    Publication Date: 2013-08-29
    Description: NASA Goddard Space Flight Center's Airborne Raman Ozone, Temperature and Aerosol Lidar (AROTEL) measured extremely cold temperatures during all three deployments (December 1-16, 1999, January 14-29, 2000 and February 27-March 15, 2000) of the Sage III Ozone Loss and Validation Experiment (SOLVE). Temperatures were significantly below values observed in previous years with large regions regularly below 191 K and frequent temperature retrievals yielding values at or below 187 K. Temperatures well below the saturation point of type I polar stratospheric clouds (PSCs) were regularly encountered but their presence was not well correlated with PSCs observed by the NASA Langley Research Center's Aerosol Lidar co-located with AROTEL. Temperature measurements by meteorological sondes launched within areas traversed by the DC-8 showed minimum temperatures consistent in time and vertical extent with those derived from AROTEL data. Calculations to establish whether PSCs could exist at measured AROTEL temperatures and observed mixing ratios of nitric acid and water vapor showed large regions favorable to PSC formation. On several occasions measured AROTEL temperatures up to 10 K below the NAT saturation temperature were insufficient to produce PSCs even though measured values of nitric acid and water were sufficient for their formation.
    Keywords: Ground Support Systems and Facilities (Space)
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-07-18
    Description: The Ozone Monitoring Instrument (OMI) is the Dutch-Finnish contribution to NASA's EOS-Aura satellite scheduled for launch in January 2004. OMI is an imaging spectrometer that will measure the back-scattered Solar radiance in the wavelength range of 270 to 500 nm. The instrument provides near global coverage in one day with a spatial resolution of 13x24 square kilometers. OMI is a new instrument, with a heritage from TOMS, SBW, GOME, GOMOS and SCIAMACHY. OMI'S unique capabilities for measuring important trace gases and aerosols with a small footprint and daily global coverage, in conjunction with the other Aura instruments, will make a major contribution to our understanding of stratospheric and tropospheric chemistry and climate change. OMI will provide data continuity with the 23-year ozone record of TOMS. There are three ozone products planned for OMI: total column ozone, ozone profile and tropospheric column ozone. We are developing two different algorithms for total column ozone: one similar to the algorithm currently being used to process the TOMS data, and the other an improved version of the differential optical absorption spectroscopy (DOAS) method, which has been applied to GOME and SCIAMACHY data. The main reasons for starting with two algorithms for total ozone have to do with heritage and past experience; our long-term goal is to combine the two to develop a more accurate and reliable total ozone product for OMI. We will compare the performance of these two algorithms by applying both of them to the GOME data. We will examine where and how the results differ, and use the extensive TOMS-Dobson comparison studies to assess the performance of the DOAS algorithm.
    Keywords: Instrumentation and Photography
    Type: EGS-AGU-EUG Joint Assembly 2003; Apr 07, 2003 - Apr 11, 2003; Nice; France
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-07-18
    Description: OMI is an advanced hyperspectral instrument that measures backscattered radiation in the UV and visible. It will be flown as part of the EOS Aura mission and provide data on atmospheric chemistry that is highly synergistic with other Aura instruments HIRDLS, MLS, and TES. OMI is designed to measure total ozone, aerosols, cloud information, and UV irradiances, continuing the TOMS series of global mapped products but with higher spatial resolution. In addition its hyperspectral capability enables measurements of trace gases such as SO2, NO2, HCHO, BrO, and OClO. A plan for validation of the various OM1 products is now being formulated. Validation of the total column and UVB products will rely heavily on existing networks of instruments, like NDSC. NASA and its European partners are planning aircraft missions for the validation of Aura instruments. New instruments and techniques (DOAS systems for example) will need to be developed, both ground and aircraft based. Lidar systems are needed for validation of the vertical distributions of ozone, aerosols, NO2 and possibly SO2. The validation emphasis will be on the retrieval of these products under polluted conditions. This is challenging because they often depend on the tropospheric profiles of the product in question, and because of large spatial variations in the troposphere. Most existing ground stations are located in, and equipped for, pristine environments. This is also true for almost all NDSC stations. OMI validation will need ground based sites in polluted environments and specially developed instruments, complementing the existing instrumentation.
    Keywords: Instrumentation and Photography
    Type: EGS-AGU-EUG Joint Assembly 2003; Apr 07, 2003 - Apr 11, 2003; Nice; France
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-07-18
    Description: The Total Ozone Mapping Spectrometer (TOMS) series comprises four instruments providing a total of 25 years of daily global stratospheric ozone data over the sunlit portion of the Earth. A new retrieval algorithm has been developed for TOMS, designated Version 8. The algorithm is based on differential absorption across a pair of wavelength channels chosen close together to minimize the impact of wavelength dependent forward modeling errors. Version 8 enhancements include correction for the presence of tropospheric aerosols and sun glint from water surfaces, a better treatment of variability due to tropospheric ozone and temperature dependence, and an improved forward model, particularly in regions of persistent snow and ice. Among other things, the Version 8 enhancements have reduced latitudinal dependence seen previously in TOMS - Dobson comparisons, predominantly in the Southern Hemisphere's summer, when the tropospheric ozone, temperature, and snow/ice corrections are additive. The basic components of the algorithm and its impact on derived total ozone will be discussed.
    Keywords: Instrumentation and Photography
    Type: EGS-AGU-EUG Joint Assembly 2003; Apr 07, 2003 - Apr 11, 2003; Nice; France