ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • FLUID MECHANICS AND HEAT TRANSFER  (1)
  • Fused silica capillary columns  (1)
  • 1985-1989  (2)
  • 1960-1964
  • 1955-1959
  • 1945-1949
Collection
Publisher
Years
  • 1985-1989  (2)
  • 1960-1964
  • 1955-1959
  • 1945-1949
Year
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 548-554 
    ISSN: 0935-6304
    Keywords: Gas liquid chromatography (GLC) ; Fused silica capillary columns ; Alkali flame ionization detection (AFID) ; Mass spectrometry (MS) ; Quantitation in human serum ; Ethylenediamine ; Aminophylline ; Small molecular weight amines and diamines ; m-Toluoyl derivatives ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A specific and sensitive method for the determination of ethylenediamine in human plasma is described. The aqueous sample is treated with m-toluoyl chloride, yielding the N,N′-bis(m-toluoyl) derivative of the diamine, which is extracted into dichloromethane and quantitated after “on column” methylation by capillary gas liquid chromatography with alkali flame ionization detection. The corresponding derivative of putrescine serves as internal standard. The assay is reproducible and calibration curves are linear over the concentration range 0.05 to 10 μg · ml-1. The lower detection limit is about 10 ng · ml-1. The structures of the compounds of interest eluting from the capillary column are examined by gas liquid chromatography/mass spectrometry. The assay has been applied to the analysis of ethylenediamine in plasma following the administration of aminophylline and ethylenediamine in a cross-over study to patients with bronchopulmonary diseases. The method also proves suitable for measuring other primary and secondary amines and diamines in aqueous solutions by gas liquid chromatography.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-06-28
    Description: Developing flows in two out-of-plane double S-bend configurations have been measured by laser-Doppler anemometry. The first duct had a rectangular cross-section 40mmx40mm at the inlet and consisted of a uniform area 22.5 deg. - 22.5 deg. S-duct upstream with a 22.5 deg.- 22.5 deg. S- diffuser downstream. The second duct had a circular cross-section and consisted of a 45 deg. - 45 deg. uniform area S-duct upstream with a 22.5 deg. -22.5 deg. S-diffuser downstream. In both configurations the ratio of the mean radius of curvature to the inlet hydraulic diameter was 7.0, the exit-to-inlet area ratio of the diffusers was 1.5 and the ducts were connected so that the centerline of the S-duct lay in a plane normal to that of the S-diffuser. Streamwise and cross-stream velocity components were measured in laminar flow for the rectangular duct and in turbulent flow for both configurations; measurements of the turbulence levels, cross-correlations and wall static pressures were also made in the turbulent flow cases. Secondary flows of the first kind are present in the first S-duct and they are complemented or counteracted by the secondary flows generated by the area expansion and by the curvature of the S-diffusers downstream. Cross-stream velocities with magnitudes up to 0.19 and 0.11 of the bulk velocity were measured in the laminar and turbulent flows respectively in the rectangular duct and six cross-flow vortices were evident at the exit of the duct in both flow cases. The turbulent flow in the circular duct was qualitatively similar to that in the rectangular configuration, but the cross-stream velocities measured at the exit plane were smaller in the circular geometry. The results are presented in sufficient detail and accuracy for the assessment of numerical calculation methods and are listed in tabular form for this purpose.
    Keywords: FLUID MECHANICS AND HEAT TRANSFER
    Type: NASA-CR-176981 , NAS 1.26:176981 , FS/86/30
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...