ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Molecular Diversity Preservation International  (132)
  • Oxford University Press  (73)
  • American Institute of Physics (AIP)
  • American Chemical Society (ACS)
  • 2020-2022  (64)
  • 2015-2019  (163)
  • 1990-1994  (42)
  • 1955-1959  (3)
Collection
Publisher
Years
Year
  • 1
    Publication Date: 2015-07-07
    Description: Journal of Proteome Research DOI: 10.1021/acs.jproteome.5b00307
    Print ISSN: 1535-3893
    Electronic ISSN: 1535-3907
    Topics: Chemistry and Pharmacology
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 75 (1994), S. 5753-5755 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The effect of such medium properties as magnetic unit size, film thickness, and strength of anisotropy, dipolar, and exchange interactions on the storage capacity limit of a thin-film recording medium is investigated. Relationships are derived for media with different properties that have equivalent capacity. The physically realizable range of material properties and their effect on the capacity bound are explored. Results on edge effects for capacity bound computations are presented. The results indicate that media for which anisotropy is the dominant source of magnetic energy have the greatest potential for information storage.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 76 (1994), S. 1956-1958 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The nitrogen donor levels have been studied by admittance spectroscopy between 20 and 200 K in Schottky barriers made on lightly n-type epitaxial 6H-SiC layers. Measurements at different frequencies yield different freezeout temperatures which in turn are used to determine the donor level energies. Two electron traps at Ec−0.082 eV and at Ec−0.140 eV were detected. These levels are associated with nitrogen, respectively, at the hexagonal sites for the former and at the cubic sites for the latter level.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 64 (1993), S. 3530-3533 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A general purpose data acquisition and control system for scanning tunneling microscopy (STM) using Visual Basic is presented. This Windows hosted Visual Basic environment is highly desirable for use in STM image manipulation, storage, and printing, but in its standard form is not suitable for most data acquisition and display applications. Many of the inherent limitations in the Visual Basic language have been overcome by the use of direct calls to the Windows Application Program Interface. In this paper, we describe a general Visual Basic STM user interface and control system, and the extensions to the language using the Windows API needed to implement this system.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 65 (1994), S. 2416-2416 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A simple method of achieving dual scan ranges with a single piezo element in scanning probe microscope instruments is described. Both high-resolution small-scan ranges and low-resolution large-scan areas are obtainable.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 67 (1990), S. 6613-6620 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The low-velocity Barkas-effect correction term for the Bethe–Bloch stopping-power formula has been calculated with each of the three extant formalisms for targets with atomic numbers from 1 to 18 and for projectile velocities from 0.025c to 0.3c. Comparison of each with measurements on aluminum revealed which formalism provided the best fit over three different projectile velocity intervals. The method yielding the generally superior agreement was used to calculate the stopping power of each element (except Li, F, Na, Mg, P, and Cl) for protons and alpha particles with energies between 0.5 and 5.0 MeV. Results corresponded very closely to those of an existing fit to most known experimental data.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 68 (1990), S. 4917-4928 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Accurate modeling of load behavior in Z-pinch plasma radiation sources driven by high-current generators requires the measurement of fast-rise-time multimegampere currents close to the load. Conventional current diagnostics mounted in inductive cavities (such as B-dot loops and Rogowski coils) fail at small radius because of electrical breakdown produced by high dI/dt. In this paper, we describe the use of large-signal, nanosecond-time-resolution lithium niobate piezoelectric stress gauges to directly measure the magnetic pressure B2/2μ0=μ0I2/8π2r2 generated at radius r by a current I flowing in a radial transmission line. Current measurements have been performed at radius r=2.54×10−2 m on Sandia National Laboratories' Proto-II (10 TW) and SATURN (30 TW) gas puff Z-pinch experiments with maximum currents of 10.1 MA and dI/dt to 2.1×1014 A/s. Comparisons with Faraday rotation and B-dot current diagnostic measurements at large radius are presented. Bremsstrahlung noise problems unique to the SATURN gas puff source are discussed. For a Y-cut lithium niobate stress gauge on a pure tungsten electrode, current densities up to I/2πr=78 MA/m can be measured before the electrode yield strength and the piezoelectric operating stress limit are exceeded. Above the Hugoniot elastic limit of the electrode material, the dynamic range and accuracy of the diagnostic are greatly reduced, but it appears that the technique can be extended to higher current densities using an X-cut quartz piezoelectric element and a tungsten-sapphire electrode impedance stack.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 70 (1991), S. 2926-2938 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Experiments are described in which a high-purity, high-power (0.15 TW, 1 MeV) proton beam is generated from an ion source consisting of H2 gas frozen onto a liquid-helium-cooled copper anode at 4.2 K in a series-field-coil extraction diode on the 0.7 TW HydraMITE-II accelerator. Peak anode proton current densities of 2 kA/cm2 were measured. This current density is a factor of 100 higher than those obtained in previous liquid-helium-cooled cryogenic diode experiments on small accelerators and is in the range required for high-power ion beam applications. Thomson parabola, Faraday cup, and carbon activation measurements indicate an ion beam proton fraction close to 100% for the cryogenic source, compared to 50–70% for the standard hydrocarbon anode tested. The cryogenic proton source is believed to consist of no more than a few monolayers of molecular hydrogen. The hydrogen-coated cryogenic anode shows a faster initial anode turn-on than other materials. However, source-limited emission from the thin hydrogen layer results in a somewhat longer current risetime, reduced ion diode efficiency, lower proton current enhancement over the Child–Langmuir limit, and a proton spectrum of lower average energy than for the hydrocarbon anode. Techniques to overcome these limitations are discussed. Cryogenic ion sources consisting of frozen N2, CH4, and Ne have also been studied. In each case, high intensity beams consisting predominantly of components of the refrigerated gas were produced.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 63 (1992), S. 5703-5706 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A reliable sodium wire-array z-pinch load has been developed for use on the Saturn accelerator. This load routinely produces implosions with ≥200 GW of power in the heliumlike sodium 1s2–1s2p 1P1 line at 11 A(ring). Our best shots have used a 12.5-mm-diam, 20-mm-long annular array of 16 75-μm-diam pure sodium wires. This load will allow us to test predictions of gain in the sodium/neon resonant photoexcitation x-ray laser system.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Experiments to explore the long-time evolution of noninductive, high βp plasmas in the DIII-D tokamak [Plasma Physics and Controlled Nuclear Fusion Research, 1986 (International Atomic Energy Agency, Vienna, 1987), Vol. 1, p. 159], have identified a new, quiescent, high performance regime. The experiments were carried out at low current (400–800 kA) with medium power neutral beam injection (3–10 MW). This regime is characterized by high q0 ((approximately-greater-than)2) and moderate li(∼1.3). It is reached by slow relaxation of the current profile, on the resistive time scale. As the profiles relax, q0 rises and li falls. When q0 goes above 2 (approximately), magnetohydrodynamic (MHD) activity disappears, and the stored energy rises. Most dramatic is the strong peaking of the central density, which increases by as much as a factor of 2. The improved central confinement appears similar to the PEP/reversed central shear/second stable core modes seen in tokamak experiments, but in this case without external intervention or transient excitation. At high current, a similar, but slower relaxation is seen. Also notable in connection with these discharges is the behavior of the edge and scrape-off layer (SOL). The edge localized modes (ELM's) as seen previously, are small and very rapid (to 1 kHz). The SOL exhibits high density (≥1×1019 m−3), which shows little or no falloff with radius. Also the power deposition at the divertor surface is very broad, up to four times the width usually seen. This regime is of particular interest for the development of steady-state tokamak operating scenarios, for the Tokamak Physics Experiment (TPX), and following reactors.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...