ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (1)
  • Chemical Engineering  (1)
  • Wiley-Blackwell  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 17 (1977), S. 27-31 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Results of dynamic mechanical spectroscopy, infrared spectroscopy, and tensile stress-strain data show that the non-ionic surfactant Igepal CO-630, often used as a stress cracking agent, and water are absorbed by high density polyethylene to cause an internal stress relaxation of the intercrystalline tie molecules. The resulting molecular rearrangements produce changes in both the crystalline and amorphous regions. Thus, a molecular mechanism is proposed for the long-term aging process based on the results of accelerated aging in the presence of an environmental stress cracking agent.
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 0749-1581
    Keywords: Electrochemistry ; Continuous flow ; 13C NMR spectroscopy ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The anodic conversion of 2,4,6-tri-tert-butylphenol in methanol, leading to 2,4,6-tris(1,1-dimethylethyl)-4-methoxy-2,5-cyclohexadien-1-one, has been followed by two types of 13C NMR experiments: (a) a static procedure, inserting the electrodes directly into a rotating NMR tube and (b) a continuous flow procedure, combining electrochemical and NMR flow cells. During electrolysis the resolution of the 13C NMR spectra decreased in the static procedure owing to magnetic field gradients. In the flow procedure the resolution was comparable with that of routine spectra.