ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2010-2014  (166,855)
  • 1975-1979  (49,005)
  • 1945-1949  (4,058)
Collection
Language
Years
Year
  • 1
    Call number: SR 90.1043(106)
    In: Illinois petroleum
    Type of Medium: Series available for loan
    Pages: 12 S.
    Series Statement: Illinois petroleum 106
    Language: English
    Location: Lower compact magazine
    Branch Library: GFZ Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Call number: K-13-0039
    Branch Library: AWI Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Series available for loan
    Series available for loan
    Washington, DC : United States Gov. Print. Off.
    Associated volumes
    Call number: SR 90.0002(1024)
    In: Professional paper
    Type of Medium: Series available for loan
    Pages: VI, 203 S. + 4 pl.
    Series Statement: U.S. Geological Survey professional paper ;1024
    Language: English
    Location: Lower compact magazine
    Branch Library: GFZ Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Series available for loan
    Series available for loan
    Hanover, NH : U.S. Army Cold Regions Research and Engineering Laboratory
    Associated volumes
    Call number: ZSP-201-78/26
    In: CRREL Report, 78-26
    Description / Table of Contents: Ice fog suppression experiments on the Fort Wainwright Power Plant cooling pond were conducted during the winters of 1974-76. Baseline information studies occupied a sizable portion of the available ice fog weather in 1974-75. Then hexadecanol was added to the pond and dramatically improved visibility by reducing fog generated from water vapor released by the pond at -14 C. Although this temperature was not low enough to create ice fog, the cold vapor fog created was equally as devastating to visibility in the vicinity of the pond. During the winter of 1975-76, suppression tests were continued using films of hexadecanol, mixes of hexadecanol and octadecanol, and ethylene glycol monobutyl ether (EGME). Suppression effectiveness at colder temperatures was stuided and limits to the techniques were probed. A reinforcing grid was constructed that prevented breakup of the film by wind and water currents. Lifetime tests indicated that EGME degrades much more slowly than either hexadecanol or the hexadecanol-octadecanol mix. The films were found to be very effective fog reducers at warmer temperatures but still allowed 20% to 40% of normal evaporation to occur. The vapor thus produced was sufficient to create some ice fog at lower temperatures, but this ice fog occurred less frequently and was more quickly dispersed than the thick fog that was present before application of the films.
    Type of Medium: Series available for loan
    Pages: iv, 27 Seiten , Illustrationen
    Series Statement: CRREL Report 78-26
    Language: English
    Note: CONTENTS Abstract Preface Introduction Ice fog from cooling ponds Evaporation Relative humidity and cold air Ice fog suppression Air movement Plastic films Rafts Injection wells Cooling towers Chemical films Reinforced film experiments Meteorological data collection Floating reinforcement grid Application of the hexadecanol film Hexadecanol, octadecanol mixes Ethylene glycol monobutyl ether Laboratory tests of suppression effectiveness Conclusions Literature cited Appendix A. Design for an automatic thin chemical film applicationsystem Appendix B. Meteorological data
    Location: AWI Archive
    Branch Library: AWI Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Call number: ZSP-201-77/9
    In: CRREL Report, 77-9
    Description / Table of Contents: This report presents experimental results on the conditions of initiation of an ice jam by a simple surface obstruction, on the equilibrium thickness of an ice jam formed by accumulation and submergence of ice floes, and on the compression strength of floating, fragmented ice cover. In the study on ice jam initiation, it was found that the minimum concentration of floes in the opening of the obstruction at which a jam occurs is nearly independent of the ratio of width of constricted passage to channel width, and is proportional to a negative power of the ratio of floe length to width of constricted passage. From energy analysis of floe submergence, a relationship relating the thickness of a jam formed by accumulation and submergence of floes to the approach flow characteristics was derived and found to fit satisfactorily the experimental data. In experiments on compression strength of floating, fragmented ice cover it was found that the compressive strength is inversely proportional to compression velocity and independent of cover length.
    Type of Medium: Series available for loan
    Pages: vii, 45 Seiten , Illustrationen
    Series Statement: CRREL Report 77-9
    Language: English
    Note: CONTENTS Abstract Preface List of symbols Introduction I. Initiation of ice jams by partial surface obstructions A. Introductory remarks B. Experimental apparatus and procedure C. Dimensional analysis D. Presentation of results and discussion ΙΙ. Thickness of ice jams due to accumulation and transport of ice floes A. Introductory remarks B. Experimental apparatus and procedures C. Presentation of results E. Conclusion III. Compressive strength of floating fragmented ice covers A. Introductory remarks B. Experimental setup and procedure C. Presentation of results and discussion D. Conclusions Literature cited Appendix A: Experimental results on ice jam initiation Appendix B: Effect of surface tension on submergence velocity of ice floes Appendix C: Experimental results for ice jam thickness study Appendix D: Experimental results on compressive strength of fragmented ice cover
    Location: AWI Archive
    Branch Library: AWI Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Series available for loan
    Series available for loan
    Hanover, NH : U.S. Army Cold Regions Research and Engineering Laboratory
    Associated volumes
    Call number: ZSP-201-79/3
    In: CRREL Report, 79-3
    Type of Medium: Series available for loan
    Pages: ii, 7 Seiten , Illustrationen
    Series Statement: CRREL Report 79-3
    Language: English
    Location: AWI Archive
    Branch Library: AWI Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Monograph available for loan
    Monograph available for loan
    Wageningen : Centre for Agricultural Publ. and Documentation
    Call number: PIK M 370-91-0161 ; MOP 44707 / Mitte
    Type of Medium: Monograph available for loan
