ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Pure and applied geophysics 147 (1996), S. 389-407 
    ISSN: 1420-9136
    Keywords: Monitoring of microearthquakes ; salt diapir ; seismotectonics of Provadia (Bulgaria)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract By analysis of microtremors recorded with digital seismological monitoring equipment near the Provadia salt diapir (Bulgaria), two groups of events showing different characteristics have been detected in the vicinity of the salt production area. The first group of events has low magnitudes and is located at a distance of about 1 km from the top of the salt diapir. These events show low stress drops. The second group of tremors is located outside the salt diapir. The corresponding magnitudes and stress drops are larger. The first class of events seems to be related to processes at the contour of the salt leaching caverns, whereas the origin of the second group seems to be connected with stress redistribution processes around the salt body. Based on this analysis, the tectonic model of the Provadia salt diapir has been modified.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1618-2650
    Keywords: Best. von Elementspuren in Organ. Material ; Verbrennungsapparatur ; Sauerstoffstrom
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A partially mechanized apparatus made of quartz (Trace-0-Mat) is described that permits the complete mineralization of up to 1 g of organic or biological solid samples. The combustion takes place in pure oxygen in a very small burning chamber (ca. 75 cm3) to subsequently determine metallic and nonmetallic trace elements (1 ng/g) with high reliability. The controllable incineration is started with an IR-radiator system. All volatile trace elements (e.g. Hg, Se, Te, As, Sb, I) are condensed together with the products of the combustion process in a cooling system filled with liquid nitrogen that is mounted on top of the burning chamber. Subsequent refluxing with a suitable acid in a quartz test tube mounted below the burning chamber collects both the volatilized elements from the cooled areas and nonvolatile elements in the ashing residue. The volume of the acid is about 2 ml. The recoveries of the elements following the decomposition process that takes 50–60 min for one sample was checked using 7 NBS-Standard Reference Materials for the elements B, Cr, Cu, Fe, Mn, Zn (ICP-emission spectrometry), Cd, Pb (ETA-AAS), Hg (AAS-cold vapor technique), As (AAS-hydride method) and Se (XRF). Very good agreement with the certified values was observed. This furnished evidence that this new and very general decomposition method is not only poor in blanks but also avoids substantially losses of the elements to be determined by volatilization, adsorption or even baking in the quartz surface. The easy handling of the apparatus offers the best premises for a reliable determination of trace elements in the μg/g and ng/g range in most non-volatile organic matrices.
    Notes: Zusammenfassung Ein teilmechanisiertes aus Quarz bestehendes System (Trace-0-Mat) wird beschrieben, das die vollständige Mineralisation fester organischer oder biologischer Proben bis zu Mengen von 1 g gestattet. Die Verbrennung findet dabei in reinem Sauerstoff in einer sehr kleinen Verbrennungskammer (etwa 75 cm3) statt, so daß anschließend die metallischen und nichtmetallischen Spurenelemente mit hoher Zuverlässigkeit bestimmt werden können. Die steuerbare Veraschung wird durch ein System von IR-Strahlern gestartet. Alle flüchtigen Spurenelemente (z. B. Hg, Se, Te, As, Sb, I) werden zusammen mit den Verbrennungsprodukten in einem Kühlsystem kondensiert, das mit flüssigem Stickstoff gefüllt und über der Verbrennungskammer angeordnet ist. Die sich an den gekühlten Flächen befindlichen flüchtigen sowie die in der Asche vorhandenen nichtflüchtigen Elemente werden durch Rückflußbehandlung mit einer kleinen Säuremenge (2 ml) gelöst und in einem Quarzglas unterhalb der Verbrennungskammer gesammelt. Die Wiederfindung der Elemente nach dem Aufschlußprozeß (50–60 min) wurde mit Hilfe von 7 NBS-Referenzmaterialien für folgende Elemente geprüft: B, Cr, Cu, Fe, Mn, Zn (ICP-Emissionsspektrometrie), Cd, Pb (ETA-AAS), Hg (AAS-Kaltdampftechnik), As (AAS-Hydridmethode) und Se (Röntgenfluorescenz). Es ergab sich sehr gute Übereinstimmung mit den zertifizierten Werten. Diese neue und sehr allgemein anwendbare Aufschlußmethode weist nicht nur geringe Blindwerte auf, sondern vermeidet auch wesentliche Verluste der zu bestimmenden Elemente durch Verflüchtigung, Adsorption oder Zusammenbacken an der Quarzoberfläche. Durch die einfache Handhabung der Apparatur ist eine zuverlässige Bestimmung von Spurenelementen im μg/g- und ng/g-Bereich für die meisten nichtflüchtigen organischen Matrices gewährleistet.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...