ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • INSTRUMENTATION AND PHOTOGRAPHY  (6)
  • Calmodulin  (3)
  • 1
    ISSN: 1432-2048
    Keywords: Actin ; Calmodulin ; Ernodesmis ; Microfilament ; Microtubule ; Tubulin ; Wound healing (alga)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract The involvement of calmodulin (CaM) in wound-induced cytoplasmic contractions in E. verticillata was investigated. Indirect immunofluorescence of CaM in intact cells showed a faint, reticulate pattern of fluorescence in the cortical cytoplasm. Diffuse fluorescence was evident deeper within the cytoplasm. In contracted cells, CaM co-localizes with actin in the cortical cytoplasm in extensive, longitudinal bundles of microfilaments (MFs), and in an actin-containing reticulum. No association of CaM with tubulin was ever observed in the cortical cytoplasm at any stage of wound-healing. When contraction rates in wounded cells are measured, a lag period of 2 min is followed by a rapid, steady rate of movement over the subsequent 10 min. The delay in the initiation of longitudinal contraction corresponds to the time necessary for the assembly of the longitudinal MF bundles. Cytoplasmic motility was inhibited in a dose-dependent manner by CaM antagonists. In these inhibited cells, MF bundles did not assemble, or were poorly formed. In the latter case, CaM was always found associated with MFs. These results indicate a direct spatial and temporal correlation between CaM and actin, and a potential role for CaM in regulating the formation of functional MF bundles during wound-induced cytoplasmic contraction in Ernodesmis.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-2048
    Keywords: Actin ; Calmodulin ; Ernodesmis ; Membrane skeleton ; Microfilaments
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Abstract Ultrastructural changes in the cortical cytoskeleton during wound-induced cytoplasmic contraction were examined in the coenocytic green alga Ernodesmis verticillata. Both calmodulin (CaM) and actin were localized in intact and contracting cells by immunogold labeling. Within 5 min after wounding, compact microfilament (MF) bundles were observed which increase in diameter as cytoplasmic contraction proceeds. Calmodulin labeling is associated with amorphous material studding the MF bundles, whereas actin labeling occurs along the individual MFs. No MF bundles were ever observed during contraction that were not also labeled with anti-CaM antibodies. In cells treated with the CaM antagonist W-7 (N-[6-aminohexyl]-5-chloro-1-naphtha-lenesulfonamide), MF bundles do not form, and the formation of loosely arranged MFs (similar to nascent bundles in untreated cells) is greatly retarded. We propose that CaM binds indirectly to actin by activating an actin-binding regulatory protein which functions in early stages of the transduction sequence leading to functional MF bundles. Additionally, ultrastructural evidence is presented for a plasma-membrane skeleton or undercoating in this alga.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1615-6102
    Keywords: Alga ; Actin ; Calmodulin ; Ernodesmis ; Membrane recycling ; Microfilaments
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Summary Changes in the plasma membrane surface and in the cortical cytoplasm during wound healing in giant green algal cells ofErnodesmis verticillata (Kützing) Bφrgesen were followed using scanning and transmission electron microscopy. Microvillus-like structures that contain cytoplasmic and cytoskeletal constituents were observed emanating from the surface of the plasma membrane at the retracting/cut end of wounded cells. These delicate structures seem to be remnants of cell wall-plasmalemma connections that draw out the plasma membrane and cortical components from the contracting cytoplasm as it pulls away from the cell wall. Most of these connections break during wound healing and, when contraction stops, the microvillus-like protrusions become progressively shorter. In cells treated with a calmodulin antagonist (W-7), a number of distinctive bodies accumulate that are of unknown composition, are oblong in shape, and have a diameter slightly smaller than the protoplasmic protrusions. Ultrastructural and other data indicate that these bodies result from retrieved constituents of the plasma-membrane protrusions, as they do not accumulate in unwounded drugtreated cells or in cells treated in W-5. These findings suggest that the protoplasmic protrusions accumulate membrane and cytoplasmic components that are retrieved and recycled during wound healing inErnodesmis by a novel mechanism. The combined plasma membrane surfaces of the microvillus-like protrusions may help to account for the drastic decrease in surface area that occurs during wound healing.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2019-06-28
    Description: Recent progress in the development of a gravity-sensor-based instrument for determining the elevation angle of DSN antennas is described. The benefits of such a system include the capability to locate the Gravity Referenced Elevation Encoder (GREE) directly on the primary reflector (thus bypassing structural flexure and deformation error sources), anticipated lower maintenance costs compared to the present gimbal encoders, direct replaceability, or supplementation of the present gimbal encoders and the utilization of off-the-shelf components to construct the GREE. This article includes a description of the nominal GREE design. Test results on a laboratory breadboard model are given. Rigid-body dynamics of the GREE are derived and the simulated performance in response to measured antenna vibrations is given.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: The Telecommunications and Data Acquisition Report; p 63-73
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2019-06-27
    Description: On Dec. 12, 1970, the UHURU X-ray observatory was launched into equatorial orbit with the prime mission of conducting an all-sky survey of astronomical X-ray sources with intensities of 0.00005 Sco-X1 or greater. The X-ray detection system contains 12 gas-filled proportional counters, 6 behind each collimator. The aspect system is discussed together with the structure, the pulse height analyzer, the command system, the calibration system, and the power distribution system. Pulse shape discrimination circuits used on UHURU use the same technique that was used on the system originally developed for large area proportional counters described by Gorenstein and Mickiewicz (1968).
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2019-06-27
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Review of Scientific Instruments; 50; June 197
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-08-13
    Description: Laboratory test results of the initialization and tracking performance of an existing inertial-sensor-based instrument are given. The instrument, although not primarily designed for precision antenna pointing applications, demonstrated an on-average 10-hour tracking error of several millidegrees. The system-level instrument performance is shown by analysis to be sensor limited. Simulated instrument improvements show a tracking error of less than 1 mdeg, which would provide acceptable performance, i.e., low pointing loss, for the Deep Space Network 70-m antenna subnetwork, operating at Ka-band (1-cm wavelength).
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: The Telecommunications and Data Acquisition Report 42-109: January-March 1992; 94-104
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2019-07-13
    Description: On Dec. 12, 1970, the United States Small Astronomy Satellite-A was launched into orbit around the earth. The X-ray instrument carried by the spacecraft was the first satellite instrument to be devoted exclusively to the study of stellar X-ray sources. The primary objective of the instrument was to perform an all-sky survey to detect and locate stellar X-ray sources with location accuracies of one arc-minute for the stronger sources. A system description is given together with details of circuits, alignment procedures, and calibration sequences.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Annual Technical Meeting; Oct 16, 1972 - Oct 18, 1972; San Mateo, CA
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-07-13
    Description: Description of the star sensor used in the spin-stabilized Uhuru satellite for the purpose of detecting and locating stellar X-ray sources. The star sensor had the capability of detecting fourth-magnitude stars to within 1 arc minute of azimuth and 2 arc minutes of elevation. This was achieved with the aid of a slightly modified 76-mm, f/0.87 Super Farron lens, an 'n' shaped reticle located in the focal plane, and an RCA CF70114F photomultiplier serving as the detection element. The star sensor is composed of three major components - a high-voltage power supply, the photomultiplier, and an amplifier.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Annual Electro-Optical Systems Design Conference; Sep 12, 1972 - Sep 14, 1972; New York, NY
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...