ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    facet.materialart.
    Unknown
    In:  Bull. Seism. Soc. Am., Minsk, Polish Geothermal Association, vol. 70, no. 3, pp. 379-383, pp. TC5003, (ISSN: 1340-4202)
    Publication Date: 1980
    Keywords: Seismology ; Magnitude ; seismic Moment ; BSSA
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2017-04-04
    Description: For an optimal analysis of the H/V curve, it appears necessary to check the instrument signal to noise ratio in the studied frequency band, to ensure that the signal from the ground noise is well above the internal noise. We assess the reliability and accuracy of various digitizers, sensors and/or digitizer-sensor couples. Although this study is of general interest for any kind of seismological study, we emphasize the influence of equipment on H/V analysis results. To display the impact of the instrumental part on the H/V behavior, some series of tests have been carried out following a step-by-step procedure: first, the digitizers have been tested in the lab (sensitivity, internal noise...), then the three components sensors, still in the lab, and finally the usual user digitizers-sensors couple in lab and outdoors. In general, the digitizer characteristics, verified during this test, correspond well to the manufacturer specifications, however, depending on the digitizer, the quality of the digitized waveform can be very good to very poor, with variation from a channel to another channel (gain, time difference etc.). It appears very clearly that digitizers need a warming up time before the recording to avoid problems in the low-frequency range. Regarding the sensors, we recommend strongly to avoid the use of “classical” accelerometers (i.e., usual force balance technology). The majority of tested seismometers (broadband and short period, even 4.5 Hz) can be used without problems from 0.4 to 25 Hz. In all cases, the instrumentation should be checked first to verify that it works well for the defined study aim, but also to define its limit of use (frequency, sensitivity...).
    Description: Published
    Description: 3-31
    Description: 4.1. Metodologie sismologiche per l'ingegneria sismica
    Description: JCR Journal
    Description: reserved
    Keywords: H/V technique ; Instrumentation ; Microtremors ; Site effects ; 04. Solid Earth::04.06. Seismology::04.06.99. General or miscellaneous ; 04. Solid Earth::04.06. Seismology::04.06.10. Instruments and techniques
    Repository Name: Istituto Nazionale di Geofisica e Vulcanologia (INGV)
    Type: article
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...