ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 31-35 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Surface deactivation, silylation ; Inertia stable to 350° ; Free acids and bases, simultaneous injection ; On-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A deactivation procedure is described based on a published method using hexamethyldisilazane in the gas phase. In addition to unusually high inertia and thermostability, the method produces truly neutral columns which allow simultaneous analysis of moderately strong free acids and bases. The silylated columns show their full potential only with on-column injection. Preliminary experimental directions are given; more elaborate directions will become available after extended optimization work.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 57-64 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Splitless injection, basis of ; Use for any sample ; Optimization ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Splitless injection is based on the solvent effect as a mechanism condensing large vapour clouds down to infinitely shortened bands. The effect is controlled by the parameters column temperature, volatility and amount of solvent, and rate of injection. By properly selecting the variables the effect can easily be optimized for any combination of sample and column. It is the purpose of this paper to provide the mechanistic understanding as required for this optimization, as well as some rules for the experimental realization. Potentialities and limitations of splitless injection are discussed, and the role of the solvent effect in on-column injection is emphasized.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 149-155 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Capillary, glass ; Preparation of apolar columns ; Ba CO3 procedure optimized for thermostability acid/base behaviour and efficiency ; New, quantitative testing procedure ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: As an extension of previous reports, the barium carbonate procedure has been optimized in detail for the preparation of apolar columns. The aim was to produce optimum overall column characteristics, and to maintain them unchanged under the prolonged influence of the highest possible temperature. The main parameters under optimization were glass variety, leaching of glass surface with aqueous HCl, and amount of barium carbonate deposited, while deactivation and coating were kept constant. The basic column characteristics were adsorption properties and thermostability of deactivation, acid/base behaviour and separation efficiency. They were determined by a new, quantitative testing procedure. Intense leaching was able to eliminate almost totally the differences between glass varieties and to create a well-defined glass surface. While untreated glass, leached glass, and barium carbonate treated glass showed specific weak points in the respective column quality, the combination of leaching and barium carbonate treatment yielded the highest and most stable quality. Some technical modifications of the preparation procedure are described, including deactivation in the gas phase, and use of pentane as a solvent for static coating.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Surface deactivation, persllylation ; Discussion of variable parameters ; Suggested practical procedure ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 18 (1984), S. 197-201 
    ISSN: 1612-1112
    Keywords: Capillary GC ; Co-injection ; Solvent effects
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Co-injection techniques (introducing additional pure solvent with the sample) were tested to eliminate peak distortion due to partial solvent trapping. Co-injections of solvent identical with the sample solvent were not successful, because first only partial solvent trapping of the strong type could be eliminated and second, there was no practicable method of placing a band of pure solvent ahead of the sample in the column inlet. Successful co-injections have to accept mixing of the sample with the pure solvent. Either the solvent trapping is improved by co-injection of a solvent which enhances solution of the critical solutes in the sample layer, or it creates a phase soaking effect in the stationary phase and reconcentrates broadened bands beyond the flooded inlet. The added solvent must have the appropriate polarity and some of it must remain in the column inlet at least until the sample solvent has completely evaporated.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 366-370 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Sampling problems by syringe needle temperature ; Technical solution of the problems by cooling and heating up minimized masses ; Discrimination and standard deviation measured with test mixtures C18-C38 ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: On-column injection into a hot gas chromatograph oven involves the danger that the bottom part of the needle is warmed up above the boiling point of the solvent in the sample. Consequently parts of the sample are evaporated out of the needle instead of being introduced as a liquid into the capillary column. This causes losses and hence discrimination of the less volatile parts of the sample which remain in the needle.A technical solution is proposed using a system for cooling the capillary during the injection, down to the injection point in the oven.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 525-526 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Static coating ; Filling the column by pressure, not by vacuum ; Device for filling by pressure ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 3 (1980), S. 493-496 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Persilylation procedure ; Discussion of experimental parameters ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Persilylated glass capillary columns are the most universal GC columns available. They are relatively easy to prepare, but there is nevertheless a great need for helpful practical instructions. In the recent literature, methods and conditions for the preparation of persilylated columns have been recommended, but these might confuse the individual column maker, since they seem to originate from limited observations rather than from comprehensive investigation. They will hardly help to make column preparation safer. This paper attempts a summarized view of the present experience with persilylation and provides basic information for column makers.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 5 (1982), S. 119-123 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Static coating ; Filling with mechanical closure ; Description of an easy and safe technique ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The static technique is commonly accepted as the most universal and scientific method of coating. At the same time, however, it is said to be experimentally demanding. Great efforts have therefore been made to render the method easier and safer, resulting in a wealth of recommendations confusing non-experts. Over a period of two years we have practically applied most of the reported procedures with the aim of studying their practical convenience. We do not doubt that most procedures are comparably suitable in the hands of expert users, i. e. once the initiation efforts have been forgotten, or are otherwise of little interest. We have attempted to describe a method which is specifically suited for easy and quick introduction to beginners. The method is based on mechanical column closure. The principles of the method are discussed, and a comprehensive description of its practical application is given.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 153-155 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Immobilization of moderately polar phases ; Combination of surface bonding and crosslinking ; Vinyl groups in the support surface ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...