ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Astrophysics  (35)
  • Chemical Engineering  (8)
  • Geophysics
  • 2015-2019  (35)
  • 1975-1979  (8)
  • 1
    Publication Date: 2019-07-13
    Description: An inexpensive, laboratory-based, strain gauge valve gape monitor (SGM) was developed to monitor the valve gape behavior of bivalve molluscs in response to diel-cycling hypoxia. A Wheatstone bridge was connected to strain gauges that were attached to the shells of oysters (Crassostrea virginica). The recorded signals allowed for the opening and closing of the bivalves to be recorded continuously over two-day periods of experimentally-induced diel-cycling hypoxia and diel-cycling changes in pH. Here, we describe a protocol for developing an inexpensive strain gauge monitor and describe, in an example laboratory experiment, how we used it to measure the valve gape behavior of Eastern oysters (C. virginica), in response to diel-cycling hypoxia and cyclical changes in pH. Valve gape was measured on oysters subjected to cyclical severe hypoxic (0.6 mg/L) dissolved oxygen conditions with and without cyclical changes in pH, cyclical mild hypoxic (1.7 mg/L) conditions and normoxic (7.3 mg/L) conditions. We demonstrate that when oysters encounter repeated diel cycles, they rapidly close their shells in response to severe hypoxia and close with a time lag to mild hypoxia. When normoxia is restored, they rapidly open again. Oysters did not respond to cyclical pH conditions superimposed on diel cycling severe hypoxia. At reduced oxygen conditions, more than one third of the oysters closed simultaneously. We demonstrate that oysters respond to diel-cycling hypoxia, which must be considered when assessing the behavior of bivalves to dissolved oxygen. The valve SGM can be used to assess responses of bivalve molluscs to changes in dissolved oxygen or contaminants. Sealing techniques to better seal the valve gape strain gauges from sea water need further improvement to increase the longevity of the sensors.
    Keywords: Astrophysics
    Type: GSFC-E-DAA-TN54019 , Journal of Visualized Experiments (e-ISSN 1940-087X); 138
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 18 (1978), S. 527-532 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Filaments of ultra-oriented high density polyethylene were solid-state extruded at an extrusion (draw) ratio of 26 and subsequently irradiated under vacuum by a cobalt-60 source at doses of 10,15, 20, 40 and 60 megarads (MRad). Several identically prepared but unirradiated strands were also tested. One set of samples at each dose was immersed in a silicone oil bath for one half hour at 128°C and one set was given no post-irradiation thermal treatment. Characterization of the resultant morphologies included differential scanning calorimetry (DSC), birefringence, thermomechanical analysis (TMA), and tensile testing. Results from DSC measurements indicate that initial radiation crosslinking only slightly disrupts the crystal lattice, but on subsequent melting and re crystallization, the chains are unable to recrystallize effectively in their former habit. In all cases, melting point and crystallinity decrease with increasing radiation dose. Birefringence and TMA results indicate that orientation is not disrupted by irradiation. For unannealed samples, Young's modulus increases slightly then levels off while tensile strength and elongation at break increase initially, then drop, For annealed irradiated samples, Young's modulus rises at first, then levels off at higher doses. Tensile strength and elongation at break increase significantly with increasing radiation treatment, then essentially reach constant values at highest doses.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 17 (1977), S. 221-221 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 15 (1975), S. 213-218 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The general properties of a novel process for producing high modulus polyolefins are discussed. The technique is an extrusion drawing involving a crystal-crystal transformation. The principal tests have been made on polyethylene and the guidelines have been established for extending the technique to other polyolefins. The characterization of such materials is extensively discussed, particularly in the light of the concept of continuous crystals.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 17 (1977), S. 535-543 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Dynamic viscosity and elastic modulus for a low molecular weight styrene-butadiene-styrene (SBS) block copolymer ate measured as a function of temperature (80-170°C) and frequency using the eccentric rotating disc geometry. These linear properties are superimposed to yield master curves each of which exhibits two branches below different (critical) reduced frequencies. At lower temperatures, the non-Newtonian behavior characteristic of SBS block copolymers is observed. In contrast, Newtonian response occurs at higher temperatures. As a consequence, plots of the viscoelastic properties vs temperature exhibit discontinuities below the critical frequencies, reflecting a narrow transition at about 142°C. Above this temperature, it is inferred, consistent with the equality of dynamic and steady state viscosities, that the polystyrene (S) blocks, existent in dispersed domains at low temperatures, exceed a critical degree of compatibility with the continuous polybutadiene phase. The activation energies indicate that the S blocks affect the temperature dependence of the dynamic properties in proportion to their presence in an interphase which is assumed to continuously grow in size as temperature is raised to the transition temperature. Below the critical reduced frequencies, it is inferred that S domain disruption may increasingly occur in conjunction with the observed property enhancement due to these domains, relative to the miscible blocks, as reduced frequency is lowered. However, above these frequencies, the presence of frequency-temperature superposition implies that the S domains and the miscible blocks are equivalent in their effects on properties. At still higher reduced frequencies, the domains present at the low temperatures studied are assumed to remain intact, but plateau behavior similar to the response characteristic of homopolymers is observed.