ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • INSTRUMENTATION AND PHOTOGRAPHY  (69)
  • Life and Medical Sciences  (59)
  • 1980-1984  (128)
  • 1970-1974
  • 1890-1899
  • 1984  (128)
Collection
Publisher
Years
  • 1980-1984  (128)
  • 1970-1974
  • 1890-1899
Year
  • 1
    ISSN: 0148-7280
    Keywords: spermatozoa ; flow cytometry ; DNA staining ; nuclear morphology ; ultrastructure ; mammals ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology
    Notes: The morphological and ultrastructural changes that occur during preparation of porcine, bovine, and murine spermatozoa for flow cytometric quantification of the relative DNA content of the X- and Y-chromosome-bearing sperm populations were examined. Ejaculated spermatozoa from the boar and bull were washed using a series of dimethyl sulfoxide (DMSO) solutions prior to fixation, whereas the epididymal mouse spermatozoa were washed only in phosphate-buffered saline (PBS). Spermatozoa from all three species were then fixed in ethanol and processed for fluorochrome staining by a treatment regimen consisting of sulfhydryl reduction and proteolysis. The processed sperm nuclei were stained for DNA with the fluorochrome, 4′-6-diamidino-2-phenylindole (DAPI) before quantification by flow cytometry. Scanning and transmission electron micrographs of sperm heads taken at various steps of the preparation and staining procedures show 1) that the rigorous washing procedure disrupted the plasma and outer acrosomal membranes, 2) that ethanol fixation resulted in removal of the outer membranes and disintegration of the nuclear envelope, and 3) that thiol and proteolysis treatment removed the remaining cellular organelles including the tail and rapidly induced partial decondensation of the tightly packed chromatin. Sequential micrographs showed that the nuclear matrix of all three species increased in thickness about twofold during the preparation and staining. Consequently, the harsh procedures currently used for quantitative staining of DNA for high-resolution flow cytometric analyses destroy most cellular organelles and thereby prevent simultaneous characterization of DNA content and other sperm cell constituents.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-19
    Description: Attention is given to 1.2 years of data from two Michelson-Gale long fluid tiltmeters, one long center pressure tiltmeter, and a shallow borehole tiltmeter, which have been in operation at Pinon Flat Observatory in Southern California. The most stable tilt record shows a secular rate of 0.28 microrad/a, which may be real. Comparisons undertaken among instruments have identified more and less successful measurement techniques. It is concluded that even the best existing sensors must be improved in order to measure continuous tectonic motions.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Geophysical Research Letters (ISSN 0094-8276); 11; 963-966
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2016-06-07
    Description: A redesign of the antenna electronics package for the NBS/GPS C/A receiver has resulted in significantly reduced cost and improved performance. Major improvements include a simplified and more reliable multiplier/mixer, elimination of all twelve piston trimmer tuning capacitors in the original design, elimination of expensive bandpass filters, less expensive antenna and a simplified packaging scheme.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 467-474
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Morphology 180 (1984), S. 29-35 
    ISSN: 0362-2525
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: This study describes intercellular bridges in the ovaries of neonatal gerbils. Electron microscopy has revealed the presence of true intercellular bridges, connecting oogonia or oocytes, in ovaries of newborn gerbils. The cytoplasm of the intercellular channels is similar to that of the connected cells, with mitochondria, smooth and rough endoplasmic reticulum, and free ribosomes present. Lysosomes are also occasionally present in the intercellular bridges and they may be involved in early waves of oocyte atresia. An electrondense substance, 350-500 Å thick, is located immediately beneath the unit membrane of the intercellular bridges. Accumulation of electron-dense material increases the thickness of the walls of the intercellular bridges, supporting and maintaining the patency of the channels. It is suggested that the intercellular channels probably allow the interchange of nutrients, organelles, and possibly regulatory materials as well.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Morphology 180 (1984), S. 243-252 
    ISSN: 0362-2525
    Keywords: Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: A small short muscle frequently acts across a joint in parallel with a vastly larger and longer muscle; therefore it should play a minimal role in the mechanical control of that joint. This study provides evidence suggesting that the small member of such a “parallel muscle combination” (PMC) may serve an important sensory feedback role. The spindle densities of large and small members of PMCs in man and the dog were determined and compared. Epaxial PMCs controlling canine intervertebral joints were dissected and tissue samples were embedded in paraffin, sectioned transversely to the muscles' long axis and, stained with hematoxylin-periodic acid-Schiff (PAS). Representative tissue sections were projected on to stereological grids and the percentage volume of spindles was determined. Data existing in the literature were used to ascertain spindle densities in human PMCs controlling joints in the cervico-occipital region and the extremities. The spindle density for each muscle in a group of PMCs controlling a particular motion was listed, and the mean spindle densities were determined for both the large and the small members of the group. Student's unpaired t test was used to determine the significance of the differences between mean spindle densities. Linear regression was calculated and the data were plotted graphically.In all PMCs examined, the spindle density of the small muscles was significantly higher than that of their large counterparts. It is therefore proposed that the small muscles of PMCs may function as “kinesiological monitors” generating important proprioceptive feedback to the central nervous system.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Journal of Electron Microscopy Technique 1 (1984), S. 299-309 
