ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • INSTRUMENTATION AND PHOTOGRAPHY  (69)
  • 2020-2020
  • 1980-1984  (69)
  • 1984  (69)
  • 1
    Publication Date: 2011-08-19
    Description: Attention is given to 1.2 years of data from two Michelson-Gale long fluid tiltmeters, one long center pressure tiltmeter, and a shallow borehole tiltmeter, which have been in operation at Pinon Flat Observatory in Southern California. The most stable tilt record shows a secular rate of 0.28 microrad/a, which may be real. Comparisons undertaken among instruments have identified more and less successful measurement techniques. It is concluded that even the best existing sensors must be improved in order to measure continuous tectonic motions.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Geophysical Research Letters (ISSN 0094-8276); 11; 963-966
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2016-06-07
    Description: A redesign of the antenna electronics package for the NBS/GPS C/A receiver has resulted in significantly reduced cost and improved performance. Major improvements include a simplified and more reliable multiplier/mixer, elimination of all twelve piston trimmer tuning capacitors in the original design, elimination of expensive bandpass filters, less expensive antenna and a simplified packaging scheme.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 467-474
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-18
    Description: A new type of bolometer detector for the millimeter and submillimeter spectral range is described. The bolometer is constructed of silicon using integrated circuit fabrication techniques. Ion implantation is used to give controlled resistance vs temperature properties as well as extremely low 1/f noise contacts. The devices have been tested between 4.2 and 0.3 K. The best electrical NEP measured is 4 x 10 to the -16th W/Hz to the 1/2 at 0.35 K between 1- and 10-Hz modulation frequency. This device had a detecting area of 0.25 sq cm and a time constant of 20 msec at a bath temperature of 0.35 K.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Optics (ISSN 0003-6935); 23; 910-914
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2016-06-07
    Description: The method of ion storage provides a basis for excellent time and frequency standards. This is due to the ability to confine ions for long periods of time without the usual perturbations associated with confinement (e.g., wall shifts). In addition, Doppler effects can be greatly suppressed. The use of stored ions for microwave frequency standards and the future possibilities for an optical frequency standard based on stored ions are addressed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NASA. Goddard Space Flight Center Proc. of the 16th Ann. Precise Time and Time Interval (PTTI) Appl. and Planning Meeting; p 49-58
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2014-09-13
    Description: A three factor (spectral, spatial, and radiometric resolution), two level (TM and MSS) analysis of variance (ANOVA) approach allowed evaluation of the effects of each factor individually and in all possible combinations. Digital classification accuracy was used as the figure of merit. Nine study sites in Washington, D.C. each of approximately 256 x 256 TM pixels, were randomly selected from the full scene for analysis. These results strongly suggest that the quantization level improvements and the addition of new spectral bands in the visible and middle IR regions (both afforded by the TM sensor design) can result in improved capabilities to accurately delineate land cover categories using a per point Gaussian maximum likelihood classifier. On the other hand, results indicate that the increase in spatial resolution to 30m does not significantly enhance classification accuracy. The spatial result points to an inherent limitation of a per point classifier and to the need to improve data analysis techniques to handle high spatial resolution data.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: LANDSAT-4 Sci. Invest. Summ., Including Dec. 1983 Workshop Results, Vol. 2; p 93-97
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2019-06-28
    Description: A new microbolometer for far-infrared detection has been fabricated that allows an increase in sensitivity of a factor of 4 over the best previously reported bolometer. By suspending the detector in the air above its substrate, a reduction in the thermal conductance out of the device by a factor of 5 has been achieved. At a modulation frequency of 100 kHz this microbolometer has an electrical noise equivalent power 28 pW/sq rt Hz. A thermal model is also presented that accurately fits the response of the detector.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Applied Physics Letters (ISSN 0003-6951); 44; 153-155
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-06-28
    Description: A high sensitivity laser interferometry for continuous monitoring of optical path changes is presented. The sensitivity to small changes in the optical path is achieved by means of a feedback system which keeps the interferometer at its maximum (and linear) position. Two experiments were designed to verify the interferometer's performance, both in direct and in scattering configurations. In each case, small temperature fluctuations were introduced as the signal source. Simultaneous measurement of temperature were compared with the results of the interferometer. Good correlation between the results were obtained. Finally, the application of the high sensitivity interferometer for detection of boundary-layer transition is examined. Optical signal strength and possible sources of noise are examined. Some methods of model surface preparation for enhancement of signal-to-noise ratio are discussed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: AIAA PAPER 84-1540
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    facet.materialart.
    Unknown
    In:  Other Sources
    Publication Date: 2019-06-28
    Description: A technique which allows the measurement of detector embedding impedance has been developed. By using a bismuth microbolometer as a variable resistance load the impedance of one element in a bow-tie antenna array operating at 94 GHz was inferred. The technique is frequency insensitive, and could be used throughout the far-infrared.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: International Journal of Infrared and Millimeter Waves (ISSN 0195-9271); 5; 1017-102
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    facet.materialart.
    Unknown
    In:  CASI
    Publication Date: 2019-06-28
    Description: A sensor for measuring flow direction and airspeed that is suitable, because of its small size, for rapid instrumentation of research airplanes is described. A propeller driven sphere rotating at a speed proportional to airspeed presents a reflective target to an electro-optical system such that the duty cycle of the resulting electrical output is proportional to yaw angle and the frequency is proportional to airspeed.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: NAS 1.71:LAR-13065-1
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-07-13
    Description: Some of the laboratory measured performance parameters of the HRS are reported. Then a description is given of three aspects of performance of particular importance to astronomers: (1) the capability of detecting very weak features against a continuum, (2) the capability of producing reliable line profiles, and (3) the capability of assigning accurate wavelengths to spectral features. Specific technical descriptions of the performance of the HRS detectors (Eck and Beaver, this volume), gratings (Bottema et al., this volume), and control and data-handling system (Becker, this volume) are reported separately.
    Keywords: INSTRUMENTATION AND PHOTOGRAPHY
    Type: Instrumentation in astronomy V; Sep 07, 1983 - Sep 09, 1983; London
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...