Co-injections to avoid peak distortion due to partial solvent trapping in capillary gas chromatography (GC)

  • Originals
  • Published:
Chromatographia Aims and scope Submit manuscript

Summary

Co-injection techniques (introducing additional pure solvent with the sample) were tested to eliminate peak distortion due to partial solvent trapping. Co-injections of solvent identical with the sample solvent were not successful, because first only partial solvent trapping of the strong type could be eliminated and second, there was no practicable method of placing a band of pure solvent ahead of the sample in the column inlet. Successful co-injections have to accept mixing of the sample with the pure solvent. Either the solvent trapping is improved by co-injection of a solvent which enhances solution of the critical solutes in the sample layer, or it creates a phase soaking effect in the stationary phase and reconcentrates broadened bands beyond the flooded inlet. The added solvent must have the appropriate polarity and some of it must remain in the column inlet at least until the sample solvent has completely evaporated.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. K. Grob Jr., J. Chromatogr.279, (1983) 225.

    Google Scholar 

  2. V. Pretorius, C. S. G. Philips, W. Bertsch, J. HRC+CC6 (1983) 232.

    Google Scholar 

  3. V. Pretorius, C. S. G. Philips, W. Bertsch, J. HRC+CC6 (1983) 273.

    Google Scholar 

  4. K. Grob Jr., J. Chromatogr.213 (1981) 3.

    Google Scholar 

  5. K. Grob Jr., J. Chromatogr.251, (1982) 235.

    Google Scholar 

  6. K. Grob Jr., B. Schilling, J. Chromatogr.264 (1983) 7.

    Google Scholar 

  7. K. Grob Jr., B. Schilling, Chromatographia17 (1983) 357 and 361.

    Google Scholar 

  8. D. R. Deans, Anal Chem.43 (1971) 2026.

    Google Scholar 

  9. R. G. Jenkins, Proc. 4th Int. Symp. on Capillary Chromatography, Hindelang 1981,R. E. Kaiser (ed.), Hüthig, Heidelberg, Basle, New York, 1981, p. 803.

    Google Scholar 

  10. E. Fogelqvist, M. Larsson, J. Chromatogr.279 (1983) 297.

    Google Scholar 

  11. J. Roeraade, S. Blomberg, Chromatographia17 (1983) 387.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Grob, K., Riekkola, M.L. Co-injections to avoid peak distortion due to partial solvent trapping in capillary gas chromatography (GC). Chromatographia 18, 197–201 (1984). https://doi.org/10.1007/BF02276732

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02276732

Key Words

Navigation