ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Other Sources  (6)
  • 2010-2014  (4)
  • 1985-1989  (2)
Collection
Years
Year
  • 1
    Publication Date: 2019-06-28
    Description: An existing cold-jet facility at NASA Lewis Research Center was modified to produce swirling flows with controllable initial tangential velocity distribution. Two extreme swirl profiles, i.e., one with solid-body rotation and the other predominated by a free-vortex distribution, were produced at identical swirl number of 0.48. Mean centerline velocity decay characteristics of the solid-body rotation jet flow exhibited classical decay features of a swirling jet with S - 0.48 reported in the literature. However, the predominantly free-vortex distribution case was on the verge of vortex breakdown, a phenomenon associated with the rotating flows of significantly higher swirl numbers, i.e., S sub crit greater than or equal to 0.06. This remarkable result leads to the conclusion that the integrated swirl effect, reflected in the swirl number, is inadequate in describing the mean swirling jet behavior in the near field. The relative size (i.e., diameter) of the vortex core emerging from the nozzle and the corresponding tangential velocity distribution are also controlling factors. Excitability of swirling jets is also investigated by exciting a flow with a swirl number of 0.35 by plane acoustic waves at a constant sound pressure level and at various frequencies. It is observed that the cold swirling jet is excitable by plane waves, and that the instability waves grow about 50 percent less in peak r.m.s. amplitude and saturate further upstream compared to corresponding waves in a jet without swirl having the same axial mass flux. The preferred Strouhal number based on the mass-averaged axial velocity and nozzle exit diameter for both swirling and nonswirling flows is 0.4.
    Keywords: AERODYNAMICS
    Type: NASA-CR-180895 , NAS 1.26:180895
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2019-06-28
    Description: Miniature, high-frequency, pressure transducers were mounted on a pusher propeller at 3/4 and 90-percent radii. Time-history of fluctuating surface pressure over 700 revolutions and 26 flight conditions reveal intriguing phenomena. The anticipated pylon wake signature manifests itself as a negative pressure pulse over extended portions of the suction surface. The phenomenon further develops into a primarily random turbulence signature at 80-percent chord and interestingly may reevolve as a coherent wake signature further downstream. A new type of periodic disturbance of long time-scale, compared to propeller period-of-revolution, is discovered at positions beyond 0.6 chord on the suction surface in the transonic regime.
    Keywords: ACOUSTICS
    Type: AIAA PAPER 89-2052
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-07-19
    Description: Prolonged weightlessness is associated with declines in musculoskeletal, cardiovascular, and sensorimotor health. Consequently, in-flight countermeasures are required to preserve astronaut health. We developed and tested a novel exercise countermeasure device (CCD) for use in spaceflight with the aim of preserving musculoskeletal and cardiovascular health along with an incorporated balance-training component. Additionally, the CCD features a compact footprint, and a low power requirement. Methods: After design and development of the CCD, we carried out a training study to test its ability to improve cardiovascular and muscular fitness in healthy volunteers. Fourteen male and female subjects (41.4+/-9.0 years, 69.5+/-15.4Kg) completed 12 weeks (3 sessions per week) of concurrent strength and endurance training on the CCD. Subjects were tested at baseline and after 12 weeks for 1-repetition max leg press strength (1RM), peak oxygen consumption (VO2peak), and isokinetic joint torque (ISO) at the hip, knee, and ankle. Additionally, we evaluated subjects after 6 weeks of training for changes in VO2peak and 1RM. Results: VO2peak and 1RM improved after 6-weeks, with additional improvements after 12 weeks (1.95+/-0.5, 2.28+/-0.5, 2.47+/-0.6 LY/min and 131.2+/-63.9,182.8+/-75.0, 207.0+/-75.0 Kg) for baseline, 6 weeks, and 12 weeks respectively. ISO for hip adduction, adduction, and ankle plantar flexion improved after 12 weeks of training (70.3+/-39.5, 76.8+/-39.2 and 55.7+/-21.7 N-m vs. 86.1+/-37.3, 85.1+/-34.3 and 62.1+/-26.4 N-m respectively). No changes were observed for ISO during hip flexion, knee extension, or knee flexion. Conclusions: The CCD is effective at improving cardiovascular fitness and isotonic leg strength in healthy adults. Further, the improvement in hip adductor and abductor torque provides support that the CCD may provide additional protection for the preservation of bone health at the hip.
    Keywords: Aerospace Medicine
    Type: JSC-CN-21987
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2019-07-13
    Description: During extended periods of skeletal unloading, losses in strength and density of the proximal femur will occur. In long-duration spaceflight, resistive exercise is used to replace the normal loads exerted on the spine and hip. At the present time, there is no conclusive evidence that hip bone loss has been prevented in this scenario. Our group has recently developed and clinically evaluated a multifunctional exercise system, the Combined Countermeasure Device (CCD). The CCD comprises a low-footprint Stuart Platform for lower-body resistance exercise and balance training, and a cardiovascular exercise bicycle. A consideration for resistance exercise was targeting of the hip abductor and adductor muscles, which attach directly at the hip and which should subject it to the largest loads. In our training study, we found that CCD exercise increased hip adductor and abductor strength, and modeling results suggest that this exercise exerts forces on the hip of approx. 4-6 body weights at 1g, compared to forces of approx.2.5 body weight y squatting exercise. In our current study, we hypothesize that abductor and adductor exercise will increase the density and strength of the proximal femur.
    Keywords: Aerospace Medicine
    Type: JSC-CN-25294 , 2012 NASA Human Research Program Investigators'' Workshop; Feb 14, 2012 - Feb 16, 2012; Houston, TX; United States
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2020-11-02
    Description: Supercritical carbon dioxide (SC-CO2) extraction of lipid from Scenedesmus sp. for biodiesel production was investigated and compared to conventional extraction methods. The effect of biomass pre-treatment prior to extraction and extracting conditions, namely pressure in the range of 200–500 bar, temperatures in the range of 35–65 °C and CO2 flow rate in the range of 1.38–4.02 g min−1, on SC-CO2 extraction yield and quality of lipid were investigated. Three levels full factorial design of experiments and response surface methodology was used to model the system. A second order polynomial model was developed and used to predict the optimum conditions. Scaling up to a laboratory larger scale was also tested. The results indicated that SC-CO2 extraction was superior to other extraction techniques, but exhibited significant variations in yield with changes in operating parameters. In the developed model, it was found that the linear and quadratic terms of the temperature, as well as the interaction with pressure had a significant effect on lipid yield; whereas, their effect on lipid quality was insignificant. The best operating conditions, in the tested range, were 53 °C, 500 bar and 1.9 g min−1, in which lipid extraction yield of 7.41% (dry weight basis) was obtained. Negligible differences were observed when the fatty acid composition of SC-CO2 extracted lipid was compared to that extracted by the conventional methods. At the optimum conditions, SC-CO2 extraction was successfully scaled-up by eight-folds and the extracted lipid yield dropped by 16%.
    Type: Article , PeerReviewed
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    facet.materialart.
    Unknown
    Centre for Ecology and Hydrology
    In:  Climate Change and Irrigation: Global Impacts and Regional Feedbacks | WATCH technical report ; 47
    Publication Date: 2022-03-21
    Type: info:eu-repo/semantics/report
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...