ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0197-8462
    Keywords: radiofrequency radiation ; heart rate ; blood pressure ; cardiovascular system ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Exposure to fast-rise-time ultra-wideband (UWB) electromagnetic pulses has been postulated to result in effects on biological tissue (including the cardiovascular system). In the current study, 10 anesthetized Sprague-Dawley rats were exposed to pulses produced by a Sandia UWB pulse generator (average values of exposures over three different pulse repetition rates: rise time, 174-218 ps; peak E field, 87-104 kV/m; pulse duration, 0.97-0.99 ns). Exposures to 50, 500 and 1000 pulses/s resulted in no significant changes in heart rate or mean arterial blood pressure measured every 30 s during 2 min of exposure and for 2 min after the exposure. The results suggest that acute UWB whole-body exposure under these conditions does not have an immediate detrimental effect on these cardiovascular system variables in anesthetized rats. Bioelectromagnetics 19:330-333, 1998. Published 1998 Wiley-Liss, Inc.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 13 (1992), S. 323-328 
    ISSN: 0197-8462
    Keywords: behavior ; motion response ; sensory ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Single, 1.25-GHz microwave pulses of 0.8- to 1.0-μs duration were presented to each of four rats 100 ms before presentation of a startle-inducing acoustic stimulus. This sequential pairing of microwave pulse and acoustic stimulus was found to modify the startle response. At an energy dose to the head of 22-43 mJ/kg per pulse (peak SAR, 23-48 kW/kg), the mean latency to the startle response was longer and the mean amplitude of the response was smaller with respect to control responses that occurred to acoustic stimuli alone. However, at a higher energy dose per microwave pulse in the range of 59-107 mJ/kg (peak SAR, 63-111 kW/kg), the mean latency and amplitude of the startle response were not statistically different from the respective means of control responses. 1992 Wiley-Liss, Inc.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 14 (1993), S. 41-55 
    ISSN: 0197-8462
    Keywords: continuous-wave ; pulse modulation ; chicken embryo ; tissue culture ; square-wave modulation ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Inter-beat intervals of aggregated cardiac cells from chicken embryos were studied during 190 s exposures to 2.45 GHz microwaves in an open-ended coaxial device. Averaged specific-absorption rates (SARs) and modulation conditions were 1.2-86.9 W/kg continuous-wave (CW). 1.2-12.2 W/kg pulse modulation (PW, duty cycle ∽ 11%). and 12.0-43.5 W/kg square-wave modulation (duty cycle = 50%). The inter-beat interval decreased during microwave exposures at 42.0 W/kg and higher when CW or square-wave modulation was used, which is consistent with established effects of elevated temperatures. However, increases in the inter-beat interval during CW exposures at 1.2-12.2 W/kg, and decreases in the inter-beat interval after PW exposures at 8.4-12.2 W/kg. are not consistent with simple thermal effects. Analysis of variance indicated that SAR. modulation, and the modulation-SAR interaction were all significant factors in altering the interbeat interval. The latter two factors indicated that the cardiac cells were affected by athermal as well as thermal effects of microwave exposure. © 1993 Wiley-Liss. Inc.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Bioelectromagnetics 10 (1989), S. 147-160 
    ISSN: 0197-8462
    Keywords: microwave hearing ; auditory unit ; characteristic frequency ; Life and Medical Sciences ; Occupational Health and Environmental Toxicology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Physics
    Notes: Action potentials of neurons in cat dorsal and posteroventral cochlear nuclei were recorded extracellularly with glass microelectrodes while the head of the cat was exposed to microwave pulses at 915 MHz using a diathermy applicator. Response thresholds to acoustic tones, acoustic clicks, and microwave pulses were determined for auditory units with characteristic frequencies (CFs) from 278 Hz to 39.2 kHz. Tests with pulsatile stimuli were performed for durations of 20-700 μs, principally 20, 70, and 200 μs. Brainstem midline specific absorption rate (SAR) threshold was as small as 11.1 mW/g per pulse, and specific absorption (SA) threshold was as small as 0.6 μJ/g per pulse. Microwave thresholds were generally lower for CF less than 9 kHz, as were most acoustic thresholds. However, microwave threshold was only weakly related to click threshold and CF-tone threshold of each unit.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 1977-11-01
    Print ISSN: 0048-6604
    Electronic ISSN: 1944-799X
    Topics: Geosciences , Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...