ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Springer  (4)
  • 1980-1984  (2)
  • 1965-1969  (2)
Collection
Years
Year
  • 1
    Publication Date: 1981-09-01
    Print ISSN: 0175-7571
    Electronic ISSN: 1432-1017
    Topics: Biology , Physics
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 1965-01-01
    Print ISSN: 0041-3763
    Electronic ISSN: 1438-1168
    Topics: Geosciences
    Published by Springer
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European biophysics journal 7 (1981), S. 317-317 
    ISSN: 1432-1017
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Mineralogy and petrology 10 (1965), S. 73-96 
    ISSN: 1438-1168
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences
    Description / Table of Contents: Summary Some experiments have been made with such materials as glass and various minerals to determine the Brewster's angle by means of a one—axis goniometer. The tube of this apparatus contains a polarizer and may be used both for microscopic and telescopic observation. A special mechanism causes the reflecting plane at any time to be perpendicular to the bisecting line between the collimator and the telescopemicroscope-tubus. By using the telescope the polarizing angle may be recognized from a black band coming into the field of vision, and by using the microscope from the intensity of light being at a minimum. This method of determination is basically independent of the number of the refractive index. It is possible to determine approximately the average refraction of the minerals in an uncovered thin rock section. Simultaneously one achieves an effect similar to dark ground illumination. Moreover, we also took quantitative measurements of light intensity by the aid of a photoelement attached to the telescope. The minimum of the intensity obtained in this way indicates the Brewster's angle. The minimum values can be derived from these curves by means of mathematical or graphical methods, but they are less accurate than the ones obtained by the aid of the black band. Disturbing effects occur e. g. as a consequence of polishing, especially of dry polishing. The limit of error is only small with planes of crystals, but quite considerable on those of glass. The obviously too high indices of reflexion for glasses could perhaps be used as a measure for the degree of high polishing. Investigations into birefringent crystals demonstrate that the two directions of vibration in conformity with the value of double refraction have different polarizing angles.
    Notes: Zusammenfassung Mit Hilfe eines Einkreisgoniometers mit senkrechter Drehachse wurde an Schliffebenen verschiedener Materialien (Glas, Minerale) der Brewstersche Winkel bestimmt. Das mit Polarisationsprismen ausgerüstete Instrument besaß einen sowohl für teleskopischen wie für mikroskopischen Strahlengang verwendbaren Tubus. Eine mechanische Einrichtung bewirkte, daß die reflektierende Fläche in jedem Augenblick senkrecht zur Winkelhalbierenden von Fernrohr und Kollimator stand. Die Erreichung des Polarisationswinkels wird teleskopisch am Auftreten eines dunklen Balkens, mikroskopisch an der minimalen Helligkeit erkannt. Diese Bestimmungsart ist von der Größe des Brechungsquotienten grundsätzlich unabhängig. Im ungedeckten Dünnschliff kann man die mittlere Lichtbrechung der Minerale annähernd bestimmen. Gleichzeitig ergibt sich eine Art Dunkelfeldbeobachtung. Mit Hilfe eines angeschlossenen Photoelementes wurden auch quantitative Messungen durchgeführt. Die erhaltenen Intensitätskurven haben ihr Minimum beim Polarisationswinkel. Die aus diesen Kurven graphisch und rechnerisch abgeleiteten Minimumwerte sind weniger genau als die durch Einstellen des dunklen Balkens bestimmten. Störeffekte entstehen unter anderem durch den Poliervorgang, insbesondere bei Trockenpolitur. Bei Kristallen ist der Fehler im allgemeinen gering, bei Gläsern hingegen meist beträchtlich. Die scheinbar höhere Lichtbrechung von Gläsern könnte vielleicht als Maß für den erzielten Hochglanz verwendet werden. Bei doppeltbrechenden Kristallen ist der Polarisationswinkel gemäß der Höhe der Doppelbrechung für die entsprechenden Schwingungsrichtungen verschieden groß.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...