ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Industrial & engineering chemistry 29 (1937), S. 394-397 
    ISSN: 1520-5045
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 1937-04-01
    Print ISSN: 0019-7866
    Electronic ISSN: 1541-5724
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    facet.materialart.
    Unknown
    In:  EPIC3Physics of ice core records II / ed. by Takeo Hondoh Sapporo : Hokkaido University Press. (Low Temperature Science, Supplement Issue ; 68), 39, ISSN: 1880-7593
    Publication Date: 2019-07-17
    Repository Name: EPIC Alfred Wegener Institut
    Type: Conference , notRev
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 71 (2000), S. 836-838 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: For the International Fusion Materials Irradiation Facility (IFMIF) scenario, a 140 mA deuterium beam in continuous wave (cw) mode with an atomic yield of above 85% is required. The normalized root-mean-square emittance should be less than 0.2 π mm mrad at the entrance of a RFQ. As part of a conceptual design for IFMIF, a new ion source has been developed and is tested at the Institut für Angewandte Physik in Frankfurt. The ion source is of the volume type with a tungsten cathode driving the discharge. Both cw and pulsed mode are possible and were studied. First experiments were carried out with deuterium. 80 mA deuterons with a D+ fraction of above 90% were extracted [A. Maser et al., Rev. Sci. Instrum. 67, 1054 (1996)]. In order to avoid neutron generation by the d–d reaction, hydrogen was used instead of deuterium later on. As far as the ion source and plasma production processes are concerned, the use of hydrogen instead of deuterium is equivalent because of their similar atomic shells. Recently, a 200 mA proton beam at 55 kV was extracted in cw mode (according to Child–Langmuir, 200 mA H+ corresponds to 140 mA D+) with a H+ fraction of 93%. This article will give a detailed description of the ion source and the essential experimental results. Especially, the influence of important physical parameters (such as discharge current and strength of the filter field) on the H+ fraction was studied. By using different kinds of auxiliary gases, the influence on the H+ fraction and the noise level were investigated, too. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 73 (2002), S. 1027-1029 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: For the International Fusion Materials Irradiation Facility project (IFMIF) the Institut für Angewandte Physik at the University of Frankfurt is concerned with developing a high current proton/deuteron ion source. The 1999 "Frankfurt 200 mA Proton Source" is a volume type belonging to the high-efficient ion-sources family. This type of ion source has proven its capability to produce high-current ion beams of a single mass-to-charge ratio at very low-beam emittances. The arc discharge ion source delivers a 200 mA full beam (93% protons) at 55 keV with very high-beam intensities (outlet aperture 8 mm diam). Thus, the beam requirements for the IFMIF project are fulfilled. After having done the basic plasma investigation with a 127° cylinder spectrometer, the quality of the ion beam was a point of interest. Therefore, the beam emittance was measured with a conventional slit-grid measurement device. The goal was to measure the beam emittance at high-beam currents. The article will give a detailed description of the measurement of a 56 mA beam at 26 keV with 85% protons. Theoretical considerations of the emittance value, given by ion temperature and aberrations of the extraction system, allows an estimation of the emittance of a 170 mA at 55 keV proton beam. In a second step, an estimation of a postaccelerated 140 mA at 100 keV deuteron beam was completed. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 33 (2000), S. 1162-1174 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: The instrumental transparency functions of five commercially available texture goniometers were measured experimentally with six monocrystalline samples cut in different orientations from a large highly perfect silicon crystal with a rocking curve of less than 0.01°. Transparency functions were measured in steps of 0.02 to 0.2° in the pole-figure angles α, β. The window size Δα depends on the Bragg angle θ in the form 1/sinθ; the window size Δω is constant for each goniometer. The dominant instrumental parameter determining the long axis Δα of the pole-figure window is the axial width of the detector entrance slit. This parameter is smallest for area detectors (smaller by more than an order of magnitude compared with conventional scintillation detectors as well as one-dimensional position-sensitive detectors). The main features of the pole-figure window and their dependence on the instrumental parameters can be deduced fairly well from a simple geometrical model. The particular shapes of the transparency functions of the studied goniometers are markedly different. Particularly, they are not very well represented by Gauss functions. The two-dimensional transparency function can be fairly well characterized by its α and β profiles. The normalized profiles are virtually independent of the goniometer angles 2θ and α. The increasing size of the pole-figure window with decreasing θ puts a lower limit on the Bragg angle below which pole-figure measurement ceases to be meaningful.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 8 (2000), S. 157-160 
    ISSN: 1434-601X
    Keywords: PACS 21.10.Pc Single-particle levels and strength function – 23.20.Lv Gamma transitions and level energies – 25.55.-e 3H-, 3He-, and 4He-induced reactions
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract: Single-particle states as well as collective states in the natural Bismuth isotope 209Bi were investigated using two EUROBALL CLUSTER detectors at the Cologne FN-tandem accelerator. The states were populated by the subcoulomb proton stripping reaction 208Pb He,d 209Bi at 20.5 MeV beam-energy. Forty-eight -transitions and 33 levels were observed for the first time. Gamma-transitions up to an energy of 6.0 MeV were detected. The energy of the observed states were determined to an accuracy of about 0.3 keV.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 14 (2000), S. 371-376 
    ISSN: 1434-6036
    Keywords: PACS. 61.16.Ch Scanning probe microscopy: scanning tunnelling, atomic force, scanning optical, magnetic force, etc. - 68.35.Bs Surface structure and topography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract: We report here a preparation for thin gold films on mica substrates. We have investigated the influence of the substrate temperature and the evaporation rate on the morphology of the films. After careful outgasing of the substrate, 100 nm of Au is evaporated onto the mica surface maintained at high temperature. After slow cooling, ex situ characterizations are performed using AFM and STM. For our purposes, the best compromise between roughness and grain size is found to occur for an evaporation rate of 2 Ås-1 onto a mica substrate maintained at 460 C. We have used these substrates for STM and AFM study of decanethiol self-assembled monolayers (SAMs). We present results for gold samples immersed for a few seconds in decanethiol solutions, revealing an incomplete organization of the films. The organization process is discussed through comparison between AFM and STM data recorded on the SAMs. Then we present molecular resolution STM pictures of ordered SAMs for longer immersion times.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    facet.materialart.
    Unknown
    In:  Geological Society Special Publication 319: 161-170.
    Publication Date: 2009-07-27
    Description: The grain sizes of gas hydrate crystallites are largely unknown in natural samples. Single grains are hardly detectable with electron or optical microscopy. For the first time, we have used high-energy synchrotron diffraction to determine grain sizes of six natural gas hydrates retrieved from the Bush Hill region in the Gulf of Mexico and from ODP Leg 204 at the Hydrate Ridge offshore Oregon from varying depth between 1 and 101 metres below seafloor. High-energy synchrotron radiation provides high photon fluxes as well as high penetration depth and thus allows for investigation of bulk sediment samples. Gas hydrate grain sizes were measured at the Beam Line BW 5 at the HASYLAB/Hamburg. A moving area detector method', originally developed for material science applications, was used to obtain both spatial and orientation information about gas hydrate grains within the sample. The gas hydrate crystal sizes appeared to be (log-)normally distributed in the natural samples. All mean grain sizes lay in the range from 300 to 600 {micro}m with a tendency for bigger grains to occur in greater depth. Laboratory-produced methane hydrate, aged for 3 weeks, showed half a log-normal curve with a mean grain size value of c. 40 {micro}m. The grains appeared to be globular shaped.
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...