    ISSN: 0741-0581
    Keywords: Electron microscopy ; Ion microscopy ; Correlative microscopy ; Electron probe microanalysis ; Life and Medical Sciences ; Cell & Developmental Biology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Natural Sciences in General
    Notes: In order to correctly interpret the chemical images obtained using ion microscopy (IM), it is useful to correlate them with the information provided by conventional light microscopy (LM), secondary electron imaging (SEI), backscattered electron imaging (BEI), and electron probe microanalysis (EPMA). Accordingly, we have devised a technique of specimen preparation which allows for the application of several different microanalytical techniques to a single histologic section mounted on the same substrate. Sections are cut onto polyester plastic coverslips (devoid of peaks for any element with atomic number 〉 9 using EPMA) and studied by LM. After a light rotary coating with carbon (to prevent charging), the section can then be examined by SEI, BEI, and EPMA. Specific areas can be marked for IM study either with an objective-mounted pin tissue microlocater, or by placing small pieces of metal foil, cut in specific geometric shapes, over features of interest. After sputter-coating the sample with platinum, metal-free shadows are visible using a low-power reflected light microscope available on a typical IM sample chamber as a guide for ion beam placement. The conductive coatings also minimize specimen charging during IM. Post-IM light microscopy, SEI, and BEI are used to confirm the location of specific areas probed in the IM experiments and to provide information on differential ion-sputtering artifacts and tissue contaminants. This new correlative technique should permit better understanding of the images obtained with these diverse instruments.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 5 (1984), S. 101-112 
    ISSN: 0197-8462
    Keywords: 60-Hz electric fields ; rats ; behavior ; teratology ; growth ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: A series of three experiments was performed to determine the effects of 30-day exposures to uniform 60-Hz electric fields (100 kV/m) on reproduction and on growth and development in the fetuses and offspring of rats. In the first experiment, exposure of females for 6 days prior to and during the mating period did not affect their reproductive performance, and continued exposure through 20 days of gestation (dg) did not affect the viability, size, or morphology of their fetuses. In the second experiment, exposure of the pregnant rat was begun on 0 dg and continued until the resulting offspring reached 8 days of age. In the third experiment, exposure began at 17 dg and continued through 25 days of postnatal life. In the second and third experiments, no statistically significant differences suggesting impairment of the growth or survival of exposed offspring were detected. In the second experiment, a significantly greater percentage of the exposed offspring showed movement, standing, and grooming at 14 days of age than among-sham-exposed offspring. There was a significant decrease at 14 days in the percentage of exposed offspring displaying the righting reflex in the second experiment and negative geotropism in the third experiment. These differences were all transient and were not found when the animals were tested again at 21 days of age. Evaluation of the reproductive integrity of the offspring of the second experiment did not disclose any deficits.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2011-08-18
    Description: A new type of bolometer detector for the millimeter and submillimeter spectral range is described. The bolometer is constructed of silicon using integrated circuit fabrication techniques. Ion implantation is used to give controlled resistance vs temperature properties as well as extremely low 1/f noise contacts. The devices have been tested between 4.2 and 0.3 K. The best electrical NEP measured is 4 x 10 to the -16th W/Hz to the 1/2 at 0.35 K between 1- and 10-Hz modulation frequency. This device had a detecting area of 0.25 sq cm and a time constant of 20 msec at a bath temperature of 0.35 K.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 910-914
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2016-06-07
    Description: The method of ion storage provides a basis for excellent time and frequency standards. This is due to the ability to confine ions for long periods of time without the usual perturbations associated with confinement (e.g., wall shifts). In addition, Doppler effects can be greatly suppressed. The use of stored ions for microwave frequency standards and the future possibilities for an optical frequency standard based on stored ions are addressed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 49-58
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2014-09-13
    Description: A three factor (spectral, spatial, and radiometric resolution), two level (TM and MSS) analysis of variance (ANOVA) approach allowed evaluation of the effects of each factor individually and in all possible combinations. Digital classification accuracy was used as the figure of merit. Nine study sites in Washington, D.C. each of approximately 256 x 256 TM pixels, were randomly selected from the full scene for analysis. These results strongly suggest that the quantization level improvements and the addition of new spectral bands in the visible and middle IR regions (both afforded by the TM sensor design) can result in improved capabilities to accurately delineate land cover categories using a per point Gaussian maximum likelihood classifier. On the other hand, results indicate that the increase in spatial resolution to 30m does not significantly enhance classification accuracy. The spatial result points to an inherent limitation of a per point classifier and to the need to improve data analysis techniques to handle high spatial resolution data.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: LANDSAT-4 Sci. Invest. Summ., Including Dec. 1983 Workshop Results, Vol. 2; p 93-97
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...