ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 6 (1992), S. 697-701 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Results are oresented for various instrumental configurations employed for matrix-assisted laser desorption mass spectrometry. Mass resolution is determined for a linear time-of-flight mass spectrometer for various lengths of the field-free region. A wire ion guide is utilized and is shown to improve ion transport efficiencies for longer field-free regions. It is also determined experimentally that a modest mass resolution increase is often obtained in configurations employing the wire ion guide when compared to the mass resolution obtained with the same geometr without the wire ion guide. Optimal applied potentials are determined for the wire ion guide. No mass dependence on the opitmal applied potential (-100 V) for the wire ion guide is observed for samples of equine myoglobin (MW 16 951.5 Da) and a bacterial protease (MW 27 228.4 Da). The optimal applied voltage was also found to b identical (-100 V) for the singly through quadruply charged molecular ion species of rabbit gamma globulin (MW ≍ 150 000 Da). It is shown that a 2 m flight tube with a wire ion guide provides better signal-to-noise mass spectra than a 1 m flight tube without the wire ion guide and can more than double the mass resolution obtainable. Utilization obtainable. Utilization of a 4 m flight tube gives minimal mass resolution enhancement at the expense of signal-to-noise.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 16 (1988), S. 377-380 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A new inorganic mass spectrometric technique is described which allows sensitive, rapid and economic determination of trace element concentrations and isotope ratios in aqueous samples. This paper illustrates the potential of the technique in one particular application area, namely the measurement of strontium isotope ratios in human blood and urine following ingestion of an enriched stable strontium isotope. The data from a human volunteer experiment illustrate the viability of the analytical method, with measurement precisions of ± 0.2% (1σ) achieved for the isotope ratio in urine samples, which contained approximately 300 ng 86Sr in the volume required for analysis. Measurement precision is limited by counting statistics.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 6 (1992), S. 690-696 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The ion detection process in a discrete-dynode electron multiplier can result in significant mass resolution losses in time-of-flight mass spectrometry (TOF-MS) for higher mass-to-charge (m/z) ion species. This resolution loss is attributed to propagation time delays and signal broadening in the ion detector. This is presumed tobe due to the generation o a distribution of secondary ion species produced initially upon impact of a primary ion with the first ynoe surface of the ion detector. Comparisons are made between the signals produced by a standard discrete dynode ion detector (which amplified the negatively chqrged species produced by impact of a primry ion) and a detector modified to respond to only the positively charged secondary ion species produced by a primary ion impact. Ion signals for higher m/z ions with the standard detector geometry are see to be due to a narrow signal component, most likely due to the generation o secondary electrons and/or very low mass secondary ions (H-), and a broad signal component, apparently due to secondary ions which take signifiant amounts of time to traverse the low potential fields between the first and second detector dynode. This results in ion signal tailing for higher m/z ion species. Numerical subtraction of the ion signal obtained with the standard and modified detector geometries (singly protonated molecular ion species of equine myoglobin) results in an improvement in mass resolution, such that a new adduct ion species (from trifluoroacetic acid) can be resolved.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Resonance effects on measured isotope ratios in lead using three-photon one-colour resonance ionization mass spectrometry are discussed. The shape of the ionization signal is considered for the case of a non-monochromatic laser field. The intensity of the laser radiation is adjusted to be low enough not to cause saturation of the transitions. The variation of the measured isotope ratio as a function of laser frequency is considered. It is shown that the deviation of the measured from the expected isotope ratio, for a Lorentzian laser lineshape equals the ratio of the isotope shift to the laser bandwidth. Unfortunately, the background noise in the experiments makes verification of this behaviour difficult for the isotopes of low abundance.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 43 (1991), S. 1287-1292 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The standard 90° peel test was modified in order to apply it to testing adhesion of thin polymer films to surfaces of silicon substrates, such as the silicon nitride passivation layer used in our solid-state chemical sensors. The goal of this task was to develop a procedure for testing adhesion of both dry and wet films, which would yield repeatable, quantitative results quickly, and with simple sample preparation. It is important to produce valid comparisons of adhesion both over variations of a given polymer composition, and between films made of dissimilar polymer matrices. The method described herein could be applied to adhesion testing of a wide variety of thin polymer layers to solid surfaces.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 57 (1995), S. 133-137 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The effect of temperature, postcure, and fiber orientation on water absorption were examined for Kerimid® 723 bismaleimide resin. The effect of fiber orientation was also examined for Avimid® N and BASF X-5260. Water absorption in Kerimid® 723 was found to have an Arrhenius temperature dependence, depend on degree of postcure, and be independent of fiber orientation. BASF X-5260 water absorption was also found to be independent of fiber orientation. Avimid® N water absorption exhibited a strong dependence on fiber orientation. © 1995 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 18 (1974), S. 1079-1082 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The crosslink density of small microtomed samples of rubber vulcanizates has been determined using a gas-chromatographic method for estimating the amount of solvent in the swollen rubber. The method may be used for determining the variation in crosslink density through thick rubber articles, for determining the change in crosslink density after aging service, or, for the investigation of rubber bonds and interfaces.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 16 (1974), S. 659-673 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The time course of release of intact labile material from cells by cavitating ultrasound is examined. Curves are presented which show the yield of intact subcellular components obtainable from cells as a function of sonication time for various values of the ratio of inactivation rate to release rate. The general cases where inactivation of released product is concentration dependent (chemical) and concentration independent (mechanical) are considered.For a flow system the time of attainment of equilibrium concentration of active product is analyzed as a function of flow rate, release rate, inactivation rate, and volume of chamber. Curves of optimal yields to be expected for batch and flow systems are presented. It is shown that sonochemical inactivation can be made negligible by sonication of high cell concentration suspensions.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 34 (1988), S. 2063-2068 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 14 (1968), S. 657-658 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...