ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (130)
  • Chemical Engineering  (117)
  • 1980-1984  (169)
  • 1970-1974  (78)
  • 1980  (169)
  • 1972  (78)
Collection
Publisher
Years
  • 1980-1984  (169)
  • 1970-1974  (78)
Year
  • 1
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: As part of a study to make a comparative analysis of selected halogenated compounds in man and the environmental media, a quantitative gas chromatographic mass spectrometric analysis of the levels of the halogenated compounds found in the breath, blood and urine of an exposed population (Old Love Canal area, Niagara, New York) and their immediate environment (air and water) was undertaken. In addition, levels of halogenated hydrocarbons in air samples taken in the general Buffalo, Niagara Falls area were determined.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Journal of Raman Spectroscopy 9 (1980), S. 230-238 
    ISSN: 0377-0486
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The IR spectra (1400 cm-1 to 160 cm-1) of the gases at ambient temperature and the Raman spectra (below 1400 cm-1) of the liquids near -196°C are reported for CF3OF and CF3OCl. All fundamentals are assigned under Cs symmetry and the results of a normal coordinate analysis are presented. The assignments of Smardzewski and Fox are adopted with one exception for both CF3OF and CF3OCl: the CF3 rock of A″ symmetry is assigned near 430 cm-1 and the two bands between 200 cm-1 and 300 cm-1 are assigned to an A′ fundamental, involving CF3 rocking and COX bending and a Δν=2 transition in the CF3 torsion. An extra band at 548 cm-1 in the Raman spectrum of liquid CF3 COl near -196°C is assigned to a CF3OCl⃛Cl2 complex. The values of the force constants d(OX) for CF3OX molecules are suggested to be near those for X2O molecules. More than half the normal modes of A′ symmetry show extensive mixing of symmetry coordinates. In some of these cases the symmetry coordinate for which the normal mode is named is the largest but not the dominant contributor to the potential energy distribution, while in others this symmetry coordinate is not even the largest contributor to the potential energy distribution. No normal modes of A′ symmetry are present in which ν(CO), δs(CF3), δ(COX), or δ(CF3) symmetry coordinates are dominant, and the mode conventionally labeled as v(CO) should be labeled as νs(CF3). For the remaining A′ normal modes and all the A″ normal modes, the symmetry coordinate for which the normal mode is named is dominant in the potential energy distribution.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 528-530 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Two-phase derivatization technique ; Yeast ; Splitless injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 7 (1980), S. 242-246 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The electron impact, methane positive chemical ionization, oxygen negative chemical ionization and collision induced dissociation mass analyzed ion kinetic energy spectra of nine metabolites of di-(2-ethylhexyl)phthalate are presented. The collision induced dissociation mass analyzed ion kinetic energy spectra of selected fragment ions were useful for structural information.
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The value of selected ion monitoring in analyzing biological radio isotope incorporation experiments by radiogas chromatography mass spectrometry is illustrated with reference to the biosynthesis of the mycotoxin mycophenolic acid and the mode of action of the anticholesterolemic drug 20,25-diazacholesterol. It is shown that the increased sensitivity and specificity of the selected ion monitoring mode detector permits straightforward detection and identification of the relatively small cellular pools associated with metabolic intermediates. The computer program RADSIM is described. Problems that still exist in using radiogas gas chromatography mass spectrometry technology to analyse isotope incorporation experiments are discussed.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Gas chromatography using a short packed column (45 cm, 0.2 cm i.d., 2% OV-101 on Gas-Chrom Q) with mass spectrometric detection in the selected ion monitoring mode has been found satisfactory for the analysis of lower as well as higher polybrominated biphenyls. Acceptable sensitivity (〈1 ng) may be achieved for this method by focusing selectively at either the low (m/z 20-600) or the high (m/z 600-1000) range of the quadrupole filter (low range for mono- through hexabromobiphenyl, high range for hexa- through decabromobiphenyl). A tuning technique has been developed for low range and high range polybrominated biphenyls using the ion abundances of perfluorotributylamine as a standard. Standard ions for the quantitation of mono- through decabromobiphenyls were selected and validated. The technique was applied to the analysis of a variety of environmental samples.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 7 (1980), S. 381-384 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An improved analog four-channel selected ion recording system is described, in which major modifications permit a decrease in the dwell time to 33 ms per channel, thus minimizing the mass cycling error. Synchronization with a sinusoidal sweep voltage superimposed on the normal accelerating voltage (8 kV) enables two channels to be monitored simultaneously in real time and each mass to be recorded continuously. These improvements allow measurement of ion current ratios with a precision of 0.2% over a wide dynamic range, permitting accurate determination of isotopic enrichment in biomedical assays even when this enrichment is derived from a single label. Use of the system is illustrated by the analysis of palmitate turnover in dogs (using [1 - 13C] palmitic acid) with an average standard deviation corresponding to the detection of 0.04% excess of [1 - 13C] palmitate.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: In this paper we describe the operation of a rheometer that is capable of measuring the viscoelastic response of a polymer melt in a biaxial or planar extensional flow field under circumstances wherein the deformation history can be varied in an arbitrary manner. The principal feature of this rheometer is the use of a closed loop feedback system to control the inflation of a flat, molten polymer sheet clamped around its periphery. The feedback system is especially designed so that either stress or strain can be used as the reference point, thus permitting the deformation history to be varied arbitrarily. Illustrative data are presented on the viscoelastic response of a molten acrylonitrile-butadiene-styrene copolymer subjected to a planar extensional flow for the following deformation histories: constant stress, constant strain, constant strain rate, oscillatory stress and oscillatory strain.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 12 (1972), S. 167-178 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: An experimental program was conducted to study the thermochemical and flammability characteristics of an improved polyisocyanurate foam, uncoated and coated either with fluorinated copolymer or an intumescent material. Testing methods included thermal analysis; scanning electron microscopy; infrared photography; infrared spectroscopy; HLT-15, ASTM D-1692, Bureau of Mines Penetration, and XP-2 smoke chamber flammability tests; limiting oxygen index (LOI); and a moderate-scale fire simulation test. The uncoated and coated foams were found to have excellent flammability and insulation characteristics, although smoke development was substantial.
    Additional Material: 22 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 18 (1972), S. 798-807 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Secondary nucleation in the potassium sulfate-water system occurs by micro-attrition processes over the entire 1.3-26 μ size range of this study. Experimental nucleation rates were correlated with power-law kinetics expressions in terms of supersaturation, the fourth moment of the parent seed-crystal distribution, and stirring rate. Such kinetics expressions are similar to those used to correlate MSMPR data; however, the secondary nucleation rates of this paper are two orders of magnitude greater than those reported in previous MSMPR studies of the same system. An upper bound on growth rate of these nuclei was calculated based on a population balance analysis; maximum growth rates of these nuclei was markedly size-dependent in the 1.3-26 micron size range of measurement, decreasing with decreasing size. The apparent descrepancy between these nucleation rates and MSMPR values can be explained by nuclei washout during the low growth rate period. Anomalous MSMPR kinetics (low or even negative supersaturation power-law dependence) can be explained by this growth phenomenon.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...