    Pages: 175 Seiten , Illustrationen
    Edition: 2., revised and extended edition
    ISBN: 9022006522
    Series Statement: Simulation monographs
    Language: English
    Note: Contents 1 Introduction 1.1 Purpose 1.2 Some terminology 1.3 Electrical analogues 1.4 State determined systems 1.5 Simulation languages 2 Exponential growth 2.1 Analytical and numerical integration 2.2 Simulation 2.3 Time constant and time interval of integration 2.4 Integration method and time interval 3 The growth of yeast 3.1 Description of the system 3.2 Relational diagrams 3.3 Simulation 3.4 Logistic growth 4 Interference of plants 4.1 Replacement series 4.2 Density of sowing 4.3 Simulation of plant interference 4.4 Further modelling aspects 4.4.1 The INDEX and MACRO feature 4.4.2 The INITIAL and DYNAMIC section 5 Growth and competition of Paramecium 5.1 Description of the system 5.2 A simulation program 5.3 Preliminary estimation of parameters 5.4 Final determination of parameters 5.5 Stochastic aspects 5.6 The programming of probability functions 6 Modelling of development, dispersion and diffusion 6.1 Introduction 6.2 Physiological age and development stage 6.3 Demographic models 6.3.1 Age-classes 6.3.2 Errors of approximation 6.3.3 The matrix method 6.4 Germination models 6.4.1 Boxcar train without dispersion 6.4.2 Boxcar train with constant relative dispersion 6.4.3 Boxcar train with controlled dispersion 6.4.4 Refinements 6.5 The flow of heat in soils 7 Growth and development of Helminthosporium maydis 7.1 Introduction 7.2 The weather 7.3 Appearance and growth of lesions 7.4 Sporophore or stalk formation 7.5 Sporulation of green stalks 7.6 Sporulation of dried stalks 7.7 Dispersal of spores 7.8 Germination of spores and penetration of germtubes 7.9 Timing, initialization and output organization 7.10 Results and sensitivity analyses 8 Population models for fruit-tree red spider miteand predatory mites 8.1 Fruit-tree red spider mite 8.2 Predatory mite, Amblyseius potentillae 8.3 Relations between predator and prey 8.4 Preference as a competitive process 8.5 Verification 9 Solutions of the exercises References Appendix A Appendix B Index
    Location: A 18 - must be ordered
    Location: MOP - must be ordered
    Branch Library: PIK Library
    Branch Library: GFZ Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Call number: MOP 44919 / Mitte
    Type of Medium: Monograph available for loan
    Pages: 142 S. : graph. Darst.
    Location: MOP - must be ordered
    Branch Library: GFZ Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Series available for loan
    Series available for loan
    Hanover, NH : U.S. Army Cold Regions Research and Engineering Laboratory
    Associated volumes
    Call number: ZSP-201-77/11
    In: CRREL Report, 77-11
    Description / Table of Contents: Two performance indicators, effectiveness and thermal efficiency, are defined and used to evaluate the year-round performance of three protected membrane roofs in Alaska and New Hampshire. Effectiveness is a measure of the deviations of ceiling temperatures from a yearly average, with large diviations indicating erratic performance in the roofing-insulation system and small departures indicating a thermally stable system. Thermal efficiency, the ratio of calculated heat loss to measured heat loss, is affected by climatic conditions such as rain, snow, solar radiation and wind. Thermal efficiency values of 100% or greater are possible since the calculated heat loss is based only on the inside and outside air temperature differences and the thermal properties of the roof components. Results of the year-round evaluation indicate that the three protected membrane roofs generally have high values of both effectiveness and thermal efficiency.
    Type of Medium: Series available for loan
    Pages: v, 40 Seiten , Illustrationen
    Series Statement: CRREL Report 77-11
    Language: English
    Note: CONTENTS Abstract Preface Conversion factors: U.S.customary to metric (SI) units of measurement Introduction Location of test sites Fairbanks Anchorage Hanover, N.H. Test program Instrumentation Effectiveness Therma lefficiency Heat balance within the roof Comparisons with conventional systems Conclusions Effectiveness of the test roof Thermal efficiency Heat balance within the roof Applicability Recommendations Literature cited Appendix A. Temperature and heat flow measurements, Anchorage and Fairbanks, Alaska, and Hanover, New Hampshire Appendix B. Thermal efficiencies of the test roof, Anchorage and Fairbanks, Alaska, and Hanover, New Hampshire Appendix C. January 1973 and August 1972 comparisons of protected membrane and conventional built-up membrane systems at Hanover, New Hampshire
    Location: AWI Archive
    Branch Library: AWI Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Call number: ZSP-201-78/9
    In: CRREL Report, 78-9
    Description / Table of Contents: Large, simply supported beams of temperate lake ice were found, generally, to yield significantly higher flexural strengths than the same beams tested in the cantilever mode. Data support the view that a significant stress concentration may exist at the fixed corners of the cantilever beams. Maximum effects are experienced with beams of cold, brittle ice substantially free of structural imperfections; for this kind of ice the strength difference factor, here attributed to the effect of stress concentrations, may exceed 2.0; that is, simply supported beams test a factor of 2 or more stronger than the same beams tested in the cantilever mode. In ice that has undergone extensive thermal degradation, the stress concentration effect may be eliminated entirely. Simply supported beams generally yield higher strengths when the top surfaces are placed in tension. This behavior is attributed to differences in ice type; the fine-grained, crack-free top layer of snow-ice which constituted up to 50% of the ice cover in the current series of tests usually reacted more strongly in tension than the coarse-grained crack-prone bottom lake ice.
    Type of Medium: Series available for loan
    Pages: iv, 14 Seiten , Illustrationen
    Series Statement: CRREL Report 78-9
    Language: English
    Note: CONTENTS Abstract Preface Introduction Test sites and ice cover properties Beam testing Results Discussion Conclusions Literature cited
    Location: AWI Archive
    Branch Library: AWI Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...