulation ; Peanut ; Rhizobium
    Source: Springer Online Journal Archives 1860-2000
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: Summary The effect of two granular nematicidesviz. oxamyl and fenamiphos, on the nodulation and growth of Rhizobium inoculatedArachis hypogaea L. was studied in glasshouse and field trials. In the glasshouse trial at the suggested rates of application shoot fresh weight was significantly reduced by oxamyl whilst root fresh weight was similarly affected by fenamiphos. In the field trial vegetative growth and plant emergence were significantly reduced by both nematicides. Nodulation at the higher rates of application was increased by both oxamyl and fenamiphos whilst oxamyl caused a significant increase in pod number at the highest rate of application.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Plant and soil 60 (1981), S. 139-142 
    ISSN: 1573-5036
    Keywords: Legumes ; Nitrogen fixation ; Nodulation ; Winged beans
    Source: Springer Online Journal Archives 1860-2000
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: Summary Only legumes of the cowpea cross-inoculation group, including the winged bean (Psophocarpus tetragonolobus) were found to form nodules in a temperate zone soil with no previous history of legume cropping. Isolates from root nodules from uninoculated winged beans grown in the field only nodulated legumes in the cowpea cross-inoculation group.Rhizobium japonicum formed ineffective nodules with the winged bean.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Calcified tissue international 36 (1984), S. S7 
    ISSN: 1432-0827
    Keywords: Bone ; Mechanical function
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary The variety of different mechanical functions required of whole bones is discussed. Often, the design optimizing the structure for one function is not optimal for another function.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1432-0827
    Keywords: Bone ; Osteosarcoma ; Matrix vesicles ; Alkaline phosphatase ; Aminopeptidase ; Naphthylamidase
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine , Physics
    Notes: Summary Extracellular matrix vesicles from bovine fetal alveolar bone and from a dog osteosarcoma were isolated by differential centrifugation and then fractionated on a discontinuous sucrose density gradient. The fractions were examined by electron microscopy and were analyzed for protein, alkaline phosphatase, aminotripeptidase, and four different β-naphthylamidase activities. The low-density peak of enzyme activities was shown by electron microscopy to be much more homogeneous than the crude matrix vesicle fraction. Two major peaks of protein and enzyme activities were present, one in the high and one in the low density layers. There was good correlation between the activities of alkaline phosphatase and the various peptidases in the fractions from the sucrose density gradient. These results indicate a coexistence of peptidase and alkaline phosphatase in matrix vesicles. On the other hand, there was generally no correlation between the peptidase and alkaline phosphatase activities in vesicular specimens from bovine liver obtained in the same way. Most of the peptidase activity and about half of the alkaline phosphatase activity were solubilized from bone matrix vesicles by detergents. The extracted alkaline phosphatase and alanyl β-naphthylamidase activities were separated from each other on a DEAE-cellulose column.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...