ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Years
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of food science 32 (1967), S. 0 
    ISSN: 1750-3841
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A number of sorbic acid derivatives were tested for their ability to limit the growth of food molds, Two derivatives, sorbohydroxamic acid and sorbic aldehyde, were found to be more effective than the parent acid, The undesirable odor and flavor of sorbic aldehyde ruled this compound out as a potential food preservative; however, sorbohydroxamic acid was selected for further testing since it was highly effective, free of undesirable flavor and odor notes, and active over a relatively broad pH range. The effectiveness in vitro of sorbohydroxamic acid was confirmed in food systems. The toxicological aspects of this compound are discussed briefly.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of food science 42 (1977), S. 0 
    ISSN: 1750-3841
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition , Process Engineering, Biotechnology, Nutrition Technology
    Notes: A calibration procedure for the Sina-scope hygrometer is described. Four saturated salt solutions, covering a range from 0.755–0.967aw, and two foods, with a, levels in the intermediate moisture food range, were tested to determine the accuracy and precision of the Sina instrument. Accuracy, relative to averaged published a, levels for the four standard salts, was evaluated. Most measured values were slightly less than the averaged standards. The greatest difference noted was -1.06% of the standard. Estimates of instrument precision showed that the coefficient of variation decreased with measurement of successively higher a, standard solutions and did not exceed 1%. Instrument readings to two decimal places possessed standard deviations slightly lower than corresponding readings estimated to three decimal places. Standard deviations (20 replicates at each aw) ranged from o—0.004. Estimates of pooled, between-sensor standard deviation showed that there were no significant differences between the two sensors used in those studies. Equilibration periods of 45 or 60 min were almost equally precise. The number of replicates required to produce a given level of data confidence are calculated and presented. Similar results relative to estimates of precision were obtained with the two foods tested.
    Type of Medium: Electronic Resource