ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Analytical Chemistry and Spectroscopy  (40)
  • Engineering  (5)
  • Molecular Cell Biology  (2)
  • Wiley-Blackwell  (47)
Sammlung
Verlag/Herausgeber
  • Wiley-Blackwell  (47)
Erscheinungszeitraum
  • 1
    Digitale Medien
    Digitale Medien
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 6 (1973), S. 454-456 
    ISSN: 0029-5981
    Schlagwort(e): Engineering ; Engineering General
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Mathematik , Technik allgemein
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 23 (1986), S. 1295-1311 
    ISSN: 0029-5981
    Schlagwort(e): Engineering ; Engineering General
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Mathematik , Technik allgemein
    Notizen: This paper discusses a mathematical model governing the galvanic corrosion phenomenon and surveys the research efforts which have been applied to find a solution to the above problem. The authors classify these techniques into three categories. The first is the finite difference method (FDM), the second is the finite element method (FEM) and the last is the boundary element method (BEM).
    Zusätzliches Material: 16 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 24 (1987), S. 605-620 
    ISSN: 0029-5981
    Schlagwort(e): Engineering ; Engineering General
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Mathematik , Technik allgemein
    Notizen: This paper describes the proper external potential formulation of a cathodic protection system employed for corrosion prevention of structures in infinite electrolytes. The boundary condition associated with the mathematical formulation is not of the standard type encountered in hydrodynamic, electrostatic or heat transfer applications. The developed mathematical model is discretized by the boundary element technique, which is then solved iteratively by the Newton-Raphson method.
    Zusätzliches Material: 20 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 5 (1972), S. 91-101 
    ISSN: 0029-5981
    Schlagwort(e): Engineering ; Engineering General
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Mathematik , Technik allgemein
    Notizen: Relations form the theory of characteristics are used to connect boundary and interior points in the numerical analysis of multidimensional, unsteady gas dynamics.Since specification of all variables on the boundaries does not occur, it is necessary to employ at least some of the differential equations for boundary points. The objective is to avoid the use of non-central finite differences and the subsequent generation of a pseudo-boundary layer.Boundaries consisting of a moving shock wave, a solid wall and a surface in a supersonic, downstream region are considered. The numerical procedure for determining variables on boundaries is described in datail for the hypersonic, blunt body problem.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    ISSN: 0887-6134
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Using fast atom bombardment (FAB) ionization combined with tandem mass spectrometry (MS/MS), the identity of arsenobetaine (AB) in extracts of sole, haddock, lobster and shrimp was unequivocally confirmed. Evidence was also presented for the presence of arsenocholine (AC) in the shrimp extract. Confirmation was obtained by comparing the collision-induced dissociation (CID) daughter ion and parent ion spectra of major ions in the FAB spectra from these extracts with those from the authentic standards.
    Zusätzliches Material: 10 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 15 (1988), S. 615-621 
    ISSN: 0887-6134
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The collisionally activated decomposition of [M + H]+ ions, generated by fast atom bombardment (FAB) of glutathione conjugates, has been studied by tandem mass spectrometry (MS/MS) using hybrid sector/quadrupole instruments. Abundant fragments of diagnostic utility were present in the daughter ion spectra. Common fragmentation modes were observed but their relative importance was strongly dependent on the nature of the conjugated species. As an example of a general approach to the characterization of glutathione conjugates in biological samples, the acetaminophen-glutathione conjugate was identified in rat bile, following coadministration of (2H0)- and (2H3)acetaminophen, using the experimental sequence: (i) conventional FAB mass spectrometric analysis, (ii) MS/MS using constant neutral loss (129 u) scanning to identify parent ions corresponding to glutathione conjugates, (iii) MS/MS to yield daughter ion spectra of parents so identified and corresponding to (2H0)- and (2H3)-labeled conjugates.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Chichester [u.a.] : Wiley-Blackwell
    International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 8 (1995), S. 243-248 
    ISSN: 0894-3370
    Schlagwort(e): Engineering ; Electrical and Electronics Engineering
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: Two separate exercises on a similar theme are reported. In the first, the moment-method program NEC was extensively modified in order to optimize its performance on a four-processor Cray X-MP computer. In the second exercise, the MININEC moment-method program was completely rewritten into the occam programming language so that it could be executed directly by a transputer system. The NEC exercise exploited judicious use of vectorization and alternative parallelization techniques and achieved a reduction of run times by factors of about five or more. The MININEC exercise has so far achieved only a modest reduction in run-time but it has the potential for a much greater improvement if an optimum strategy for configuring the transputer network is implemented.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 29-32 
    ISSN: 0935-6304
    Schlagwort(e): Capillary supercritical fluid chromatography ; Injection techniques ; Reproducibility ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: An analysis of the precision obtained using commercially available microvalve injectors is reported for three modes of injection: conventional split; timed-split; and direct. Results from this study show that good precision (〈 3% RSD for external standard and 〈 1% RSD for internal standard methods) can be obtained with capillary supercritical fluid chromatography (SFC). However, particular attention must be paid to the type of valve used, the orientation of the column relative to the valve, the mode of interfacing or connecting the column to the valve, and the type of pressure or density programming used for the analysis as all of these factors will affect the reproducibility.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 10 (1987), S. 477-478 
    ISSN: 0935-6304
    Schlagwort(e): Capillary SFC ; Reproducibility ; Pump filling method ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 2 Tab.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 443-449 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography, GC ; Fused silica capillary columns ; Retention index ; Internal standards ; Environmental samples ; Dichlorobenzyl alkyl ethers ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: A homologous series of 2,4-dichlorobenzyl alkyl ethers (DCBEs) have been synthesized and purified for use as retention index calibrants and internal standards. They are stable, sensitive to ECD and FID and ideal for GC-MS, with base peaks at m/z 159/161. The retention index calibration against the n-alkanes for a linear temperature program (LTP) series is given and recommendations made for the most suitable members of the DCBE series for use as internal standards in organochlorine (OC) residue analysis.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...