ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (123)
Collection
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 109 (1987), S. 1746-1754 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1424
    Keywords: atrium ; sinus venosus ; pacemaker ; inward rectifier ; impedance ; isolated cardiac cells ; linear analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Summary Single electrode whole cell voltage-clamp experiments and frequency domain analyses have been used to study and compare the K+ currents in enzymatically dispersed single cells from the atrium and the sinus venosus (pacemaker region) of the bullfrog heart. Admittance measurements made near the ‘resting’ or zero-current potential yield data from which the equivalent circuit of each cell type may be obtained. Data from both atrial and pacemaker cells are well-fitted by a model consisting only of parallel resistance-capacitative elements, as predicted from their micro-anatomy. Neither of these amphibian cardiac cells contain a transverse tubule system (TT) and both have very little sarcoplasmic reticulum (SR). These results complement and extend two earlier investigations: (i) Moore, Schmid and Isenberg (J. Membrane Biol. 81:29–40, 1984) have reported that in guinea pig ventricle cells (whichdo contain an internal membrane system consisting of transverse tubules and a substantial SR) the SR may be electrically coupled to the sarcolemma; (ii) Shibata and Giles (Biophys. J. 45:136a, 1984) have shown that although bullfrog atrial cells have an inwardly rectifying back-ground K+ current, $$I_{K_1 } $$ , pacemaker cells from the immediately adjacent sinus venosus do not. Data from admittance measurements also provide evidence that a TTX-insensitive inward Ca2+ current is activated in the pacemaker range of potentials.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 36 (1989), S. 357-360 
    ISSN: 1432-1041
    Keywords: salbutamol ; asthma ; metabolism ; potassium ; glucose
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary We have studied the biochemical effects of high doses of inhaled salbutamol in 14 asthmatic patients age 38 years, FEV1 62%. Cumulative doubling doses of inhaled salbutamol were given every 20 min as follows: 100 µg, 200 µg, 500 µg, 1000 µg, 2000 µg, 4000 µg. Plasma glucose, potassium, and magnesium were measured at each step of the doseresponse curve. Salbutamol produced significant hypokalaemic and hyperglycaemic effects, but no significant change in magnesium. There were linear log-dose responses for both glucose (r/it=0.58) and potassium (r=−0.46). There were wide individual variations in maximum responses to salbutamol 4000 µg (as means and 95% confidence intervals): Δ glucose 1.46 (0.83 to 2.09) mmol/l, Δ potassium −0.38 (−0.64 to −0.12) mmol/l. Thus, hypokalaemic and hyperglycaemic effects may occur with doses of salbutamol similar to those curently used for nebulizer therapy (2.5–5 mg). We postulate that during acute exacerbations of airflow obstruction these changes may be accentuated and become clinically relevant.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-1041
    Keywords: salbutamol ; sublingual ; oral ; inhaled ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Administration of drugs by the sublingual route provides rapid systemic absorption and avoids first-pass metabolism. The purpose of the present study was to assess the pharmacokinetics, efficacy and adverse effects of standard salbutamol tablets given by this route to patients with asthma. Seven asthmatic patients were given either sublingual salbutamol tablet 2 mg (SL), swallowed tablet 2 mg (O), metered dose inhaler 200 µg (MDI) or placebo (PL), in a randomized single-blind cross-over design. Airways responses (FEV1, FVC, PEFR), finger tremor (Tr), heart rate (HR), plasma potassium (K) and plasma salbutamol were measured over a 6 h period following drug administration. There were highly significant changes in FEV1 with MDI, O and SL routes compared with PL, although the response to MDI was greater and more rapid than with O or SL. There were similar findings for FVC and PEFR responses. There were no adverse effects with MDI, whereas both 0 and SL produced significant tremor responses. There were no differences between O and SL for any of the pharmacodynamic parameters. In addition, pharmacokinetic profiles for O and SL were also similar apart from an initial delay in absorption with SL. There were however, no significant differences in any of the pharmacokinetic parameters, between O and SL. This suggests that buccal absorption of salbutamol was negligible, and that systemic absorption occurred after swallowing of the dissolved sublingual tablet. These results show that sublingual administration of salbutamol tablet has no clinical benefit over the oral route.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-1041
    Keywords: salbutamol ; asthma ; controlled-release formulation ; pharmacokinetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary Fifteen patients with asthma were given salbutamol controlled-release (SCR) 4 mg or 8 mg twice daily for seven days, in a randomised double-blind cross-over design. Plasma salbutamol levels were measured after the first and fifteenth doses for a 12 h period following drug ingestion. At steady-state the geometric mean values for Cmax were 8.2 ng/ml for 4 mg, and 16.1 ng/ml for 8 mg. Median tmax values were 300 and 240 min respectively. The geometric mean AUC (0–12) were 4507 ng·min·ml−1 and 8980 ng·min/ml. Peak to trough fluctuation ratios were 0.577 and 0.572. There were no significant differences between 4 mg or 8 mg formulations, for any of the parameters measured, after appropriate corrections for dose. The concentration-time profiles at steady-state showed little fluctuation in plasma salbutamol levels over the twelve hour dosing interval. These results show that 4 mg and 8 mg formulations of SCR provide smooth plasma profiles at steady-state with a twice daily dosing regime.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Physics of Fluids 29 (1986), S. 1971-1978 
    ISSN: 1089-7666
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The implosion dynamics of a hollow cylindrical neon gas-puff plasma are investigated using a 1-D non-local thermodynamic equilibrium radiation hydrodynamic model. Two cases are considered: the implosion of the gas puff with and without a low-density central core plasma. It is shown that the implosion efficiently converts the kinetic energy of runin into radiation and that the radiation plays a significant role in the implosion energetics. For each case, the history of the implosion dynamics and emission spectra are presented as well as the distribution of radiative energy in the L and K shells. Finally, a comparison is made with purely hydrodynamic calculations.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 63 (1988), S. 997-1008 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The electron beam in a linear induction accelerator is generally susceptible to growth of the transverse beam breakup instability. In this paper we analyze a new technique for reducing the transverse coupling between the beam and the accelerating cavities, thereby reducing beam breakup growth. The basic idea is that the most worrisome cavity modes can be cutoff by a short section of coaxial transmission line inserted between the cavity structure and the accelerating gap region. We have used the three-dimensional simulation code SOS to analyze this problem. In brief, we find that the technique works, provided that the lowest TE mode cutoff frequency in the coaxial line is greater than the frequency of the most worrisome TM mode of the accelerating cavity.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A new, large-area, high-uniformity, flash x-ray source that efficiently couples electrical energy to photon energy has been successfully constructed and tested on the 1-MV, 2-MA electron accelerator SPEED (short pulse experimental electron device). The source employs 18 individual blade diodes arranged in the configuration of a frustum. Each blade was magnetically isolated on the real-cathode side of an anode foil, but not on the virtual-cathode side. The operation of the diode was heavily diagnosed using 24 Rogowski coils, a vacuum voltage monitor, p-i-n diode detectors, an 80-element TLD array, and a fast-framing x-ray pinhole camera. The individual blade diodes were found to exhibit line pinching, end-to-end pinching, and minimal electron reflexing through the Ta anode foil, with a radiation yield that agreed with Monte Carlo simulations. The end-to-end pinch location could be controlled by tapering the anode–cathode gap. The impedance depended on only the smallest spacing, and was independent of pinch location.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 455 (1985), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 455 (1985), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...