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 18 (1978), S. 537-545 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: High density polyethylene has been ultradrawn at 80°C by a novel radial-compression method which involves the gradual buildup of highly-stretched elastic (spandex) filaments around the circumference of a solid polymer cylinder. The sheath of tightly-wound filaments generates a high-radial pressure which forces the polyethylene cylinder to neck down, uniaxially extend, and ultradraw. The physical and mechanical properties of radially-compressed polyethylene of maximum draw ratio, 40-45X, were evaluated and compared with the same polymer ultradrawn in other stress fields. In most physical property categories, the radially-compressed samples are virtually indistinguishable from samples prepared by solid-state extrusion at higher temperature and pressure. The transparency and the maximum tensile modulus, 62 GPa, further confirm the effectiveness of radial compression in achieving ultradraw. An experimental technique for measuring the radial pressure generated by the winding of the highly-stretched elastic filament is presented. The upper-bound pressure in the radial-compression experiments was less than 100 MPa.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 18 (1978), S. 921-922 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 16 (1976), S. 200-203 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: A study has been made on the effects of molecular weight on the physical and mechanical properties of cold-extruded high density polyethylene. Prior data indicate that such ultra-drawn strands contain a significant fraction of extended-chain crystals. Four samples, spanning the molecular weight range of 59,000 to 147,000, were cold-extruded under the same conditions and were examined with respect to their melting point, degree of crystallinity, linear expansion coefficient, Young' modulus, strain to break, and tensile strength. The degree of crystallinity, linear expansion coefficient, and modulus did not change significantly with molecular weight. The melting point, strain to break, and tensile strength do increase with increasing molecular weight. This leads to the conclusion that the amount of extended-chain crystals is invariant with molecular weight. Higher molecular weight polymers are seen as providing a greater number of the chains, thus giving the fiber a higher tensile strength.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 19 (1979), S. 441-449 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Ultra-thin films of high density polyethylene of high orientation have been produced by the recently developed technique of solid state coextrusion. The films were prepared under moderate conditions, without lubricant in continuous lengths by extruding through conical dies of extrusion draw ratio up to 36. This is a draw ratio higher than achievable by conventional solid state extrusion at comparable processing conditions through slit dies. The ultra-thin films of high orientation were transparent and exhibited dead bend. The physical and mechanical properties were evaluated and compared with the properties of the same high density polyethylene extruded through a slit die. The increase in the melt point, crystallinity, tensile modulus, and birefringence indicates that the method is very efficient for the production of ultra-thin and highly oriented films. An experimental technique is also presented for preparing billets of controlled and uniform initial morphology and free of voids.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-06-28
    Description: We present Keplerian orbit solutions for the mutual orbits of 17 transneptunian binary systems (TNBs). For ten of them, the orbit had not previously been known: 60458 2000 CM (sub 114), 119979 2002 WC (sub 19), 160091 2000 OL (sub 67), 160256 2002 PD (sub 149), 469514 2003 QA (sub 91), 469705 Kagara, 508788 2000 CQ (sub 114), 508869 2002 VT (sub 130), 1999 RT (sub 214), and 2002 XH (sub 91). Seven more are systems where the size, shape, and period of the orbit had been published, but new observations have now eliminated the sky plane mirror ambiguity in its orientation: 90482 Orcus, 120347 Salacia-Actaea, 1998 WW (sub 31), 1999 OJ (sub 4), 2000 QL (sub 251), 2001 XR (sub 254), and 2003 TJ (sub 58). The dynamical masses we obtain from TNB mutual orbits can be combined with estimates of the objects' sizes from thermal observations or stellar occultations to estimate their bulk densities. The Kagara system is currently undergoing mutual events in which one component casts its shadow upon the other and/or obstructs the view of the other. Such events provide valuable opportunities for further characterization of the system. Combining our new orbits with previously published orbits yields a sample of 35 binary orbits with known orientations that can provide important clues about the environment in which outer solar system planetesimals formed, as well as their subsequent evolutionary history. Among the relatively tight binaries, with semimajor axes less than about 5 percent of their Hill radii, prograde mutual orbits vastly outnumber retrograde orbits. This imbalance is not attributable to any known observational bias. We suggest that this distribution could be the signature of planetesimal formation through gravitational collapse of local density enhancements such as caused by the streaming instability. Wider binaries, with semimajor axes greater than 5 percent of their Hill radii, are somewhat more evenly distributed between prograde and retrograde orbits, but with mutual orbits that are aligned or anti-aligned with their heliocentric orbits. This pattern could perhaps result from Kozai-Lidov cycles coupled with tidal evolution eliminating high inclination wide binaries.
    Keywords: Astrophysics
    Type: GSFC-E-DAA-TN68830 , Icarus (ISSN 0019-1035) (e-ISSN 1090-2643)
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...