Publication Date:
2019-05-17
Description:
Optical coherence tomography (OCT) has recently been demonstrated as a powerful tool to image through pharmaceutical film coatings. Majority of the existing systems can, however, resolve film coatings for thickness greater than 10 µm. Here we report on an ultra-high-resolution (UHR) OCT system, with 1 µm axial and 1.6 µm lateral resolutions, which can resolve thin coatings at approximately 4 µm. We further demonstrate a novel application of the system for differentiating generic and branded suppliers of paracetamol tablets.
Electronic ISSN:
2079-6412
Topics:
Chemistry and Pharmacology
,
Process Engineering, Biotechnology, Nutrition Technology