ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1
    Publication Date: 2020-05-24
    Description: The progressive increase in hydrogen technologies’ role in transport, mobility, electrical microgrids, and even in residential applications, as well as in other sectors is expected. However, to achieve it, it is necessary to focus efforts on improving features of hydrogen-based systems, such as efficiency, start-up time, lifespan, and operating power range, among others. A key sector in the development of hydrogen technology is its production, renewable if possible, with the objective to obtain increasingly efficient, lightweight, and durable electrolyzers. For this, scientific works are currently being produced on stacks technology improvement (mainly based on two technologies: polymer electrolyte membrane (PEM) and alkaline) and on the balance of plant (BoP) or the industrial plant (its size depends on the power of the electrolyzer) that runs the stack for its best performance. PEM technology offers distinct advantages, apart from the high cost of its components, its durability that is not yet guaranteed and the availability in the MW range. Therefore, there is an open field of research for achievements in this technology. The two elements to improve are the stacks and BoP, also bearing in mind that improving BoP will positively affect the stack operation. This paper develops the design, implementation, and practical experimentation of a BoP for a medium-size PEM electrolyzer. It is based on the realization of the optimal design of the BoP, paying special attention to the subsystems that comprise it: the power supply subsystem, water management subsystem, hydrogen production subsystem, cooling subsystem, and control subsystem. Based on this, a control logic has been developed that guarantees efficient and safe operation. Experimental results validate the designed control logic in various operating cases, including warning and failure cases. Additionally, the experimental results show the correct operation in the different states of the plant, analyzing the evolution of the hydrogen flow pressure and temperature. The capacity of the developed PEM electrolysis plant is probed regarding its production rate, wide operating power range, reduced pressurization time, and high efficiency.
    Electronic ISSN: 2079-9292
    Topics: Electrical Engineering, Measurement and Control Technology
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2020-10-28
    Description: This article presents a methodological foundation to design and experimentally test a Model Predictive Controller (MPC) to be applied in renewable source-based microgrids with hydrogen as backup. The Model Predictive Controller has been developed with the aim to guarantee the best energy distribution while the microgrid operation is optimized considering both technical and economic parameters. As a differentiating element, this proposal provides a solution to the problem of energy management in real systems, addressing technological challenges such as charge management in topologies with direct battery connection, or loss of performance associated with equipment degradation or the required dynamics in the operation of hydrogen systems. That is, the proposed Model Predictive Controller achieves the optimization of microgrid operation both in the short and in the long-term basis. For this purpose, a generalized multi-objective function has been defined that considers the energy demand, operating costs, system performance as well as the suffered and accumulated degradation by microgrid elements throughout their lifespan. The generality in the definition of the model and cost function, allows multi-objective optimization problems to be raised depending on the application, topology or design criteria to be considered. For this purpose, a heuristic methodology based on artificial intelligence techniques is presented for the tuning of the controller parameters. The Model Predictive Controller has been validated by simulation and experimental tests in a case study, where the performance of the microgrid under energy excess and deficit situations has been tested, considering the constrains defined by the degradation of the systems that make up the microgrid. The designed controller always made it possible to guarantee both the power balance and the optimal energy distribution between systems according to the predefined priority and accumulated degradation, while guaranteeing the maximum operating voltage of the system with a margin of error less than 1%. The simulation and experimental results for the case study showed the validity of the controller and the design methodology used.
    Electronic ISSN: 2071-1050
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2020-04-24
    Description: The growth of the world’s energy demand over recent decades in relation to energy intensity and demography is clear. At the same time, the use of renewable energy sources is pursued to address decarbonization targets, but the stochasticity of renewable energy systems produces an increasing need for management systems to supply such energy volume while guaranteeing, at the same time, the security and reliability of the microgrids. Locally distributed energy storage systems (ESS) may provide the capacity to temporarily decouple production and demand. In this sense, the most implemented ESS in local energy districts are small–medium-scale electrochemical batteries. However, hydrogen systems are viable for storing larger energy quantities thanks to its intrinsic high mass-energy density. To match generation, demand and storage, energy management systems (EMSs) become crucial. This paper compares two strategies for an energy management system based on hydrogen-priority vs. battery-priority for the operation of a hybrid renewable microgrid. The overall performance of the two mentioned strategies is compared in the long-term operation via a set of evaluation parameters defined by the unmet load, storage efficiency, operating hours and cumulative energy. The results show that the hydrogen-priority strategy allows the microgrid to be led towards island operation because it saves a higher amount of energy, while the battery-priority strategy reduces the energy efficiency in the storage round trip. The main contribution of this work lies in the demonstration that conventional EMS for microgrids’ operation based on battery-priority strategy should turn into hydrogen-priority to keep the reliability and independence of the microgrid in the long-term operation.
    Electronic ISSN: 2079-9292
    Topics: Electrical Engineering, Measurement and Control Technology
    Location Call Number Expected Availability
    BibTip Others were also interested in ...